Kev xaiv ntawm MPO-8, MPO-12, thiab MPO-24 tsis yog qhov teeb meem ntawm kev sib piv cov fiber ntau suav rau Ethernet ceev. Cov cuab yeej-ntsib kev sib txuas yuav tsum ua kom haum rau qhov sib txuas ntawm qhov muag ntawm lub transceiver, thaum lub nraub qaum tuaj yeem siv qhov sib txawv cabling architecture yog tias daim ntawv qhia fiber ntau, polarity, connector hom, thiab cov peev nyiaj poob tau raug kho kom raug.
Qhov kev sib txawv ntawd kuj piav qhia vim li casMPO-16koom nrog hauv qhov kev sib tham no yam tsis tau hloov mus ua plaub - txoj kev sib piv. MPO-16 yog qhov tshwj xeeb tseem ceeb rau qee qhov niaj hnub yim-txoj kab kev kho qhov muag, tshwj xeeb tshaj yog ntawm 400G thiab 800G, tab sis nws tsis ua rau Base-8, Base-12, lossis MPO-24 siv tsis tau.

MPO-8 vs MPO-12 vs MPO-24
| MPO configuration | Fiber suav | Zoo tshaj plaws | Lub ntsiab kom zoo dua | Kev txwv loj |
|---|---|---|---|---|
| MPO-8 / Base-8 | 8 | Plaub -kab kab uas hla optics thiab breakout architectures | Siv tag nrho yim fibers hauv daim ntawv thov 8-fiber | Tsis tuaj yeem ua haujlwm ncaj qha rau 16-active-fiber interface |
| MPO-12 / Base-12 | 12 | Cov txheej txheem cabling uas twb muaj lawm, duplex aggregation, thiab ntau MPO-raws li txuas | Yooj yim nruab -base architecture | Plaub txoj haujlwm yuav tsis siv rau hauv daim ntawv thov 8-fiber |
| MPO-24 | 24 | Siab -cov pob tw thiab sib sau ua ke | Consolidates ntau fibers rau hauv tsawg dua siab - suav kev sib txuas | Ntxiv peev xwm tsis ua rau nws ib tug universal ntaus ntawv interface |
| MPO-16 | 16 | Tseem ceeb tshwj xeeb: qee yim -pair parallel optical interfaces | Ncaj nraim matches 8 Tx + 8 Rx designs thaum teev | Yuav tsum phim qhov tseeb transceiver connector, polish, thiab daim ntawv qhia |
Lub rooj yog cov cuab yeej siv kab txuas, tsis yog daim ntawv qhia ceev. Ib kab ib tus nqi tuaj yeem xa los ntawm optics nrog cov xov xwm sib txawv thiab cov khoom sib txuas.
Pib nrog Optical Module, Tsis yog Chaw nres nkoj ceev
Xav txog plaub 400G modules los ntawm Cisco's400G QSFP-DD transceiver data sheet:
- QDD-400G-SR8-S:yim khub ntawm multimode fiber ntau nrog MPO-16 APC interface.
- QDD-400G-SR4.2-BD:plaub khub ntawm multimode fiber ntau nrog MPO-12 UPC interface.
- QDD-400G-DR4-S:plaub khub ntawm ib qho - hom fiber ntau los ntawm MPO-12 interface; Cisco teev MPO-12 APC hauv nws cov kev qhia kho qhov muag.
- QDD-400G-FR4-S:duplex ib leeg - hom fiber ntau nrog LC interface es tsis yog MPO.
Tag nrho plaub yog 400G optics, tab sis lawv cov kev sib txuas ntawm lub cev tsis hloov pauv. Qhov no yog vim li cas qhov kev thov yuav khoom xws li "400G MPO cable" tsis tiav. Sau tus neeg muag khoom, ib feem naj npawb, xov xwm, connector, polish, thiab fiber ntau daim ntawv qhia ua ntej xaiv cov cable sib dhos.
Yog tias daim ntawv foos nws tus kheej yog ib feem ntawm cov lus nug tsim, qhov noQSFP-DD technical overviewmuab cov ntsiab lus ntxiv.

