Kev xaiv ntawm QSFP28, QSFP-DD thiab OSFP tsis yog ib qho teeb meem ntawm kev sib piv ib daim ntawv rau ib qho Ethernet ceev. QSFP28 tseem yog qhov kev xaiv zoo rau tsim 100G tes hauj lwm. QSFP-DD txuas ntxiv QSFP tsev neeg mus rau 400G, 800G thiab 1.6T- tiam neeg thaum khaws cia rov qab-txoj kev siv tshuab siv tau rau QSFP laus- tsev neeg modules. OSFP yog qhov sib cais yim- txoj kab kev siv los ntawm ntau qhov siab -bandwidth hloov platform, suav nrog cov tshuab tsim rau AI thiab HPC kev sib txuas.
Txoj kev xaiv yog nyob ntawm ntau tshaj li daim ntawv lo module. Koj yuav tsum ntsuas qhov hloov chaw nres nkoj, tus tswv tsev hluav taws xob interface, optical PMD, fiber ntau hom, connector, FEC, breakout hom, module fais fab, cua txias tsim thiab tus neeg muag khoom tsim nyog raws li ib tug system.

QSFP-DD vs QSFP28 vs OSFP
| Lus nug | QSFP28 | QSFP-DD Tsev Neeg | OSFP Family |
|---|---|---|---|
| Qhov laj thawj rau xaiv nws | Khaws lossis nthuav 100G network uas twb muaj lawm | Txav mus rau QSFP-raws li platform mus rau 400G, 800G lossis 1.6T thaum tuav QSFP- tsev neeg tsiv teb tsaws yooj yim | Siv cov qauv tsim nyog uas yuav tsum tau ua los ntawm qhov siab -bandwidth platform, tshwj xeeb tshaj yog qhov chaw uas tus tswv tsev tsim los ntawm OSFP thermal thiab mechanical architecture |
| High -kev ceev hluav taws xob txoj kab tsheb ciav hlau | Plaub- txoj kab QSFP architecture | Yim - txoj kab hluav taws xob ceev ceev | Yim - txoj kab hluav taws xob ceev ceev |
| Ntau tiam neeg bandwidth | 100G | 400G, 800G thiab 1.6T- tiam neeg | 400G, 800G thiab 1.6T- tiam neeg |
| QSFP-tsev neeg rov qab sib raug zoo | Tsis siv tau raws li tus tswv tsev tshiab tshiab | Tsim los khaws cia rov qab sib raug zoo nrog QSFP-tsev neeg modules, raws li tus tswv tsev txhawb nqa | Tsis muaj ib haiv neeg tib yam -cage QSFP compatibility; adapter-raws li kev tsiv teb tsaws yog nyob ntawm lub platform |
| Kev tswj hwm | Feem ntau cuam tshuam nrog SFF-8636 hauv 4-txoj kab QSFP ib puag ncig | CMIS-raws li QSFP-DD tiam | CMIS-raws li |
| Qhov zoo tshaj plaws thawj lo lus nug | Puas yog 100G tseem ua tau raws li qhov xav tau txuas? | Puas yog lub hom phiaj hloov siv QSFP-DD, thiab koj puas muaj nuj nqis QSFP- tsev neeg tsiv teb tsaws yooj yim? | Puas yog lub hom phiaj hloov lossis AI / HPC platform siv OSFP? |
Luv version:nyob nrog QSFP28 thaum 100G tseem txaus. Xaiv QSFP-DD thaum lub hom phiaj hloov pauv siv QSFP-DD ecosystem thiab tsiv teb tsaws los ntawm QSFP infrastructure tseem ceeb. Xaiv OSFP thaum xaiv qhov hloov pauv, accelerator ntaub lossis network architecture tsim nyob ib puag ncig OSFP. Rau 400G thiab 800G, qhov hloov pauv platform feem ntau txiav txim siab tus tswv tsev - sab hauv daim ntawv ua ntej lub transceiver ua.
Dab tsi yog qhov Transceiver Form Factor Tiag tiag?
Ntau qhov kev sib raug zoo tsis raug pib los ntawm kev kho cov qauv, cov khoom siv hluav taws xob sib txuas thiab cov khoom siv kho qhov muag zoo ib yam. Lawv yog nyias txheej.
Form Factor
QSFP28, QSFP-DD thiab OSFP piav qhia txog lub cev module thiab host-interface architectures. Lawv cov kev qhia tshwj xeeb npog thaj chaw xws li module mechanics, tawb thiab connector tsim, host hluav taws xob tiv tauj, qis-ceev teeb liab, thermal xav tau thiab kev tswj tus cwj pwm.
Daim ntawv foos tsis txhais tau tias txhua qhov ua tau fiber ntau -sab optical interface uas tuaj yeem tsim hauv lub module. CovQSFP-DD MSA cov ntawv qhia tshwj xeeb, piv txwv li, txhais lub pluggable hardware architecture thaum sab nraud kho qhov muag thiab tooj liab lub cev - txheej txheem tshwj xeeb yog tswj hwm los ntawm cov qauv Ethernet thiab lwm yam kev qhia tshwj xeeb.
