Fiber Optic Connector End-Face Inspection: Thov IEC 61300-3-35: 2022 rau Kev lees txais

Nov 03, 2026

Tso lus

Kev soj ntsuam lub ntsej muag kawg ntawm lub ntsej muag feem ntau raug txo kom ceev ceev ceev. Qhov luv luv no tsim ob qhov kev pheej hmoo sib txawv: lees txais cov khoom sib txuas vim tias nws zoo li huv si yam tsis tau kuaj xyuas cov txheej txheem xav tau, lossis tshem tawm cov khoom sib txuas vim tias qhov kev soj ntsuam tau tshaj tawm qhov pom qhov tsis xws luag yam tsis tau kuaj xyuas nws qhov kev ua haujlwm kho qhov muag.

IEC 61300-3-35: 2022 ua rau muaj qhov sib txawv tseem ceeb: kev tshuaj xyuas qhov muag thiab kev tsim kho qhov muag yog kev kuaj xyuas ntxiv, tsis yog hloov pauv rau ib leeg.Cov txheej txheem teb txhim khu kev qha yuav tsum txheeb xyuas cov kab mob uas tshem tau, tshuaj xyuas qhov chaw kawg ntawm lub ntsej muag uas siv cov qauv tsim nyog, thiab siv cov kev ntsuas qhov muag pom thaum pom qhov tshwm sim ib leeg tsis kho qhov tsim nyog.

Cov lus qhia no tsom rau ib leeg-fiber cylindrical-ferrule connectors uas nquag siv hauv LC, SC, FC, thiab ST cov rooj sib txoos. Nws piav qhia txog kev tshuaj xyuas thiab kev lees paub ua haujlwm rau cov kws tshaj lij, cov kws tshaj lij network, thiab QA pab pawg. Nws tsis hloov cov qauv ntawv tso cai, cov chaw tsim khoom txuas txuas cov lus qhia tu, lossis qhov kev lees paub qhov project.

 

 

Dab tsi IEC 61300-3-35: 2022 Kev Tshawb Fawb Tseeb

IEC 61300-3-35 yog ib qho kev kuaj pom qhov muag rau fiber ntau optic connectors thiab fiber-stub transceivers. Nws txhais cov txheej txheem tshuaj xyuas, yam tsawg kawg nkaus uas yuav tsum tau ua raws li cov khoom siv tshuaj ntsuam xyuas, thiab cov txheej txheem rau kev soj ntsuam cov khib nyiab, khawb, thiab lwm yam tsis xws luag. Tus nomIEC 61300-3-35: 2022 nplooj ntawv tshaj tawmtxheeb xyuas cov ntaub ntawv 2022 raws li tsab thib peb, hloov xyoo 2015.

Rau ib leeg-fiber connector, kev tshuaj xyuas tsis txwv rau saib ntawm qhov nruab nrab ntawm cov iav. Lub hauv paus thiab cladding cheeb tsam raug soj ntsuam rau cov khawb thiab qhov tsis xws luag, thaum lub cheeb tsam dav dua qhov twg ob lub ferrules sib ntsib yuav tsum tau kuaj xyuas kev sib kis. IEC piav qhia qhov chaw tiv tauj no rau cylindrical ferrules raws li txuas mus rau thaj tsam txog li 250 μm hauv txoj kab uas hla. Cov khib nyiab xoob sab nraud ntawm cov tub ntxhais tseem tuaj yeem txav mus rau qhov chaw kho qhov muag thaum tuav lossis mating.

Xyoo 2022 tsab hloov pauv yuav ua li cas lub ntsej muag kawg raug soj ntsuam piv nrog cov laus 2015 mus kom ze. Tshwj xeeb, tsis txhob luam ib daim ntawv qub plaub-zone pass/fail chart thiab xav tias nws yog qhov kev lees paub tam sim no. Qhov thib peb tsab tshem tawm cov qub Zone C thiab Zone D tshuaj xyuas raws li cov cheeb tsam sib cais, thaum khaws cov kev kuaj xyuas kom huv ntawm thaj chaw tiv tauj. Cov txheej txheem tam sim no rau cov tub ntxhais thiab cladding yuav tsum tau siv los siv cov khoom sib txuas thiab fiber ntau.