Ob Qhov Kev Sib Tw Uas Tiv Thaiv Feem Ntau Fiber- suav yuam kev
Connector txoj hauj lwm thiab Active Fibers yog txawv
Ib lub connector tuaj yeem muaj ntau txoj haujlwm fiber ntau dua li qhov kev siv kho qhov muag nquag siv. Classic 40GBASE-SR4 thiab 100GBASE-SR4 txuas siv plaub xaim fibers thiab plaub tau txais fibers. Hauv kev xa tawm thaum ntxov, cov yim fibers nquag tau nqa los ntawm 12-txoj haujlwm MPO kev sib txuas, ua rau plaub qhov chaw ua haujlwm tsis ua haujlwm.Fluke Networks '12-fiber thiab 8-fiber MPO kev taw qhiacov ntaub ntawv no daim ntawv qhia thiab kev txhim kho ntawm Base-8 txuas.
Qhov no yog lub hauv paus ntawm ib qho kev tsim yuam kev: "MPO-12" piav qhia txog cov khoom sib txuas lossis cabling lub tsev thaiv, tab sis nws tsis tau txhais hais tias tag nrho 12 fibers nqa tsheb. Daim ntawv thov fiber ntau daim ntawv qhia yog dab tsi qhia koj cov haujlwm twg ua haujlwm.
Base-8 thiab Base-12 Piav txog Cabling Architecture
Base -8 thiab Base-12 yog qhov muaj txiaj ntsig zoo dua thaum kho raws li cov txheej txheem-cabling lub tsev thaiv es tsis yog cov ntawv lo rau ib qho kev sib txuas. A Base-8 tsim pab pawg muaj peev xwm hauv ntau ntawm yim; Base-12 tsim pab pawg muaj peev xwm hauv ntau ntawm kaum ob. Ib qho kev tsim qauv tuaj yeem txhawb nqa ntau dua ib daim ntawv thov thaum cov khoom hloov pauv tau tsim kom raug.
Qhov no kuj txhais tau hais tias lub connector tig rau lub transceiver tsis tas yuav dictate cov fiber ntau siv nyob txhua qhov chaw hauv cov ntaub ntawv chaw. Cov pob txha caj qaum, cov ntaub ntawv, cov hlua, thiab cov khoom siv hlua ua ib qho kawg - mus rau - kawg channel. Lawv txoj hauj lwm yog xa cov fibers uas yuav tsum tau mus rau txoj haujlwm raug nyob rau hauv cov nyiaj tso cai poob.
Yuav ua li cas MPO-8, MPO-12, thiab MPO-24 haum txawv Architecture
Thaum MPO-8 / Base-8 Ua rau Sense
Lub hauv paus-8 yog qhov haum rau ntuj thaum thaj chaw greenfield yog thawj ntawm plaub- txoj kab sib luag optics uas siv plaub kis thiab plaub tau txais fibers. Rau cov kev sib txuas, ib qho yim-fiber tsev thaiv tsis txhob nqa plaub txoj haujlwm tsis muaj zog hauv txhua pawg 12-fiber.
Nws yog ib qho tseem ceeb tshwj xeeb tshaj yog nyob rau hauv breakout- hnyav designs. Ib qho plaub - txoj kab kev sib txuas tuaj yeem tsim tau rau plaub qhov kev sib txuas duplex yam tsis tau pib dua ib pawg 12-fiber. Yog hais tias breakout yog central rau koj topology, lubMPO breakout cable qhiapiav qhia txog qhov sib txawv ntawm qhov sib txawv ntawm kev sib cais.
Base-8 tsis tshua muaj siab thaum xaiv optic xav tau 16 active fibers. Ib yim-fiber cable tsis tuaj yeem muab yim xa mus ncaj qha thiab yim tau txais txoj haujlwm. Thaum lub sij hawm ntawd tus tsim yuav xav tau MPO-16, ntau MPO connectors, los yog ib tug sib txawv optical interface tag nrho.