Tswv Cuab Hluav Taws Xob Interface
Tus tswv tsev hluav taws xob interface piav qhia txog yuav ua li cas cov ntaub ntawv txav ntawm qhov hloov ASIC thiab pluggable module. Txoj kab suav thiab txoj kab tus nqi tseem ceeb ntawm no. QSFP28 zoo sib xws nrog plaub - txoj kab kev siv rau 100G. QSFP-DD thiab OSFP siv yim lub siab- txoj kab hluav taws xob ceev thiab tau hloov zuj zus los ntawm kev tsim hluav taws xob txuas ntxiv.
Yog xav paub ntxiv txog yuav ua li cas QSFP-DD tsev neeg ntsuas nws tus tswv tsev- sab interface, saibQSFP-DD technical overview.
Optical PMD
Qhov kho qhov muag PMD txhais tau tias muaj dab tsi tshwm sim ntawm sab fiber ntau, suav nrog kev kho qhov muag kab, kev npaj wavelength, ncav cuag thiab fiber ntau. Piv txwv suav nrog DR thiab FR tsev neeg. IEEE Ethernet specifications txhais PMDs ntawm nws tus kheej los ntawm cov khoom siv tshuab; tusIEEE 802.3cu saib, piv txwv li, piav qhia txog 400GBASE-FR4 thiab 400GBASE-LR4-6 ua optical PHYs hla ib hom fiber ntau.
Qhov kev sib cais ntawd yog vim li cas ob lub transceivers nyob rau hauv sib txawv host -sab daim ntawv tej zaum yuav sib txuas lus nyob rau tib lub fiber txuas thaum lawv siv tau tshaj optical interfaces.
Fiber Connector thiab Cable
Kev xaiv Connector yog lwm qhov hloov pauv ywj pheej. Nyob ntawm qhov kev siv kho qhov muag, ib qho module yuav siv duplex LC, MPO / MTP lossis lwm qhov txuas. Ib daim ntawv -factor name ib leeg yog li tsis qhia koj seb cov kab txuas txuas puas tuaj yeem rov siv dua.
Thaum parallel optics koom nrog, covMPO / MTP fiber ntau cable tsev neegtshwj xeeb tshaj yog muaj feem xyuam vim hais tias fiber ntau suav, polarity thiab breakout architecture yuav hloov thaum lub sij hawm ib tug 100G- mus rau -400G los yog 400G-rau-800G tsiv teb tsaws.
QSFP28 yog dab tsi thiab thaum twg Nws tseem ua tau zoo?
QSFP28 belongs rau plaub- txoj kab QSFP tsev neeg thiab tau dhau los ua tus qauv tseem ceeb rau 100 Gigabit Ethernet. SNIA cov ntaub ntawv QSFP tam sim no tseem sau QSFP28 hauv 25G-ib- txoj kab QSFP tiam, thaumSWB-8636tseem yog kev tswj hwm -interface specification rau 4-kab modules thiab cables.
Nws qhov txiaj ntsig loj tshaj plaws niaj hnub no tsis yog yav tom ntej bandwidth scaling. Nws yog qhov loj thiab loj hlob ntawm lub teeb 100G ecosystem. Ntau lub lag luam, kev sib txuas lus thiab cov chaw zov me nyuam twb muaj QSFP28 hloov chaw nres nkoj, 100G optics, DACs, AOCs, duplex ib zaug - hom txuas thiab MPO / MTP cabling.
Yog tias 100G tseem txaus siab rau qhov txuas pob nyiaj siv thiab cov kev xav tau ntawm kev khiav tsheb, hloov QSFP28 nkaus xwb vim tias 400G lossis 800G daim ntawv muaj peev xwm yuav ntxiv tus nqi yam tsis tau txhim kho lub network. Qhov kev txiav txim siab hloov pauv thaum uplinks, kab laug sab txuas, cia cov ntaub los yog AI-fab txoj kev xav tau ntau bandwidth rau ib qhov chaw nres nkoj.
QSFP -DD yog dab tsi?
QSFP-DD stands for Quad Small Form Factor Pluggable Double Density. Lub tswv yim "ob chav ceev" yog hais txog tus tswv tsev hluav taws xob sib txuas: piv nrog rau plaub ib txwm - kab QSFP architecture, QSFP-DD ntxiv lwm kab ntawm kev sib cuag thiab txhawb yim siab - txoj kab hluav taws xob ceev.
Tam sim noQSFP-DD Hardware Specification Rev 7.1npog QSFP-DD, QSFP-DD800 thiab QSFP-DD1600. Hauv qhov tshwj xeeb ntawd, tsev neeg ntsuas los ntawm 50G-chav hluav taws xob txoj kab mus txog 100G-chav kawm thiab 200G-chav kawm txoj kab, tso cai rau cov tswv cuab sib sau ua ke-sab bandwidth kom txuas mus txog 400G, 800G thiab 1.6T{15}} tiam
Vim li cas QSFP-DD Backward Compatibility Matters
Backward compatibility yog ib qho ntawm cov lag luam tseem ceeb sib txawv ntawm QSFP-DD thiab ib daim ntawv sib cais tag nrho-factor ecosystem. QSFP-DD MSA hais tias lub tawb thiab cov khoom txuas txuas tau tsim los ua kom tau raws li QSFP yav dhau los- tsev neeg modules. QSFP-DD1600 kuj tau teev tseg raws li rov qab sib xws rau 8- txoj kab QSFP-DD thiab 4-kab QSFP tiam ntawm qib kho vajtse.