Tus qauv faib cov xwm txheej pom xws li cov khoom, qhov pits, chips, khawb, tawg, thiab lwm yam tsis xws luag. Kev khawb yog ib qho chaw ruaj khov ntawm qhov chaw; ib qho tsis xws luag yog ib qho uas tsis yog-linear xws li cov khib nyiab lossis lub qhov. Qhov kev lees paub qhov txwv yog nyob ntawm qhov siv tau txuas interface thiab hom fiber ntau. Siv tus qauv tam sim no thiab kev tshuaj xyuas qhov kev pom zoo 2022 profile es tsis yog siv ib qho kev sib tw thoob ntiaj teb rau txhua qhov txuas.

 

 

Yog vim li cas xyoo 2022 tsab hloov qhov kev txiav txim siab teb

Qhov kev hloov pauv tseem ceeb tshaj plaws yog kev sib raug zoo ntawm kev tshuaj xyuas qhov muag thiab kev ua haujlwm kho qhov muag. IEC 61300-3-35: 2022 hais tias lub connector yuav tsum tsis txhob raug tso tseg nkaus xwb vim nws tsis pom kev tshuaj xyuas. Yog hais tias cov kab mob xoob xoob tau hais txog thiab cov khoom txuas tseem qhia pom qhov tsis xws luag, nws qhov kev ua tau zoo kho qhov muag tau dhau los ua ib feem ntawm kev txiav txim siab tsim nyog. Attenuation thiab rov poob poob tseem cais qhov kev ua tau zoo uas yuav tsum tau ntsuas raws li cov kev qhia tshwj xeeb.

Qhov no tsis tau txhais hais tias lub cev qias neeg lossis lub cev puas yuav tsum tau sib txuas. Cov kab mob xoob tuaj yeem hloov mus rau qhov kawg ntawm lub ntsej muag, thiab kev cuam tshuam puas tuaj yeem tsim teeb meem ntxiv. Qhov kev txhais lus raug yog nqaim dua: qhov pom FAIL tsis tau txiav txim siab seem. Ua raws li tus txheej txheem kev tshuaj xyuas thiab tu cov txheej txheem, tom qab ntawd ua qhov kev ntsuas kho qhov muag uas xav tau los ntawm cov khoom siv, cov khoom siv, thiab qhov project specification ua ntej txiav txim siab seb lub connector puas siv tau.

Fluke Networks 'explanation of theKev hloov pauv rau IEC 61300-3-35yog qhov muaj txiaj ntsig keeb kwm yav dhau los ntawm tsab thib peb. Daim ntawv tshaj tawm IEC tseem yog kev tswj xyuas rau tus qauv nws tus kheej.

 

 

Khaws ib leeg-Fiber thiab MPO cov txheej txheem tshuaj xyuas cais

LC, SC, FC, thiab ST connectors nquag siv ib qho cylindrical ferrule interface. MPO connector siv lub duab plaub ntau fiber ntau ferrule nrog ib tug array ntawm ib tug neeg fiber ntau txoj hauj lwm. Tib tus qauv npog ob hom kev sib txuas, tab sis qhov chaw soj ntsuam, sojntsuam, ntxuav cov cuab yeej, thiab cov ferrule-theem checks tsis hloov pauv.

Kab lus no hais txog ib leeg-fiber connectors nkaus xwb. Rau kev sib dhos MPO, tshawb xyuas tag nrho cov duab plaub thiab cov haujlwm fiber ntau uas siv MPO-tshaj kev tshuaj xyuas thiab cov txheej txheem tu. Saib DIMI cov lus qhia cais rauMPO connector tu thiab kuajrau kev ua haujlwm ntau fiber ntau.

