8 Fiber MPO / MTP Rau 4 × LC Duplex UPC OM4 Breakout Cable

Xa kev nug
8 Fiber MPO / MTP Rau 4 × LC Duplex UPC OM4 Breakout Cable
Paub meej
8-fiber OM4 MPO rau 4 × LC duplex breakout cable rau tshaj 40G SR4 rau 4 × 10G thiab 100G SR4 rau 4 × 25G txuas. Kev cai polarity thiab ntev.
Kev faib tawm yam khoom
MTP MPO Fiber Breakout Cable
Share to
Hauj lwm lawm

Product Overview

 

8 fiber MPO to 4 LC duplex OM4 breakout cable

DIMI 8 Fiber MPO / MTP rau 4 × LC Duplex UPC OM4 Breakout Cable cais ib qho kev sib txuas-optics rau hauv plaub qhov txuas LC duplex.

Nws yog npaj rau cov khoom siv-sab breakout qhov twg MPO / MTP SR4 interface xav tau txuas mus rau plaub qhov chaw kho qhov muag duplex, suav nrog 40GBASE-SR4 rau 4 × 10GBASE-SR thiab 100GBASE-SR4 rau 4 × 25GBASE-SR txuas.

Lub rooj sib txoos siv yim OM active 4 50/125 μm fibers. MPO / MTP connector hom, poj niam los txiv neej, polarity, lub ntsiab cable ntev, LC fanout ntev, lub tsho thiab ceg taw qhia tau teev raws li cov khoom siv txuas.

Active Fiber suav:8 Fibers

Kev tawg:4 × LC Duplex

Fiber ntau:OM 4 50/125 μm Multimode

LC Polish:UPC

Polarity:Hom B / Yuav Tsum Tau Xaus-rau-End Mapping

Common Application:Tau tshaj SR4 Chaw nres nkoj Breakout

Xa lus nug tam sim no

 

Qhov no Breakout Cable puas ua haujlwm nrog koj cov khoom siv?

 

Cov kab no yog tsim los rau cov chaw sib txuas-optics uas nthuav tawm plaub txoj kev ywj pheej thiab tau txais txoj kab. Cov kev sib txuas sib txuas, NIC thiab transceiver yuav tsum txhawb nqa qhov xav tau kev sib cais.

Ib qho 40G multimode breakout yog:

40G QSFP + SR4 → MPO/MTP → 4 × LC Duplex → 4 × 10G SFP + SR

Ib qho 100G multimode breakout yog:

100G QSFP28 SR4 → MPO/MTP → 4 × LC Duplex → 4 × 25G SFP28 SR

Lub cable tsis tsim breakout peev xwm ntawm nws tus kheej. Tus tswv tsev chaw nres nkoj yuav tsum txhawb nqa kev ua haujlwm channel, thiab optics ntawm ob qho kawg yuav tsum siv txoj kab sib txuas thiab fiber ntau architectures.

Duplex optics xws li LR4, CWDM4 thiab lwm cov wavelength-multiplexed modules siv cov kev sib txawv ntawm qhov sib txawv thiab yuav tsum tsis txhob xav tias sib haum nrog SR4-style MPO-to-LC breakout.

QSFP SR4 MPO to 4 LC breakout connection

 

 

Xyuas cov khoom no ua ntej xaj

 

 

Tshawb xyuas Vim Li Cas Nws Tseem Ceeb
Hloov / NIC Breakout Txhawb Qhov chaw nres nkoj siab ceev yuav tsum txhawb nqa 4-txoj kab breakout lossis channelization.
High-Speed ​​Transceiver Paub meej tias cov module siv cov khoom sib txuas xws li SR4.
MPO/MTP interface Paub meej tias lub cev txuas, cov neeg fiber ntau, poj niam txiv neej thiab kev taw qhia tseem ceeb.
LC-Side Optics Paub meej tias plaub qhov chaw transceivers siv tau tshaj duplex multimode txuas.
Polarity Tx thiab Rx fiber ntau txoj haujlwm yuav tsum sib phim thoob plaws hauv qhov ua tiav qhov kho qhov muag channel.
Hom Fiber OM4 multimode fiber ntau yuav tsum phim cov ntsia multimode optics thiab cabling.
Cable & Fanout Length Ntev yuav tsum phim txoj kev khib nyiab tiag tiag thiab cov khoom siv-chaw nres nkoj sib nrug.