Qhov ntawd tuaj yeem ua rau kev hloov pauv hauv lub network yooj yim dua. Ib qho tshiab QSFP-DD hloov tuaj yeem ua haujlwm tau xaiv cov chaw nres nkoj nrog qis dua -ceev QSFP- tsev neeg modules thaum lwm cov chaw nres nkoj txav mus rau ntau dua bandwidth.
Txawm li cas los xij, mechanical insertion tsuas yog thawj tus mob. Lub hauv paus hloov pauv yuav tsum tseem txhawb nqa qhov kev thov chaw nres nkoj ceev, hom kab hluav taws xob, firmware, FEC, kev teeb tsa kev teeb tsa thiab hom module. Ib lub cev sib xws module tseem tuaj yeem ua haujlwm tsis tau.
OSFP yog dab tsi?
OSFP stands rau Octal Small Form Factor Pluggable. "Octal" yog hais txog yim - txoj kab hluav taws xob ceev ceev. Tam sim noOSFP MSA specification librarysuav nrog OSFP, OSFP800 thiab OSFP1600 tiam nrog rau kev caij tsheb sib xws -heatsink variants.
OSFP MSA piav qhia txog 400G-chav ua haujlwm nrog yim 50G-chav kawm txoj kab hluav taws xob, 800G-chav ua haujlwm nrog yim 100G-chav kawm txoj kab thiab 1.6T-chav ua haujlwm nrog yim 200G-chav txoj kab. Qhov tseeb tshwj xeeb tseem kho cov qauv thermal ua ib feem ntawm daim ntawv -factor architecture es tsis yog qhov kev xav tom qab.
OSFP Thermal Variants
OSFP yuav tsum tsis txhob raug kho raws li ib qho kev tsim kom txias txias. Cov kev qhia tshwj xeeb tam sim no suav nrog kev sib xyaw ua ke -heatsink versions thiab OSFP-RHS variants uas nyob ntawm lub caij heatsink muab los ntawm tus tswv tsev. Qhov no ua rau cov chav thermal cuam tshuam ua tiav kev sib xyaw ua ke ntawm module, tawb, heatsink, airflow thiab hloov chassis.
Cov ntsiab lus ntawd pom nyob rau hauv AI thiab HPC systems tam sim no. NVIDIA's officialLinkX 100G-PAM4 cov ntaub ntawv, piv txwv li, piav qhia ntau yam OSFP cov kev siv uas siv nyob rau hauv siab - kev sib hloov ceev thiab kev sib txuas ceev ceev, nrog rau kev sib txawv ntawm kev sib koom ua ke - thiab caij tsheb - heatsink npaj. Qhov no yog ib qho piv txwv ntawm lub platform, tsis muaj pov thawj tias OSFP yog qhov kev xaiv zoo dua thermal hauv txhua qhov tsim.
QSFP-DD vs OSFP Compatibility: Dab tsi tuaj yeem ua haujlwm ua ke?
"Compatible" txhais tau tias tsawg kawg yog plaub yam sib txawv: lub module haum rau mechanically, tus tswv tsev lees paub nws, hom hluav taws xob tau txais kev txhawb nqa, los yog cov khoom siv kho qhov muag ntawm ob qhov kawg tuaj yeem tsim qhov txuas. Cov lus nug no yuav tsum tau txheeb xyuas nyias.

QSFP28 Module puas tuaj yeem txuas rau QSFP-DD Chaw nres nkoj?
Los ntawm kev xav txog kho vajtse kho vajtse, yog: QSFP-DD tau tsim los lees txais QSFP yav dhau los-tsev neeg cov qauv hauv QSFP tsim tsim nyog-DD tawb thiab cov khoom sib txuas.
Kev txhawb nqa kev ua haujlwm tseem yog nyob ntawm lub platform. Ua ntej xa mus, paub meej tias qhov hloov pauv txhawb qhov cuam tshuam txog 100G chaw nres nkoj hom, qhov tshwj xeeb transceiver lossis cable hom, qhov xav tau FEC thiab cov software tso tawm raug siv.
QSFP puas tuaj yeem-DD Module ntsaws rau hauv QSFP28 Chaw nres nkoj?
Tsis yog. Ib tus tswv tsev ib txwm muaj QSFP28 tsis muab QSFP txuas ntxiv -DD kev tiv tauj thiab yim- txoj kab kev sib tham. Backward compatibility feem ntau tau txais txiaj ntsig tshiab QSFP-DD hosts siv QSFP yav dhau los-tsev neeg modules, tsis yog kev taw qhia rov qab.
QSFP Modules puas tuaj yeem siv hauv OSFP Ports?
Tsis ncaj qha los ntawm haiv neeg tib yam -cage compatibility vim OSFP thiab QSFP siv sib txawv mechanical interfaces.
Adapter-raws li kev tsiv teb tsaws muaj nyob hauv qee qhov chaw, tab sis nws yuav tsum tau ua tib zoo saib xyuas. CovOSFP MSA nplooj ntawv sivsau npe thib peb -party OSFP-rau-QSFP adapter piv txwv thaum hais meej meej tias MSA tsis pom zoo lossis lav qhov thib peb cov khoom siv {- tog. Txawm hais tias tus adapter siv tau yog li ntawd nyob ntawm qhov hloov pauv, hom chaw nres nkoj, module, lub zog, cua txias thiab cov khoom tsim nyog.
QSFP puas tuaj yeem-DD thiab OSFP Transceivers Sib Txuas Sib Txuas?