 

 

Npaj cov cuab yeej tshuaj xyuas thiab chaw ua haujlwm

Ua ntej kuaj xyuas lub connector, paub meej tias cov cuab yeej tsim nyog rau lub connector raug kuaj. Lub tshuab ntsuas hluav taws xob yuav tsum muaj qhov kev tshuaj ntsuam xyuas kom raug lossis kho kom raug, thaj chaw txaus ntawm kev pom thiab kev daws teeb meem rau cov qauv siv tau, thiab kev txheeb xyuas qhov profile uas sib phim IEC 61300-3-35: 2022. Magnification ib leeg tsis ua pov thawj tias qhov kev tshuaj ntsuam xyuas tau ua raws. Tshawb xyuas cov ntaub ntawv ntsuas rau cov kev txhawb nqa txuas, hom fiber ntau, thiab cov qauv qauv.

  • Siv cov lus piav qhia kom raug.LC thiab lwm yam kev sib txuas me me tuaj yeem xav tau cov khoom sib txawv ntawm SC, FC, lossis ST connectors. Ib qho lus qhia uas tsis yog lub rooj zaum tuaj yeem tsim cov duab tsis tiav lossis tsis meej pem.
  • Tshawb xyuas lub mating receptacle nrog rau lub ntsaws.Lub tes tsho Adapter, vaj huam sib luag chaw nres nkoj, thiab cov khoom siv cuam tshuam tuaj yeem tuav cov kab mob sib kis uas hloov mus rau qhov sib txuas huv.
  • Tiv thaiv cov cuab yeej tshuaj xyuas.Ib qho kev sojntsuam qias neeg tuaj yeem ua rau cov khoom sib txuas huv huv tuaj yeem pom muaj kab mob. Ua raws li cov chaw tsim khoom tsim cov txheej txheem rau kev ntxuav thiab tshuaj xyuas nws tus kheej optical interface.
  • Tswj optical kev nyab xeeb.Tsis txhob saib ncaj qha mus rau hauv qhov muaj peev xwm ua haujlwm fiber ntau nrog lub tshuab tsom saib ncaj qha. Paub meej tias cov fiber ntau tsis nqa lub hwj chim kho qhov muag, los yog siv qhov kev tshuaj ntsuam xyuas video uas tsim nyog lossis lub tshuab ntsuas qhov muag nrog qhov yuav tsum tau muaj kev tiv thaiv infrared.
  • Khaws thaj chaw ua haujlwm tswj.Khaws cov khoom siv tsis siv thiab cov chaw nres nkoj capped, tsis txhob kov ferrule kawg lub ntsej muag, thiab siv cov ntaub ntawv ntxuav uas npaj rau fiber-optic interfaces.

Lub koom haum Fiber OpticFOA-8 kev tshuaj xyuas thiab tu tus qauvmuab cov kev taw qhia ua haujlwm ntawm kev teeb tsa lub tshuab tsom, kev sib txuas ntawm kev tu, thiab cov ntaub ntawv tshuaj xyuas. Nws2025 installation txheemkuj tseem hais txog kev tshuaj xyuas cov khoom sib txuas thiab kev kuaj xyuas-fiber.

 

 

Lub Six-Step Field Txais Kev Ua Haujlwm

1. Txheeb xyuas qhov txuas thiab qhov yuav tsum tau txais

Sau cov cable lossis sib dhos ID, fiber ntau ID, qhov chaw nres nkoj, tsev neeg txuas, hom fiber ntau, thiab polish teev rau kev sib txuas. Paub meej qhov kev lees paub specification ua ntej kuaj. Lub microscope profile xaiv rau qhov tsis ncaj ncees lawm fiber ntau lossis connector tuaj yeem tsim qhov tsis tsim nyog txawm tias cov duab pom meej.