Thaum khaws MPO-12 / Base-12 yog qhov kev txiav txim siab zoo dua
Base-12 tseem muaj txiaj ntsig vim tias kev txiav txim siab ntawm cov cabling txheej txheem tsis yog ua los ntawm kev siv fiber ntau ib leeg. Ib qho chaw tsim khoom Base-12 tej zaum yuav muaj cov pob tw tsim nyog, panels, cassettes, cov khoom seem, cov ntaub ntawv xeem, thiab cov txheej txheem ua haujlwm. Hloov tag nrho cov ntawd kom tshem tawm ob peb txoj haujlwm tsis ua haujlwm tuaj yeem raug nqi ntau dua thiab tsim kev pheej hmoo ntau dua li nws tshem tawm.
Txoj kev 12-txoj haujlwm MPO tuaj yeem nqa tau 8-fiber SR4 daim ntawv thov nrog plaub txoj haujlwm tsis siv. Kev hloov dua siab tshiab yuav cuam tshuam thaum lub hom phiaj yog los txhim kho lub peev xwm ua tau zoo dua. Ob pawg 12-fiber muaj 24 fibers nyob rau hauv tag nrho, uas tuaj yeem rov ua dua rau hauv peb 8-fiber pawg thaum lub kaw lus cabling yog tsim los rau qhov hloov dua siab tshiab.
Rau kev npaj brownfield, tshuaj xyuas qhov uas twb muaj lawmMPO / MTP lub cev cable architectureua ntej txiav txim siab seb qhov kev tsiv teb tsaws yuav tsum muaj cov pob tw tshiab lossis tsuas yog hloov pauv ntawm cov khoom faib thiab cov txheej txheem.
Qhov twg MPO-24 haum zoo tshaj plaws
MPO-24 yog qhov tseem ceeb tshaj plaws raws li cov cuab yeej sib sau ua ke. Nees nkaum-plaub fibers tuaj yeem nqa tau los ntawm ib qho kev sib txuas ntawm ib qho kev suav siab thiab tom qab ntawd muab faib rau hauv cov pab pawg me dua qhov twg cov architecture xav tau. Ua lej, 24 fibers faib huv si rau hauv ob pawg 12-fiber lossis peb 8-fiber pawg.
Qhov ntawd tsis txhais hais tias MPO-24 lub cev yuav tsum tau txuas ncaj qha rau txhua qhov siab -ceev transceiver. Device-facing compatibility tseem nyob ntawm qhov tseeb optical interface. Hauv kev xyaum, MPO-24 feem ntau yog qhov tseem ceeb tshaj plaws nyob rau hauv lub nraub qaum lossis cov txheej txheem sib sau ua ke, thaum cov khoom siv los yog cov khoom siv nthuav tawm cov khoom sib txuas uas xav tau los ntawm cov khoom siv.
Yog tias koj txiav txim siab ntawm lub cev ncaj thiab tus kiv cua- tawm los ua ke, phau ntawv qhia no rauMPO pob tw thiab breakout cable homyog ib kauj ruam tom ntej pab tau.

Qhov kev zam MPO-16: Thaum 16 Active Fibers yog qhov xav tau tiag tiag
MPO-16 tseem ceeb thaum lub transceiver nthuav tawm yim kis fibers thiab yim tau txais fibers los ntawm ib qho 16-fiber interface. Ib txwm MPO-16 connectors tso 16 fibers nyob rau hauv ib kab, thiab lub connector yog lub cev txawv ntawm cov paub 8- thiab 12-fiber kev npaj.
Cisco QDD-400G-SR8-S yog qhov tseeb 400G piv txwv: nws siv yim khub ntawm ntau hom fiber ntau thiab MPO-16 APC txuas. Ntawm 800G, Cisco'sOSFP 800G transceiver data sheetqhia ob txoj hauv kev. OSFP-800G-VR8 thiab OSFP-800G-DR8 siv dual MPO-12 APC interfaces, thaum sib xws VR8P thiab DR8P versions siv ib qho MPO-16 APC interface.