Muaj peev xwm, yog. QSFP-DD module tsis tuaj yeem muab tso rau hauv OSFP tawb, thiab OSFP module tsis tuaj yeem muab tso rau hauv QSFP-DD tawb. Tab sis ob qhov kawg ntawm qhov txuas kho qhov muag tsis xav tau tib lub tswv tsev - sab pob yog tias ob qho tib si transceivers siv cov fiber ntau sib xws - sab interfaces thiab tau txais kev txhawb nqa los ntawm lawv cov keyboards hauv zos.
Rau ib qho sib xyaw -form-factor link, txheeb xyuas:
- Ethernet lossis raws tu qauv tus nqi
- Optical PMD
- wavelength txoj kev npaj
- kho qhov muag kab
- xa thiab tau txais kev txwv optical
- FEC cov cai
- hom fiber ntau
- connector thiab polarity
- local hloov kev tsim nyog ntawm ob qho kawg
Daim ntawv lub cev-factor compatibility thiab optical link interoperability yog cov lus nug sib txawv.Qhov kev sib txawv ntawd yog qhov tseem ceeb thaum sib piv QSFP-DD vs OSFP compatibility.
QSFP28 vs QSFP-DD vs OSFP Electrical Lane Architecture
| Form Factor Family | Lub Tuam Txhab Hluav Taws Xob | Common Generation Association | Lub ntsiab lus |
|---|---|---|---|
| QSFP28 | 4 | 100G | Mature 100G architecture nrog lub hauv paus loj |
| QSFP-DD | 8 | 400G, 800G, 1.6T-chav kawm | Txuas QSFP cov neeg kho tshuab tsev neeg nrog rau kab thib ob ntawm kev sib cuag thiab ntau dua tus tswv tsev bandwidth |
| OSFP | 8 | 400G, 800G, 1.6T-chav kawm | Cais yim-kab txoj kab uas siv los ntawm tus tswv platforms tsim nyob ib ncig ntawm OSFP txhua yam thiab thermal ecosystem |
Tsis txhob suav Ethernet ceev los ntawm lub npe pob ib leeg. QSFP-DD thiab OSFP ob qho tib si ncua ntau tiam neeg hluav taws xob, thiab qhov chaw hloov chaw kuj tseem tuaj yeem txhawb ntau hom kev ua haujlwm. Nco ntsoov xyuas daim ntawv qhia meej module datasheet thiab host chaw nres nkoj configuration.
QSFP-DD vs OSFP Loj, Chaw nres nkoj ceev thiab Thermal Design

Kev tshawb nrhiav "QSFP-DD vs OSFP loj" feem ntau ua rau cov lus xaus dhau los. OSFP siv lub hnab ntawv kho tshuab loj dua li QSFP tsev neeg, thaum QSFP-DD khaws QSFP-tsev neeg dav thiab qhov siab thiab txuas ntxiv tus tswv tsev sib sib zog nqus kom haum rau kev sib cuag ntxiv. Qhov sib txawv ntawm qhov sib txawv tuaj yeem cuam tshuam rau kev tsim heatsink, airflow thiab pem hauv ntej - vaj huam sib luag engineering, tab sis nws tsis tsim ib qho chaw nres nkoj thoob ntiaj teb - ceev ceev.
QSFP tam sim no-DD specification hais tias mus txog 36 QSFP-DD- tsev neeg modules tuaj yeem nyob hauv 1U 19-nti khib thaum lub kaw lus muab qhov xav tau cua txias thiab cua ntws. OSFP MSA kuj tseem hais tias txog li 36 OSFP chaw nres nkoj tuaj yeem txhawb nqa ntawm 1U pem hauv ntej vaj huam sib luag.
Qhov ntawd ua rau qhov luv luv ntawm "QSFP-DD sib npaug 36 chaw nres nkoj thiab OSFP sib npaug 32 chaw nres nkoj" tsis ntseeg. Qhov ceev tiag tiag yog cov cuab yeej ntawm qhov hloov SKU, tsis yog lub pob transceiver nkaus xwb.
Thaum sib piv ob lub platform, tshuaj xyuas:
- pem hauv ntej - vaj huam sib luag chaw nres nkoj suav
- aggregate switching muaj peev xwm
- txhawb chaw nres nkoj thiab breakout hom
- airflow kev taw qhia thiab heatsink tsim
- module fais fab lub hnab ntawv
- fais fab - muaj peev xwm muab khoom
- oversubscription thiab ntaub architecture
QSFP-DD vs OSFP Kev siv hluav taws xob: Vim li cas Tsis Muaj Tus lej
Tsis muaj cov lus qhia zoo thoob ntiaj teb hais tias "OSFP siv zog ntau dua" lossis "QSFP-DD ib txwm ua kom txias dua." Kev siv hluav taws xob yog nyob ntawm qhov tshwj xeeb transceiver lossis cable tsim, thaum lub peev xwm thermal belongs rau kev ua tiav tswv tsev.
Ib qho luv luv -mus txog multimode module, ib qho tib qho tib yam -mode module, WDM module, coherent optic thiab ib qho khoom siv hluav taws xob tuaj yeem muaj qhov sib txawv hauv DSP, laser thiab thermal xav tau txawm tias lawv sib koom tib daim ntawv.