 

 

Technical Specifications

 

 

Yam khoom MPO/MTP rau LC Breakout Harness
Active Fiber suav 8 Fibers
Breakout Configuration 4 × LC Duplex
Hom Fiber OM4 Multimode 50/125 μm
MPO/MTP Sab Parallel-Optics MPO/MTP Interface, 8 Active Fibers
LC Sab 4 × LC Duplex UPC
Ua haujlwm Wavelength 850 nm / 1300 nm
Polarity Hom B / Project-Specific Mapping
Connector Poj Niam Txiv Neej Raws li xav tau Interface
Jacket Options LSZH/OFNP
Jacket Xim Magenta / Custom
Main Cable Length Kev cai
LC Fanout Length Kev cai
Ceg Identification LC01-LC04 / Custom Labels

 

8-Fiber Breakout Structure & Polarity

 

Ib qho SR4 txuas siv plaub txoj kab xa tawm thiab plaub txoj kab tau txais. Lub breakout harness cais yim active fibers rau hauv plaub LC duplex ceg.

Txhua ceg LC duplex dhau los ua ib qho kev ywj pheej ob-fiber optical txoj kev mus rau qhov qis-ceev transceiver.

Active Fibers: 8

Parallel Optical Lanes: 4

LC Duplex Links: 4

Lub cev MPO / MTP connector yuav tsum raug xaiv raws li lub transceiver thiab nruab cabling system. Ntau lub SR4 modules siv MPO-12 interface nrog yim txoj haujlwm fiber ntau, thaum Base-8 cabling systems yuav siv 8-fiber MPO / MTP hom.

8 fiber MPO to 4 LC duplex breakout structure

 

MPO to 4 LC duplex polarity diagram

Tsis txhob xaiv polarity los ntawm lub npe Cable ib leeg

Hom B feem ntau yog siv rau qhov sib txuas-optics breakout txuas, tab sis qhov tseeb Tx / Rx mapping nyob ntawm qhov ua tiav channel.

Connector tseem ceeb orientation, MPO / MTP poj niam los yog pinning, adapters, thaj panels thiab cov kev sib txuas transceivers tag nrho cov cuam tshuam rau qhov yuav tsum tau daim ntawv qhia.

Yog hais tias cov cabling polarity uas twb muaj lawm tsis paub, muab tus qauv hloov, transceiver ib feem ntawm tus lej lossis daim duab sib txuas yooj yim ua ntej tsim khoom.

 

Common Breakout Applications

 

Cov piv txwv no tsuas yog siv thaum cov chaw nres nkoj sib txuas thiab cov transceivers txhawb nqa cov qauv sib txuas sib txuas.
40G SR4 to 4x10G MPO breakout
40G Sib
40G SR4 rau 4 × 10G SR
Txuas 40G QSFP + SR4 chaw nres nkoj mus rau plaub qhov kev ywj pheej 10G SFP + SR kho qhov muag txuas.
100G SR4 to 4x25G MPO breakout
100G Breakout
100G SR4 rau 4 × 25G SR
Txuas lub 100G QSFP28 SR4 chaw nres nkoj rau plaub qhov kev ywj pheej 25G SFP28 SR kho qhov muag txuas.
MPO to LC breakout cable in data center rack
Khoom siv Fanout
Rack-Level MPO-rau-LC
Ntxuam tawm ib qho sib luag MPO / MTP interface rau plaub qhov chaw nyob ze LC duplex hauv ib lub khib lossis cov khoom siv nyob ib sab.

 

 

Configuration Information for Quotation

 

 

Cov ntaub ntawv Yuav muab dab tsi
Hloov / NIC Qauv los yog Port Information
High-Speed ​​Optic QSFP + / QSFP28 Transceiver Tshooj Naj Npawb
LC-Side Optics SFP+ / SFP28 Transceiver Part Number
MPO/MTP interface Connector Hom thiab poj niam txiv neej
Polarity Hom B los yog Yuav Tsum Tau Daim Ntawv Qhia Kawg-rau-End
Cable Ntev Yuav tsum tau Main Cable Length
Fanout Length Yuav tsum tau LC ceg Length
Jacket LSZH/OFNP
Ceg Labels LC01-LC04 / Kev Cai
Ntau Qhov project Quantity

Xa koj Cable Specification

 

FAQ

 

Q: Cov kab no puas tuaj yeem siv rau 40G rau 4 × 10G breakout?