Zaj lus qhia yog nqaim dua "800G xav tau MPO-16." Nws yog tias ob lub optics ua haujlwm tib yam kev ceev thiab txoj kab hauv tsev tuaj yeem nthuav tawm cov khoom sib txawv ntawm lub cev. Tus lej feem tseem yog qhov kawg siv.
Ib qho piv txwv ua haujlwm Brownfield: Base-12 Backbone, Tshiab 400G SR8 Optics
Xav txog ib lub chaw khaws ntaub ntawv nrog lub hauv paus uas twb muaj lawm -12 qaum qaum uas tseem nyob hauv nws qhov kho qhov muag - nyiaj txiag poob. Cov nplooj hloov tshiab tau nruab nrog Cisco QDD-400G-SR8-S modules. Sab transceiver tam sim no xav tau MPO-16 APC, tab sis qhov yuav tsum tau ua tsis tau tso cai hloov txhua lub pob Base-12 hauv qhov chaw.
Kev txiav txim siab engineering yog ua nyob rau theem channel. Ib qho kev xaiv yog xa tawm 16- fiber ntau txoj hauv kev rau cov kev cuam tshuam. Lwm qhov yog khaws cia tsim nyog Base-12 infrastructure qhov twg nws tseem muab lub peev xwm siv tau thiab qhia txog kev txhawb nqa kev hloov pauv ntawm ntug. Ob txoj hauv kev yuav tsum xa tag nrho 16 qhov xav tau fibers mus rau qhov tseeb MPO-16 txoj haujlwm thaum tswj cov polarity, connector poj niam txiv neej, polish, thiab insertion-poob txwv.
Dab tsi yuav tsis ua haujlwm yog kho MPO-12 thiab MPO-16 raws li kev hloov pauv tau tsuas yog vim ob leeg yog MPO-tsev neeg txuas. Cov khoom siv-ntsej muag interface yuav tsum tau nthuav tawm raws nraim li lub transceiver xav tau.
Kev txiav txim ceev
- Koj lub optic siv 8-fiber parallel interface:Base-8 yog qhov ua tau zoo, tab sis ib qho uas twb muaj lawm Base-12 channel tseem tuaj yeem siv tau yog tias daim ntawv qhia fiber ntau thiab cov khoom sib txuas sib tw.
- Koj lub optic qhia txog MPO-12:siv qhov xav tau MPO-12 interface txawm tias tsuas yog yim txoj haujlwm tseem ua haujlwm.
- Koj lub optic qhia txog MPO-16:muab qhov xav tau 16-fiber ntaus ntawv-fab interface; Tsis txhob hloov MPO-8, MPO-12, lossis MPO-24 los ntawm fiber ntau suav lej ib leeg.
- Koj qhov teeb meem tseem ceeb yog pob txha pob txha:MPO-24 tuaj yeem pab tau raws li kev sib sau ua ke hauv tsev, nrog rau cov khoom siv sab nraud tawg lossis hloov pauv raws li qhov xav tau.
- Koj twb muaj ib tsob nroj loj Base-12:Sib piv cov nqi tsiv teb tsaws chaw, nyiaj txiag poob, lub tswv yim seem, thiab kev hloov pauv hloov ua ntej hloov cov pob tw.
- Koj tab tom tsim qhov chaw greenfield dominated los ntawm 8-fiber daim ntaub ntawv:Base-8 tuaj yeem ua kom yooj yim rau kev teeb tsa chaw nres nkoj thiab txo qis cov haujlwm fiber ntau.
-

Tsib -Txoj Kev Xaiv MPO Ua Haujlwm
- Txheeb xyuas qhov tseeb transceiver.Sau tus neeg muag khoom, ib feem naj npawb, optical standard, breakout hom, media, thiab ncav cuag. Ib qhov chaw hloov pauv tuaj yeem txhawb nqa ntau qhov optics nrog lub cev sib txawv.