Rau kev yuav khoom, sib piv qhov tseeb module qhov siab tshaj plaws lub zog tshwj xeeb tiv thaiv tus tswv tsev lub hnab ntawv thermal. Nug tus neeg muag khoom lossis tus neeg muag khoom hloov pauv rau cov chav kawm fais fab uas pom zoo, qhov kev xav ntawm airflow, kev ua haujlwm kub thiab txhua yam kev txwv uas siv thaum tag nrho pem hauv ntej - vaj huam sib luag chaw nres nkoj.
QSFP tam sim no-DD hardware specification suav nrog cov kev cai thermal kom pom tseeb rau qhov ntom ntom 1U kev xa tawm, thaum OSFP specifications txhais kev sib xyaw ua ke -heatsink thiab caij-heatsink architectures. Cov kev qhia tshwj xeeb no tsim cov txheej txheem tsim kho tshuab thiab thermal; lawv tsis hloov qhov xav tau kom tsim nyog rau qhov tseeb optic hauv qhov hloov pauv tiag tiag.
QSFP-DD vs OSFP Tus Nqi: Sib piv TCO, Tsis yog Module Nqe xwb
QSFP muaj txiaj ntsig-DD vs OSFP tus nqi sib piv tsis tuaj yeem txo qis rau tus nqi transceiver vim tias tus nqi tseem ceeb tuaj yeem los ntawm qhov chaw nyob ib puag ncig.
Siv tag nrho - tus qauv nqi xws li:
TCO=hloov platform + optics + reusable optics + adapters + cabling hloov + lub zog thiab txias + kev ua haujlwm tsiv teb tsaws + kev tsim nyog siv zog + kev pheej hmoo ua haujlwm
Rau QSFP28 network uas twb muaj lawm, QSFP-DD tuaj yeem muaj qhov zoo ntawm kev tsiv teb tsaws chaw thaum tus tswv tsev tshiab txhawb nqa QSFP qub- cov tsev neeg cov qauv thiab cov khoom muaj fiber ntau tuaj yeem nyob hauv kev pabcuam. Hauv kev xa mus rau thaj chaw ntsuab, qhov khoom qub txeeg qub teg yuav tsawg dua, yog li kev hloov kho vaj tse, kho qhov muag pom, tsim thermal thiab ntev - lub sij hawm platform roadmap tuaj yeem nqa hnyav dua.
Txhawm rau kom tau txais cov lus sib piv, khaws qhov kev thov kom ncav cuag, kho qhov muag PMD, qib kub, txuas, lav, tus neeg muag khoom coding, FEC cov cai thiab kev txhawb nqa qib tib yam. Txwv tsis pub tus nqi qis dua tuaj yeem tsuas yog sawv cev rau qhov sib txawv ntawm kev ua haujlwm.
QSFP-DD vs OSFP rau 400G Networks
Ntawm 400G, ob qho tib si QSFP-DD thiab OSFP tuaj yeem yog tus tswv tsev siv tau- sab xaiv. Pib nrog lub platform hloov, tom qab ntawd tsim nyog rau optics.
Yog tias lub network twb muaj lub hauv paus loj QSFP28 ntsia, QSFP-DD platform yuav ua kom yooj yim rau kev tsiv teb tsaws chaw vim tias QSFP-DD tsev neeg kho vajtse tau tsim los ntawm QSFP rov qab sib raug zoo. Qhov ntawd tsis tau txhais hais tias txhua 100G optic qub tuaj yeem rov siv dua. Txhua qhov hloov pauv tseem xav tau los txhawb qhov cuam tshuam qis dua - hom nrawm thiab module.
Ntawm sab fiber ntau, xyuas seb tus tshiab 400G PMD hloov cov kab txuas txuas. Tsiv ntawm duplex WDM thiab parallel optics tuaj yeem hloov pauv qhov sib txuas, suav fiber ntau thiab polarity xav tau txawm tias qhov hloov pauv hloov pauv nws tus kheej zoo li yooj yim.
Rau kev sib piv -optics designs, ib qho kev ua raws li-up yog qhovMPO breakout cable xaiv phau ntawv qhia. Rau duplex optical links, connector kev ua tau zoo thiab poob nyiaj txiag yog them rau hauvLC fiber ntau connector qhia.
QSFP-DD vs OSFP rau 800G thiab AI Clusters
Rau cov tshiab 800G AI, HPC lossis scale- tawm cov ntaub ntawv chaw network, tsis yog QSFP-DD800 lossis OSFP800 yuav tsum tau xaiv ntawm nws tus kheej los ntawm tus tswv tsev platform. Qhov hloov, accelerator, NIC lossis ntaub architecture feem ntau txiav txim siab seb daim ntawv twg muaj nyob rau txhua sab.
Qhov no yog qhov tseem ceeb tshwj xeeb vim tias qhov siab -bandwidth txuas tuaj yeem siv cov pob khoom sib txawv ntawm ob qhov kawg. Ib lub cuab yeej siv tau OSFP thaum lwm tus siv QSFP-tsev neeg chaw nres nkoj, muab cov fiber ntau- sab optical interfaces sib xws thiab ob qho tib si hauv zos txhawb nqa lawv cov transceivers.