A: Yog lawm, thaum lub 40G chaw nres nkoj siv sib xws thaum uas tig mus 40GBASE-SR4 optics thiab qhov hloov pauv tau txhawb nqa plaub txoj kab tawg. Plaub ceg LC tuaj yeem txuas mus rau 10GBASE-SR optics.

Q: Nws puas tuaj yeem siv rau 100G rau 4 × 25G breakout?

A: Yog lawm, qhov sib txuas ntawm 100GBASE-SR4 QSFP28 tuaj yeem tawg mus rau plaub qhov txuas 25GBASE-SR SFP28 thaum lub chaw nres nkoj host txhawb qhov xav tau 4 × 25G breakout hom.

Q: Puas yog txhua 40G lossis 100G optical module txhawb qhov kev tawm tsam no?

A: Tsis yog. Lub transceiver yuav tsum siv qhov sib npaug-kab kab sib txuas. Modules uas siv duplex LC wavelength multiplexing, piv txwv li, tsis siv tib txoj kev MPO-to-4 × LC breakout.

Q: Kuv puas xav tau 8-fiber MPO lossis MPO-12 connector?

A: SR4 txuas siv yim fibers nquag, tab sis lub cev sib txuas hom nyob ntawm qhov kho qhov muag module thiab cabling system. Ntau QSFP + thiab QSFP28 SR4 transceivers siv MPO-12 interface nrog yim txoj haujlwm nquag, thaum Base-8 cabling systems yuav siv 8-fiber MPO / MTP hom. Paub meej cov khoom siv interface ua ntej xaj.

Q: Yam polarity kuv yuav tsum xaj?

A: Hom B yog ib txwm nyob rau hauv parallel-optics breakout links, tab sis qhov tseeb daim ntawv qhia nyob ntawm tag nrho cov channel. Paub meej tias MPO/MTP orientation, poj niam los txiv neej, adapters thiab cov kev sib txuas optics ua ntej ua tiav cov cable.

 

Related MPO/MTP Resources

 

MPO breakout cable data center resources

MTP MPO Fiber Breakout Cable- Sib piv MPO-to-LC thiab MPO-rau-MPO breakout configurations.

MPO Breakout Cable Qhia- Kev suav fiber ntau, polarity, MPO poj niam txiv neej thiab kev xaiv cov ceg tawv.

16 Fiber ntau MPO-16 rau 8 × LC Duplex OM4 Breakout Cable- Ntau dua-fiber-count MPO-rau-LC breakout configuration rau lwm yam parallel-optics architectures.

MPO Data Center Cabling Design Guide- Npaj fiber ntau suav, connector hom thiab MPO cabling architecture rau kev sib txuas ceev.

 

 

Xav tau MPO-rau-4 × LC Breakout Cable rau Koj Cov Khoom Siv?

 

 

Custom 8 fiber MPO to 4 LC duplex OM4 cable

Xa cov hloov lossis NIC qauv, tus lej transceiver, MPO / MTP interface, xav tau polarity, cable ntev, LC fanout ntev, lub tsho thiab kom muaj nuj nqis.

Yog tias qhov kev teeb tsa breakout tseem tsis tau lees paub, suav nrog qhov chaw nres nkoj siab ceev thiab plaub lub hom phiaj optics yog li cov qauv txuas thiab fiber ntau tuaj yeem kuaj xyuas ua ntej ntau lawm.

Thov ib daim Quote

Cim npe nrov: 8 fiber ntau mpo / mtp rau 4 × lc duplex upc om4 breakout cable, 8 fiber ntau mpo / mtp rau 4 × lc duplex upc om4 breakout cable chaw tsim tshuaj paus, 8 fiber ntau mpo / mtp rau 4 × lc duplex upc om4 breakout cable tsum, 8 fiber mpo

Xa kev nug