Specifications Txheej txheem cej luam
Khoom kos duab



Cable Configuration
| Connector A | MPO/MTP Poj Niam (12-fiber, tsis-pinned lossis pinned yeem) |
| Connector B | 8 × FC / APC lossis 12 × FC / APC Simplex |
| Hom Fiber | OS2 Single Mode 9/125µm |
| Fiber suav | 8-fiber los yog 12-fiber breakout |
| Kab Kab | Round lub cev cable nrog fanout ob txhais ceg |
| Lub cev Cable Diameter | 3.0mm ± 0.1 hli |
| Fanout Leg Diameter | 0.9mm los yog 2.0mm nruj -buffered |
| Fanout Length | 0.5m, 1.0m, los yog kev cai (los ntawm breakout khau raj) |
| Jacket Rating | LSZH (default), OFNP, PVC yeem |
| Ua haujlwm kub | -20℃rau +70 degree |
| Cia Kub | -40℃rau +85 degree |
| Txheem Xim | Yellow (OS2), Dub (sab nraum zoov) |
Optical Performance
| Parameter | Tib hom (OS2) |
| Insertion Loss (MPO sab) | Tsawg dua lossis sib npaug rau 0.35 dB (ib khub niam txiv) |
| Insertion poob (FC/APC sab) | Tsawg dua los yog sib npaug rau 0.30 dB (ib qho txuas) |
| Rov Los Loss (MPO) | Ntau dua lossis sib npaug rau 45 dB (UPC qib) |
| Rov Los Loss (FC/APC) | Ntau dua lossis sib npaug li 60 dB |
| Fiber ntau attenuation | Tsawg dua lossis sib npaug rau 0.35 dB / km @ 1310nm, Tsawg dua lossis sib npaug rau 0.25 dB / km @ 1550nm |
| Ua haujlwm Wavelength | 1260-1625 nm |
Qauv & Polarity
Cable Structure Description

Lub MPO/MTP rau FC/APC breakout cable nta lub cev muaj zog puag ncig lub cev (feem ntau 3.0mm txoj kab uas hla) vaj tse 8 los yog 12 ib leeg - hom fibers. Ntawm qhov kawg, fibers xaus rau hauv 12- txoj haujlwm MPO / MTP poj niam txuas nrog cov pins sib dhos (lossis tsis yog pinned version).
Ntawm qhov kawg ntawm qhov kawg, ib tus neeg fibers kiv cua tawm los ntawm kev tiv thaiv kev tiv thaiv khau raj, txhua qhov xaus nrog ib qho yooj yim FC / APC connector. Fanout ob txhais ceg muaj nyob rau hauv 0.9mm los yog 2.0mm nruj -buffered designs nrog standard lengths ntawm 0.5m los yog 1.0m los ntawm khau raj.
Txhua FC/APC ceg tau sau meej meej nrog cov lej sib txuas (Fiber 1, Fiber 2, … Fiber 8/12) sib raug rau MPO fiber ntau txoj haujlwm. Cov khau boots ntev ntev ntawm MPO thiab FC xaus tiv thaiv kev khoov -kev ntxhov siab. Optional tiv thaiv plua plav hau rau FC/APC connectors thiab MPO kawg-lub ntsej muag yog suav nrog.
Daim ntawv thov

Data Center Migration ntawm FC rau MPO Infrastructure
Ua kom muaj qub txeeg qub teg ib leeg - cov cuab yeej siv nrog FC/APC interfaces txuas mus rau niaj hnub siab - ntom ntom MPO / MTP lub cev pob txha, pab txhawb kev hloov kho hauv lub network yam tsis muaj kev hloov khoom tiav.

DWDM thiab Optical Transport Networks
APC qis- qhov cuam tshuam cuam tshuam ua rau cov cables zoo tshaj plaws rau kev txuas DWDM mux/demux units, optical amplifiers, thiab OTDR test equipment to MPO-raws li fiber distribution systems in metro and long-haul networks.

Kev ntsuas thiab ntsuas ntsuas
Muab cov kev sib txuas yooj yim sib txuas rau cov khoom siv kho qhov muag uas xav tau ib tus neeg FC / APC cov chaw nres nkoj thaum koom nrog MPO thaj vaj huam sib luag, zoo tagnrho rau cov chaw kuaj mob thiab cov xwm txheej sim.