Thaum ntsuas 800G platforms, sib piv:
- hloov thiab NIC chaw nres nkoj architecture
- pom zoo transceiver thiab cable daim ntawv teev npe
- ncaj- dhau ntawm kev ua haujlwm sib cais
- module lub zog siab tshaj plaws
- airflow thiab thermal headroom ntawm tag nrho cov chaw nres nkoj pej xeem
- fiber ncav cuag thiab connector hom
- DOM thiab kev txhawb nqa kev tswj hwm
- firmware thiab software tsim nyog
Cov ntaub ntawv NVIDIA tam sim no qhia txog vim li cas tus tswv tsev tsim ua ntej: txawv NVIDIA hloov, adapter thiab accelerator platforms siv OSFP thiab QSFP sib txawv-tsev neeg siv thiab tsim cov cai tshwj xeeb. Cov lus qhia tswv yim tsis yog los nthuav qhia ib tus neeg muag khoom tsim rau tag nrho lub khw, tab sis kho cov ntaub ntawv xaiv platform raws li qhov tseeb.
QSFP-DD vs OSFP rau 1.6T Kev Npaj
Ob qhov loj yim - txoj kab kev - cov tsev neeg tam sim no muaj 1.6T- cov khoom siv kho vajtse taw qhia.
QSFP-DD Rev 7.1 txhais QSFP-DD1600 nrog yim 200G-chav kawm txoj kab hluav taws xob. Cov kev qhia ntawm OSFP tam sim no zoo ib yam nrog OSFP1600 thiab OSFP1600-RHS variants nrog 200G- ib txoj kab hluav taws xob ua haujlwm.
Qhov no tsis txhais hais tias txhua 1.6T optical PMD, ncav cuag lossis hloov lub platform yog universally muaj nyob rau hauv ob lub pob. Daim ntawv-factor readiness tsuas yog ib feem ntawm 1.6T roadmap. Pawg neeg yuav khoom yuav tsum cais plaub nqe lus nug:
- Puas yog tus tswv tsev hluav taws xob interface tau npaj rau tiam yuav tsum tau muaj?
- Puas yog tus neeg muag khoom hloov pauv txhawb hom module xav tau?
- Puas yog qhov tsim nyog kho qhov muag PMD muaj thiab tsim nyog?
- Cov nroj tsuag fiber ntau uas twb muaj lawm tuaj yeem txhawb nqa qhov txuas, suav fiber ntau thiab ncav cuag?
Yuav hloov kho li cas los ntawm QSFP28 100G rau 400G
Ib qho 100G-rau-400G tsiv teb tsaws yuav tsum tau npaj ua qhov txuas thiab hloov kho lub platform, tsis yog kev sib pauv hloov pauv yooj yim.

Kauj Ruam 1: Tshawb xyuas cov chaw nres nkoj uas twb muaj lawm, Optics thiab Cable
Sau cov qauv hloov, kev khiav hauj lwm systems, chaw nres nkoj speeds, QSFP28 optic hom, DACs, AOCs, txuas kev ncua deb, fiber ntau hom, connector hom, thaj panels, breakout cables thiab cov khoom seem. Qhov no txheeb xyuas cov khoom muaj nqis twg muaj lub caij nyoog tiag tiag ntawm kev khaws cia.
Kauj Ruam 2: Txiav txim siab qhov txuas twg xav tau 400G
Kev loj hlob bandwidth tsis tshua muaj sib xws. Muab qhov tseem ceeb ntawm kev sib txuas ntawm tus txha nraub qaum, txoj hauv kev sib sau ua ke, cov ntaub ntim khoom, sab hnub tuaj - sab hnub poob txoj hauv kev tsheb thiab GPU lossis cov kab nrawm nrawm qhov twg 100G tau dhau los ua lub hauv paus caj dab.
Kauj ruam 3: Xaiv Lub Hom Phiaj Hloov Architecture
Xaiv qhov hloov ua ntej xauv rau hauv tus tswv tsev - sab qhov muag daim ntawv foos. Yog tias lub platform siv QSFP-DD, xyuas seb 100G QSFP hom twg tau txais kev txhawb nqa. Yog tias nws siv OSFP, paub meej tias qhov yuav tsum tau muaj OSFP variant thiab seb puas muaj qis dua - nrawm lossis adapter- raws li cov qauv tsim nyog.
Kauj Ruam 4: Sib phim Optical PMD rau Fiber Plant
Kos ncav cuag, suav txoj kab hluav taws xob, lub voj voog lub voj voog, qhov sib txuas, polarity thiab poob peev nyiaj. Ib qho uas twb muaj lawm duplex ib leeg-hom nroj tsuag tuaj yeem txhawb nqa qee qhov 400G WDM architectures nrog kev hloov pauv hloov pauv, thaum qhov sib txuas optics tuaj yeem xav tau MPO / MTP qauv sib txawv.
Yog tias kev tsiv teb tsaws muaj ib qho -mode infrastructure, lubib leeg- hom fiber ntau hom thiab daim ntawv thov kev qhiamuab cov keeb kwm yav dhau ntxiv rau kev ntsuam xyuas cov nroj tsuag fiber ntau.
Kauj ruam 5: Validate FEC, Breakout thiab Firmware
Paub meej tias yuav tsum tau FEC hom, chaw nres nkoj ceev, breakout chaw, module firmware, hloov software, DOM kev them nyiaj yug thiab vendor coding. Cov tswv tsev no- cov kev cai sab nraud yog cov peev txheej ntawm kev xa mus tsis tau txawm tias thaum cov khoom siv tshuab thiab cov khoom siv fiber ntau yog lawm.