Tsis txhob suav cov polish los ntawm cov xim ib leeg thaum muaj cov ntawv sib dhos, kos duab, lossis cov ntaub ntawv khoom siv. Paub meej tias cov mating interfaces tau sib xws. Piv txwv li, UPC thiab APC lub ntsej muag kawg tsis yog qhov sib hloov ntawm cov mating; kev tshuaj xyuas qhov muag tsis ua rau ib khub tsis sib haum.

2. Ua kom muaj kev soj ntsuam zoo thiab ruaj khov

Paub meej tias cov fiber ntau muaj kev nyab xeeb los kuaj xyuas. Ruaj ntseg lub connector nyob rau hauv qhov tseeb fixture, xaiv qhov sib txuas sojntsuam cov lus qhia, thiab xyuas kom meej tias cov duab yog teem thiab nruab nrab. Yog tias lub tshuab ntsuas tshuab siv qhov ntsuas tsis siv neeg, xaiv IEC 61300-3-35: 2022 profile thiab qhov raug txuas / fiber ntau teeb tsa ua ntej sau cov txiaj ntsig.

3. Tshawb xyuas ua ntej ntxuav

Tshawb xyuas lub ntsej muag kawg ua ntej siv tshuaj ntxuav. Saib thoob plaws thaj chaw sib cuag rau cov khoom xoob lossis cov seem, tom qab ntawd tshuaj xyuas cov tub ntxhais thiab cladding thaj chaw rau khawb thiab qhov tsis xws luag. Khaws ib daim duab thaum cov txheej txheem tshuaj xyuas yuav tsum muaj pov thawj traceable.

Tshawb xyuas ob sab ntawm qhov xav tau kev sib txuas. Ib lub tshuab hluav taws xob huv huv tuaj yeem raug paug tam sim ntawd los ntawm lub tes tsho qias neeg adapter lossis khoom siv chaw nres nkoj. Tib lub hauv paus ntsiab lus siv rau kev sim cov hlua siv thiab cov khoom siv sib txuas: cov kev ntsuas ntsuas suav nrog ntau dua li cov khoom siv cable ib leeg.

4. Ntxuav tsuas yog thaum kuaj pom tias yuav tsum tau ntxuav

Yog hais tias tshem tau cov kab mob, siv ib txoj kev tu thiab cov cuab yeej pom zoo rau lub connector thiab interface. Ua raws li cov chaw tsim tshuaj ntxuav cov lus qhia rau qhov chaw tiv tauj, siab, txav, thiab cov kua dej pom zoo. Tsis txhob xav tias ib txoj kev ntxuav yog tsim nyog rau txhua LC, SC, FC, lossis ST interface.

Zam tsis txhob siv cov ntaub ntawv improvised, rov siv dua cov ntaub so, thiab daim ntawv thov hnyav hnyav. Tsis txhob tsuag cov kua dej rau hauv ib qho txuas lossis ib lub tshuab nqus tsev ntxhua khaub ncaws tshwj tsis yog lub tuam txhab tsim khoom qhia meej meej rau koj ua li ntawd. Yog tias cov kab mob sib kis tau nyob hauv qhov chaw nres nkoj los yog cov khoom siv, siv cov cuab yeej ntxuav qhov chaw nres nkoj tsim kom ncav cuag qhov kev sib tshuam.

Kev ntxuav tsis tsim nyog tsis yog ib qho kev tswj kom zoo. Kev ntxuav nws tus kheej qhia kev tuav thiab tuaj yeem tawm cov khoom seem lossis nyiam cov khoom tshiab. Tshawb xyuas ua ntej, ntxuav thaum tsim nyog, thiab tshuaj xyuas dua.

5. Rov tshuaj xyuas siv qhov kev lees paub tam sim no

Tom qab ntxuav, rov tshuaj xyuas tib lub ntsej muag kawg thiab cov mating interface. Paub meej tias cov khib nyiab tshem tau raug tshem tawm thiab qhov seem ntawm qhov chaw tau raug soj ntsuam siv qhov tseeb 2022 cov qauv. Txuag cov duab tom qab huv si thiab cov txiaj ntsig tshuaj xyuas thaum xav tau kev taug qab.