- Paub meej hom fiber ntau thiab qhov deb.Cais cov fiber ntau - suav kev txiav txim siab los ntawm kev txiav txim siab tshaj tawm. Ib tug multimode SR-chav kawm txuas thiab ib zaug xwb-mode DR-chav kawm txuas tej zaum yuav muaj cov kab zoo sib xws tab sis yuav tsum tau sib txawv fiber ntau thiab connector specifications. Rau kev npaj multimode, saib covOM1-OM5 multimode fiber ntau nrug qhia.
- Daim ntawv qhia cov active fibers.Cov ntaub ntawv twg xa mus, uas tau txais, thiab uas txhob txwm tsis siv. Tsis txhob suav cov kab ntawv qhia kab los ntawm tus lej luam tawm ntawm qhov txuas.
- Match connector cov ntsiab lus.Txheeb xyuas pinned lossis unpinned mating, txoj kev polarity, kev taw qhia tseem ceeb, thiab APC lossis UPC polish.Fluke Networks 'MPO polarity referenceqhia tau hais tias hom A, B, thiab C cabling cuam tshuam li cas rau qhov kawg - mus rau - xaus fiber ntau txoj haujlwm thiab sau tseg tias cov khoom siv MPO cuam tshuam feem ntau yog pinned, xav tau cov khoom siv tsis muaj hlua.
- Ntsuas qhov ua tiav channel.Xws li cov pob tw, cassettes, adapters, harnesses, tus naj npawb ntawm kev sib txuas sib txuas, lub tswv yim seem, qhov chaw ntawm txoj kev, txoj kev sim, thiab txoj kev npaj tsiv teb tsaws chaw. Cov kab hluav taws xob uas muaj cov fibers tsawg tshaj plaws tsis tas yuav yog lub kaw lus nrog tus nqi qis tshaj plaws ntawm lub neej.
Qhov twg MPO Designs Feem ntau mus yuam kev
Siv cov kab nqi raws li cov kev qhia tshwj xeeb."400G" lossis "800G" tsis yog cov ntaub ntawv txaus los xaj ib lub cable. Cov piv txwv Cisco saum toj no qhia tias yog vim li cas.
Kev suav fiber ntau tab sis ploj ntawm cov ntsiab lus txuas.Ob lub rooj sib txoos tuaj yeem muaj 12 fibers thiab tseem ua tsis tau vim yog polarity, pinning, qhov tseem ceeb orientation, lossis polish.
Piv txwv tias ib daim ntawv lo polarity daws tag nrho cov channel.Polarity yog qhov kawg - mus rau - kawg khoom. Hom B tivthaiv tsis them nyiaj rau qhov tsis muaj ntaub ntawv tsim tawm channel.
Guessing APC lossis UPC los ntawm qhov ceev.Cisco's 400G portfolio suav nrog MPO-16 APC, MPO-12 APC, MPO-12 UPC, thiab LC-based interfaces. Polish ua raws li qhov kho qhov muag interface, tsis yog tus nqi xov tooj.
Optimizing fiber ntau siv ua ntej kev ruaj ntseg.Ntxiv cov ntsiab lus hloov dua siab tshiab, cov hlua tsis txawv txav, ntau hom khoom seem, thiab cov npoo poob qis tuaj yeem tshem tawm cov txiaj ntsig ntawm kev siv txhua txoj hlua. Kev ua haujlwm, kev sim, thiab kev txav mus tom ntej yuav tsum yog ib feem ntawm kev xaiv.
Kev tshuaj xyuas, kev sim, thiab cov peev nyiaj poob tseem txiav txim siab seb qhov txuas puas ua haujlwm
Kev suav cov fiber ntau yog tsis lav qhov ua haujlwm channel. MPO txuas tso ntau lub ntsej muag fiber ntau rau hauv ib qho kev sib txuas, yog li kev huv, kev sib raug zoo, polarity, thiab kev tso tawm tsis tsim nyog tau txais kev kuaj xyuas meej meej.