Kauj Ruam 6: Pilot Representative Links
Ua ntej ib qho kev nthuav tawm loj, sim cov neeg sawv cev sib txuas nyob rau hauv tib lub kho vajtse, firmware thiab cabling tej yam kev mob xav tau nyob rau hauv ntau lawm. Txhim kho qhov txuas txuas, ua ntej-FEC thiab tshaj tawm-FEC tus cwj pwm yuam kev thaum muaj, tswb, DOM telemetry, kub, reboot rov qab thiab sib xyaw- neeg muag khoom sib cuam tshuam.
Yog tias koj pab neeg tseem tab tom tshuaj xyuas cov lus siv kho qhov muag thaum lub sijhawm tsiv teb tsaws, qhovtransceiver vs transponder sib pivtuaj yeem pab cais cov neeg siv khoom siv kho qhov muag los ntawm kev thauj - network functions.
Koj yuav tsum xaiv qhov Form Factor twg? Kev txiav txim siab ntawm buyer Matrix
| Deployment Scenario | Pom zoo pib Point | Vim li cas | Dab tsi los txheeb xyuas ua ntej yuav khoom |
|---|---|---|---|
| Lub network uas twb muaj lawm tseem nyob ntawm 100G | QSFP28 | Mature ntsia ecosystem thiab tsis tas yuav them rau qhov siab dua -kev hloov pauv ceev | Optical ncav cuag, fiber ntau cog, hloov muaj thiab cov neeg muag khoom txhawb nqa |
| QSFP28 network uas twb muaj lawm tsiv xaiv cov txuas mus rau 400G | Ntsuas QSFP-DD platforms ua ntej | QSFP-tsev neeg rov qab- sib haum xeeb architecture tuaj yeem pab cuam tshuam kev tsiv teb tsaws | Tsawg dua - hom chaw nres nkoj ceev, kev them nyiaj yug module tiag tiag, FEC, fiber ntau rov siv dua thiab hloov pauv cable |
| Tshiab 400G network | Platform nyob ntawm | QSFP-DD thiab OSFP tuaj yeem txhawb nqa 400G-chav xa tawm | Hloov tus nqi, optics muaj, thermal tsim, chaw nres nkoj ceev thiab cabling |
| Tshiab 800G AI lossis HPC pawg | Ua raws li kev xaiv hloov thiab accelerator ecosystem | Lub platform host ib txwm txiav txim siab QSFP-DD800 lossis OSFP800 muaj | Pom zoo optics, lub zog, thermal headroom, breakout hom thiab interconnect topology |
| Thermally xav tau siab - lub zog tsim | Sib piv cov tshuab ua tiav, tsis yog daim ntawv -factor labels | OSFP muab ob peb lub heatsink architectures, thaum QSFP-DD kuj suav nrog cov txheej txheem- theem thermal | Qhov tseeb module watts, airflow, tag nrho -cov pej xeem txwv thiab hloov tus neeg muag khoom tsim nyog |
| Kev npaj rau 1.6T | Ntsuas ob qho tib si QSFP-DD1600 thiab OSFP1600 txoj kev qhia | Ob tsev neeg tam sim no txhais tau 200G-ib - txoj kab yim - kab ke | Muaj qhov hloov pauv tiag tiag, PMD muaj, lub zog, cua txias, FEC thiab fiber ntau architecture |
Feem ntau yuam kev thaum piv QSFP-DD, QSFP28 thiab OSFP
yuam kev 1: Piv txwv tias daim foos Factors sib npaug ntawm Network Ceev
QSFP-DD thiab OSFP txhua qhov txuas ntau tiam neeg bandwidth. Xyuas qhov tseeb transceiver thiab host hluav taws xob hom.
Ua yuam kev 2: Piv txwv lub cev haum txhais tau tias tag nrho kev sib raug zoo
Ib qho module yuav haum rau mechanically thiab tseem ua tsis tau vim qhov hloov pauv tsis txhawb qhov nrawm, hom kab, firmware, FEC lossis module coding.
Qhov yuam kev 3: Piv txwv tias cov qauv sib txawv tsis tuaj yeem cuam tshuam kev ua haujlwm optically
Tus tswv tsev - sab pob tuaj yeem sib txawv thaum cov fiber ntau - sab PMDs tseem sib xws. Txheeb xyuas qhov optical interface ntawm nws tus kheej.
Qhov yuam kev 4: Tsis quav ntsej cov nroj tsuag Fiber
Ib qho kev txav los ntawm 100G mus rau 400G lossis 800G tuaj yeem hloov pauv fiber ntau suav, polarity, connector hom thiab thaj - vaj huam sib luag yuav tsum tau. Lub module daim ntawv foos tsis tuaj yeem lav kev rov siv dua.
Qhov yuam kev 5: Sib piv cov lej muaj zog
Sib piv qhov tseeb transceiver siab tshaj plaws hwj chim nrog tus tswv tsev thermal txwv. Daim ntawv foos tsis yog hloov pauv rau daim ntawv teev cov ntaub ntawv module.
Qhov yuam kev 6: Siv qhov chaw ruaj khov-Txoj Cai Ceev
Ob QSFP-DD thiab OSFP specifications txhawb siab -cov tshuab ceev. Sib piv qhov tseeb hloov SKU es tsis txhob cia siab rau ib nqe lus 36-vsus-32.