Yog hais tias rov ntxuav dua tsis hloov lub cim, tsis txhob txuas ntxiv mus rau lub voj voog uas tsis muaj kev tswj xyuas thiab tshuaj xyuas. Txiav txim siab seb tus yam ntxwv puas yog cov khib nyiab pov tseg, khawb mus tas li, nti, lossis lub cev puas tsuaj. Ua raws li tus qauv tam sim no thiab cov txheej txheem kev teeb tsa es tsis ua ntsiag to overriding qhov ntsuas qhov tshwm sim.

6. Siv qhov kev ntsuam xyuas qhov muag pom thaum qhov pom kev pom tsis haum

Yog hais tias lub connector tseem ua tsis tau raws li cov kev pom kev siv tau tom qab tshem tawm cov kab mob sib kis tau, ua qhov kev ntsuas kho qhov muag xav tau los ntawm cov khoom siv lossis qhov project specification. Cov no tuaj yeem suav nrog kev ntsuas qhov qis lossis qhov ntsuas qhov ntsuas qhov poob thiab rov qab ntsuas qhov poob, nyob ntawm qhov cuam tshuam thiab daim ntawv thov.

Sib piv cov nqi ntsuas nrog cov kev txwv tiag tiag. Tsis txhob hloov tus lej kev lag luam generic rau ib daim ntawv teev cov khoom, cov neeg siv khoom xav tau, lossis cov qauv kev pom zoo. Yog tias qhov kev ua haujlwm kho qhov muag ua tau raws li qhov yuav tsum tau ua, IEC 61300-3-35: 2022 muab rau cov khoom sib txuas kom pom tau tias tsim nyog txawm tias qhov kev soj ntsuam pom ib leeg yuav txwv tsis pub tawm. Sau cov txiaj ntsig pom thiab kho qhov muag sib cais, thiab tau txais ib qho kev pom zoo uas yuav tsum tau muaj rau qhov teeb meem.

 

 

Kev tshuaj xyuas qhov muag, kev ntsuam xyuas cov khoom, thiab cov ntawv pov thawj txuas sib txawv

Cov tshev no teb cov lus nug txawv engineering. Kev hla ib qho tsis tuaj yeem ua pov thawj tias lwm tus tau dhau lawm.

Tshawb xyuas Cov lus nug teb Dab tsi nws tsis ua pov thawj
Kev tshuaj xyuas lub ntsej muag kawg Puas yog kev kis kab mob, khawb, thiab qhov tsis xws luag nyob rau hauv cov qauv kev kuaj pom? Nws tsis lees paub lub connector qhov kev nkag tsis tau, rov qab poob, lossis qhov txuas tiav.
Connector lossis Cheebtsam kho qhov muag kuaj Puas yog qhov ntsuas qhov muag pom tau raws li cov khoom siv lossis cov khoom siv tshwj xeeb? Nws tsis hloov kev tshuaj xyuas rau cov kab mob xoob xoob uas tuaj yeem txav mus los lossis ua rau lub mating nto.
OLTS link test Puas yog qhov txuas txuas fiber ntau ua tau raws li nws qhov kawg-rau-kawg qhov yuav tsum tau ua raws li cov txheej txheem siv? Nws tsis txheeb xyuas txhua qhov kawg ntawm lub ntsej muag tsis xws luag lossis nrhiav txhua qhov xwm txheej ntawm txoj kev.
OTDR characterization Qhov twg raws txoj kev fiber ntau yog qhov poob lossis qhov kev xav yuav tshwm sim? Nws tsis yog qhov hloov pauv rau qhov xav tau qhov kawg-rau-kawg qhov kev xeem poob lossis kev tshuaj xyuas lub ntsej muag kaw.