Fluke NetworksMPO test{0}}cov ntawv dawbdistinguishes xeem mus kom ze rau mus tas li txuas thiab raws thiab sau ntawv hais tias MPO transceivers yog pinned thaum cov khoom cords yog unpinned. Koj txoj kev lees txais yuav tsum tau siv cov kev txwv tsis pub dhau los ntawm kev tsim cabling thiab daim ntawv thov kho qhov muag es tsis yog tus lej dhau los / tsis ua haujlwm.
Rau kev piav qhia tob dua ntawm qhov sib txuas thiab channel poob li cas, saibkev poob qis hauv fiber ntau.
Cov lus nug nquag
Puas yog MPO-8 zoo dua MPO-12?
Tsis yog universally. MPO-8 muaj txiaj ntsig zoo rau cov ntawv thov uas siv yim fibers nquag, thaum MPO-12 tuaj yeem yog qhov kev xaiv zoo dua hauv kev tsim qauv Base-12 cov kab ke. Qhov zoo tshaj plaws tsim yog ib qho uas phim qhov kho qhov muag interface thiab txo qis kev ua haujlwm tsis tsim nyog.
Puas yog 100G SR4 siv 8 lossis 12 fibers?
Daim ntawv thov kho qhov muag siv yim active fibers: plaub kis thiab plaub tau txais. Nws kuj tau siv dav dav los ntawm 12-txoj haujlwm MPO kev sib txuas, nrog rau plaub qhov chaw ua haujlwm tsis ua haujlwm. Tias yog vim li cas active fiber suav thiab connector txoj hauj lwm suav yuav tsum tau sau tseg nyias.
Qhov twg MPO connector yog siv rau 400G?
Tsis muaj ib qho MPO txuas rau txhua 400G optic. Cisco piv txwv suav nrog MPO-16 APC rau QDD-400G-SR8-S, MPO-12 UPC rau QDD-400G-SR4.2-BD, thiab MPO-12 rau QDD-400G-DR4-S. Lwm 400G modules siv duplex LC hloov MPO.
Kuv puas xav tau MPO-24 rau 800G?
Tsis yog. MPO-24 tuaj yeem muaj txiaj ntsig zoo rau siab -cov txheej txheem ntom ntom, tab sis Cisco's 800G VR8 thiab DR8 cov ntaub ntawv qhia tau tias cov khoom siv-ntsej muag interfaces yuav siv tau MPO-16 APC lossis dual MPO-12 APC nyob ntawm qhov tseeb module.
Base-12 thiab MPO-16 puas tuaj yeem koom ua ke hauv tib lub chaw cov ntaub ntawv?
Yog lawm. Backbone architecture thiab khoom siv-fab hom connector tsis tas yuav zoo ib yam nyob txhua qhov chaw. Lawv tuaj yeem sib koom ua ke thaum lub channel yog txhob txwm tsim los muab cov haujlwm fiber ntau, polarity, connector mating, polish, thiab tsis ua haujlwm ntawm txhua qhov kawg.
Kev Pom Zoo Kawg
Rau qhov kev txiav txim siab MPO-8 vs MPO-12 vs MPO-24, thawj cais ob nqe lus nug:Dab tsi connector yog tus transceiver xav tau?thiabDab tsi cabling architecture ua rau kev nkag siab rau lub xaib?Thawj yog kho los ntawm optical module. Qhov thib ob yog nyob ntawm kev teeb tsa kev teeb tsa, qhov ceev, kev xav tau ntawm kev tawg, nqi tsiv teb tsaws, kev sim, thiab kev ua haujlwm.
Siv Base-8 qhov twg yim-fiber tsev blocks yooj yim rau kev tsim. Khaws Base-12 qhov twg nws tseem ua haujlwm zoo. Siv MPO-24 qhov kev sib sau ua ke siab yog qhov yuav tsum tau muaj tiag. Nqa hauv MPO-16 thaum ib qho kev kho qhov muag tshwj xeeb hu rau 16 active fibers. Thaum cov luag haujlwm no tau sib cais, qhov kev txiav txim siab fiber ntau ua tau yooj yim dua los tiv thaiv thiab nyuaj rau qhov tsis raug.