Yuam kev 7: Xaiv lub Transceiver ua ntej hloov
Rau ntau qhov haujlwm 400G thiab 800G, qhov no thim rov qab qhov kev txiav txim kom raug. Xaiv lub network architecture thiab hloov platform ua ntej, tom qab ntawd tsim nyog cov optics uas tus tswv txhawb nqa.
FAQ
Puas yog QSFP-DD zoo ib yam li QSFP28?
QSFP-DD khaws cia QSFP-tsev neeg dav thiab qhov siab thaum txuas tus tswv tsev sib sib zog nqus kom haum rau cov xov tooj hluav taws xob ntxiv uas xav tau rau yim txoj kab. Qhov kev tsim no yog lub hauv paus rau nws QSFP-tsev neeg rov qab- tau tshaj architecture.
Kuv puas tuaj yeem siv QSFP28 module hauv QSFP-DD hloov?
Muaj peev xwm, yog. QSFP-DD hardware yog tsim los lees txais QSFP ua ntej-tsev neeg modules, tab sis qhov hloov yuav tsum txhawb nqa qhov thov 100G hom thiab cov qauv tshwj xeeb. Txheeb xyuas cov ntawv qhia kho vajtse, software tso tawm thiab pom zoo cov npe optics ua ntej xa mus.
Kuv puas tuaj yeem ntsaws QSFP-DD transceiver rau hauv QSFP28 chaw nres nkoj?
Tsis yog. Ib tus tswv tsev QSFP28 ib txwm tsis muab QSFP txuas ntxiv -DD hluav taws xob thiab cov khoom siv sib txuas.
Puas yog OSFP sai dua QSFP-DD?
Tsis yog. Form factor ib leeg tsis txiav txim siab ceev. Ob QSFP-DD thiab OSFP tsev neeg suav nrog 400G, 800G thiab 1.6T- tiam neeg.
Qhov twg zoo dua rau 800G, QSFP-DD lossis OSFP?
Tsis muaj universal yeej. Qhov kev xaiv zoo dua yog daim ntawv thov kev txhawb nqa los ntawm lub hom phiaj hloov, NIC lossis accelerator platform nrog qhov xav tau optics, cabling thiab thermal headroom. Sib piv cov txheej txheem tiav es tsis yog pob hauv kev sib cais.
Qhov twg muaj kev siv hluav taws xob qis dua, QSFP-DD lossis OSFP?
Tsis muaj peev xwm tshaj tawm universally qis zog. Kev siv tiag tiag nyob ntawm tus qauv transceiver, optical ncav cuag, DSP, laser architecture thiab kev ua haujlwm hom. Sib piv cov module- theem zog specifications thiab host thermal txwv.
Puas yog OSFP txhawb nqa 1.6T?
Yog lawm. OSFP specification tam sim no suav nrog OSFP1600 thiab OSFP1600-RHS variants nrog yim 200G-chav hluav taws xob kab.
Puas yog QSFP-DD txhawb 1.6T?
Yog lawm. QSFP-DD Rev 7.1 suav nrog QSFP-DD1600 nrog yim 200G-chav kawm kab hluav taws xob rau 1.6T-chav ua haujlwm sib sau ua ke.
OSFP transceiver puas tuaj yeem txuas mus rau QSFP-DD transceiver?
Cov modules tsis tuaj yeem muab tso rau hauv ib leeg lub party tawb. Ib qhov txuas fiber ntau tseem tuaj yeem siv OSFP ntawm ib qho kawg thiab QSFP-DD ntawm lwm qhov thaum cov transceivers siv cov khoom siv kho qhov muag sib xws thiab txhua qhov hloov hauv zos txhawb nqa nws tus kheej module.
OSFP chaw nres nkoj puas tuaj yeem siv QSFP adapter?
Qee qhov adapter-raws li kev daws teeb meem muaj nyob, thiab OSFP MSA cov nplooj ntawv sau npe thib peb -party OSFP- rau -QSFP piv txwv. Qhov ntawd tsis zoo ib yam li kev txhawb nqa thoob ntiaj teb. Txheeb xyuas qhov tshwj xeeb hloov, adapter, module, chaw nres nkoj hom thiab thermal yuav tsum ua ntej siv lub adapter hauv kev tsim khoom.
Kev Pom Zoo Kawg
QSFP-DD vs QSFP28 vs OSFP kev txiav txim siab yuav tsum pib nrog lub network architecture, tsis yog nrog daim ntawv lo transceiver.
- Khaws QSFP28thaum 100G txuas ntxiv ua kom tau raws li qhov yuav tsum tau muaj bandwidth thiab tsis muaj laj thawj kev ua haujlwm meej rau kev tsiv teb tsaws.
- Ntsuas QSFP-DDthaum tsiv ib qho QSFP ecosystem uas twb muaj lawm mus rau 400G, 800G los yog 1.6T-chav kawm platforms thiab rov qab- sib haum mus txawv tebchaws yooj muaj nqi tiag tiag.
- Xaiv OSFPthaum xaiv high -bandwidth hloov, accelerator ntaub los yog system architecture yog tsim nyob ib ncig ntawm OSFP ecosystem.
- Rau 400G thiab 800G Greenfield xa tawm, xaiv qhov hloov pauv thiab network topology ua ntej, tom qab ntawd tsim nyog cov kev txhawb nqa optics.
- Rau 1.6T kev npaj, kho daim ntawv-factor readiness, switch available, optical PMD available, power and fiber architecture as cais kev txiav txim.