Rau cov chaw teeb tsa cable, txoj kev sim thiab kev siv cov teeb tsa yuav tsum ua raws li tus qauv tsim nyog. FOA kev taw qhia kev teeb tsa piav qhia txog kev ntsuas qhov tsis pom kev nrog lub hauv paus thiab lub ntsuas hluav taws xob / OLTS raws li kev sim teb, nrog OTDR siv thaum qhov xwm txheej qhov chaw lossis cov ntaub ntawv daws teeb meem xav tau. Khaws cov txiaj ntsig no cais los ntawm cov khoom txuas cov ntaub ntawv soj ntsuam pom.

 

 

Dab tsi yuav suav nrog hauv Cov Ntaub Ntawv Txais Kev Sib Txuas

Cov ntaub ntawv muaj txiaj ntsig ua rau lwm tus kws tshaj lij nkag siab txog yam tau tshuaj xyuas, cov txheej txheem twg raug siv, qhov raug ntxuav, thiab vim li cas cov khoom txuas tau txais lossis tsis lees txais. Ib qho PASS / FAIL screenshot tsis muaj cov ntsiab lus nyuaj rau kev tshuaj xyuas tom qab.

Sau cov khoom Cov ntaub ntawv khaws cia
Kev txheeb xyuas Qhov project, cable/assembly ID, fiber ntau ID, connector sab, vaj huam sib luag los yog khoom chaw nres nkoj.
Interface Connector tsev neeg, hom fiber ntau, polish, thiab mating-interface cov ntsiab lus tau lees paub los ntawm daim duab lossis daim ntawv lo.
Kev tshuaj ntsuam xyuas Microscope qauv, sojntsuam cov lus qhia, tsom xam profile, qauv qauv, thiab hnub tshuaj xyuas.
Cov pov thawj pom Ua ntej ntxuav thiab tom qab ntxuav cov duab thaum xav tau, tshuaj ntsuam xyuas, thiab sau ntawv ntawm qhov tsis xws luag.
Kev ntxuav tu Cov cuab yeej thiab txoj kev pom zoo siv, tus naj npawb ntawm kev sim, thiab seb qhov chaw nres nkoj mating lossis adapter kuj tau txais kev pabcuam.
Optical tshwm sim Kev xeem txoj kev, siv configuration, wavelength qhov twg muaj feem xyuam, ntsuas tau, thiab cov specification siv rau kev sib piv.
Kev cai Txais, tsis lees paub, kho, lossis xa mus rau kev tshuaj xyuas; suav nrog tus neeg teb xov tooj, hnub tim, thiab cov neeg siv khoom xav tau lossis kev pom zoo engineering.

 

 

Kev soj ntsuam thiab lees txais yuam kev

  • Siv 2015 kev soj ntsuam profile rau 2022 qhov yuav tsum tau txais.Txheeb xyuas qhov tsab ntawv thiab muab qhab nia profile ua ntej ntsuas qhov tshwm sim.
  • Tshawb xyuas tsuas yog lub ntsaws ntsaws.Lub mating adapter, cov khoom siv chaw nres nkoj, thiab cov ntaub ntawv pov thawj kev sib txuas tuaj yeem rov ua kom huv lub ntsej muag.
  • Ntxuav txhua txhua connector txiav.Kev tshuaj xyuas yuav tsum txiav txim siab seb puas tsim nyog tu; kev tuav tsis tsim nyog tuaj yeem qhia txog kev sib kis.
  • Kho qhov pom PASS raws li daim ntawv pov thawj txuas.Lub ntsej muag huv huv tsis ua pov thawj tias qhov txuas txuas ua tau raws li nws cov peev nyiaj poob.
  • Kho qhov muag pom FAIL li tsis siv neeg seem.Tom qab xoob kev sib kis tau hais, siv txoj kev kho qhov muag-kev ua tau zoo xav tau los ntawm IEC 61300-3-35: 2022 thiab qhov project specification.
  • Siv tib qho kev sojntsuam thiab ntxuav rau txhua hom kev sib txuas.Muab cov lus tshuaj ntsuam xyuas thiab ntxuav cov cuab yeej mus rau qhov txuas thiab qhov chaw nres nkoj recessed.
  • Saib mus rau hauv ib qho active fiber nrog ib qho kev tiv thaiv kab mob optical.Txheeb xyuas qhov muag pom kev nyab xeeb ua ntej kev tshuaj xyuas thiab siv cov khoom siv yees duab tsim nyog lossis lim dej.

 

 

Yuav ua li cas qhov no haum rau kev xaiv Connector

Kev tshuaj xyuas lub ntsej muag kawg yog qhov kev lees paub thiab kev saib xyuas, tsis yog qhov hloov pauv rau kev xaiv tsev neeg txuas kom raug. Connector xaiv tseem nyob ntawm cov khoom siv interface, fiber ntau hom, polish, mechanical coupling, vaj huam sib luag ntom, thiab ib puag ncig installation. Rau kev sib piv dav dav ntawm LC, SC, FC, ST, thiab MPO / MTP interfaces, saib DIMI'sfiber optic connector hom qhia. Rau kev xaiv connector thiab cov khoom nug, mus saib ntawmfiber optic connector qeb.

 

 

FAQ

Q: Puas yog IEC 61300-3-35: 2022 ntsuas qhov poob?

A: Tsis yog. Nws txhais cov txheej txheem tshuaj xyuas qhov muag thiab cov qauv kev huv. Attenuation / insertion poob thiab rov qab poob yog qhov kev ua tau zoo ntawm qhov muag thiab yuav tsum tau ntsuas los ntawm kev siv cov qauv ntsuas thiab cov lus qhia tshwj xeeb.

Q: Puas yog qhov pom kev tsis pom kev txhais tau hais tias lub connector yuav tsum tau hloov?

A: Tsis tau. Thawj qhov chaw nyob uas tshem tau cov kab mob thiab ua raws li cov txheej txheem tshuaj xyuas tam sim no. Yog tias qhov pom tshwm sim tseem ua tsis tiav thiab tsis muaj cov khib nyiab xoob, sim lub connector tiv thaiv nws qhov kev ua haujlwm kho qhov muag teev. Qhov kev txiav txim siab zaum kawg yuav tsum hwm txhua yam kev puas tsuaj ntawm lub tshuab thiab qhov kev lees paub ntawm qhov project.

Q: Puas yuav tsum tau ntxuav lub connector yog tias nws dhau kev tshuaj xyuas?

A: Tsis tau. Yog tias lub ntsej muag kawg dhau qhov kev tshuaj ntsuam xyuas thiab tsis muaj qhov paug tawm, kev ntxuav tsis tsim nyog ntxiv kev tuav thiab tuaj yeem qhia cov khib nyiab tshiab. Ua raws li cov txheej txheem pom zoo.

Q: Kuv puas yuav tsum tau kuaj xyuas qhov chaw nres nkoj adapter nrog rau lub connector?

A: Yog. Tshawb xyuas lub ntsej muag kawg ntawm lub ntsej muag thiab lub ntsej muag sib txuas nrog cov kev sojntsuam tsim nyog thiab cov cuab yeej ntxuav chaw nres nkoj. Lub tes tsho adapter tsis muaj kab mob lossis cov khoom siv chaw nres nkoj tuaj yeem hloov cov khib nyiab mus rau qhov sib txuas huv.

Q: Puas yog qhov kev ua haujlwm no siv rau MPO connectors?

A: Tsis yog. MPO connectors siv lub duab plaub ntau fiber ntau ferrule thiab xav tau ib qho kev tshuaj xyuas thiab tu cov cuab yeej haum rau tag nrho ferrule thiab ib tug neeg fiber ntau txoj hauj lwm. Siv cov txheej txheem MPO nplooj siab es tsis yog siv ib qho kev sojntsuam ua haujlwm.

 

Xa kev nug