Fiber Distribution los ntawm MDA / HDA
Nyob rau hauv cov qauv cabling tsim raws li TIA-942 tus qauv, cov cables no faib ib tug tib neeg ib leeg - hom fiber ntau txuas los ntawm MPO-raws li Main Distribution Areas (MDA) los yog Kab rov tav Distribution Areas (HDA) mus rau cov khoom siv racks uas yuav tsum muaj kev sib txuas ntawm FC/APC.
Factory xeem txheej txheem
3D Interferometer Endface soj ntsuam
Tag nrho MPO thiab FC/APC connector endfaces soj ntsuam ib IEC 61300-3-35 los xyuas cov geometry tsis (lub vojvoog ntawm curvature, apex offset, fiber ntau qhov siab) thiab xyuas kom meej qhov huv si lub rooj sib tham IEC 61300-3-35 Qib A.
Insertion Loss Testing
Txhua tus neeg fiber ntau txuas tau kuaj ntawm 1310nm thiab 1550nm wavelengths siv cov cuab yeej ntsuas ntsuas. Cov txiaj ntsig tau sau nrog tus lej serial traceability.
Rov qab Loss Verification
FC/APC connectors tau txheeb xyuas kom tau raws li ntau dua lossis sib npaug ntawm 60dB rov qab cov ntsiab lus tsis zoo siv OTDR lossis kho qhov muag rov qab cov khoom poob, kom ntseeg tau tias tsim nyog rau siab - daim ntawv thov kev ua tau zoo.
Polarity & Continuity Verification
Kev ntsuas polarity tsis siv neeg lees paub qhov tseeb fiber ntau daim ntawv qhia los ntawm MPO txoj haujlwm mus rau FC / APC ob txhais ceg, nrog rau kev pom lub teeb pom kev rau kev tshawb pom qhov txhaum sai.
Customization Options
Ntev Flexibility
Txhua qhov ntev ntawm 1 txog 100 meters; ntev ntev muaj nyob rau sab nraum zoov lossis tsev kawm ntawv daim ntawv thov nrog tsim nyog cable
Xaiv Length (meter)
01
Fiber Hom Options
OS2 ib hom (tus qauv), nrog rau khoov -insensitive G.657.A2/B3 fibers rau nruj routing daim ntaub ntawv
02
Fiber suav Configurations
8-fiber lossis 12-fiber tus qauv; 24-fiber breakout muaj siv dual MPO connectors los yog ribbon cable siv
03
Connector Polish Hom
FC / APC (8℃kaum sab xis, tus qauv) lossis FC / UPC (lub cev tiv tauj); MPO muaj nyob rau hauv UPC lossis APC polish.
04
MPO Pin Configuration
Poj niam nrog tus pins (pinned), poj niam tsis muaj pins (non-pinned), lossis txiv neej connectors kom phim mating infrastructure
05
Jacket Ratings
LSZH nplaim taws-retardant (tus qauv), OFNP plenum- ntsuas rau qhov chaw tuav huab cua, PVC rau kev siv dav dav, lossis sab nraum zoov- ntsuas nrog armored / gel- ua tiav kev tsim kho
06
Fanout Options
Breakout ceg ntev (0.5m, 1.0m, los yog kev cai), ceg txoj kab uas hla (0.9mm los yog 2.0mm), thiab breakout khau raj txoj hauj lwm yuav tsum tau teev.
07
Labeling & Marking
Cov ntawv cim kab kev cai, cov qauv sib txuas fiber ntau, cov cuab yeej cim npe, thiab xim - cov khau khiab muaj rau kev qhia yooj yim thiab kev tswj xyuas
08
Yam khoom & Accessories

MPO / MTP Cassette Modules
High-cov cassettes ceev hloov MPO lub cev sib txuas rau LC, SC, lossis FC duplex chaw nres nkoj rau kev teeb tsa kev siv cabling

MPO / MTP Fiber Patch Vaj Huam Sib Luag
1U thiab 2U khib-mount panels nrog MPO adapter daim hlau rau centralized cross-txuas kev tswj kev txhawb nqa mus txog 144 fibers ib RU

MPO/MTP Cov cuab yeej ntxuav
Cov tshuaj ntxuav tshwj xeeb suav nrog ib qho -nias MPO cov ntxhua khaub ncaws, ntxuav cov cassettes, thiab lint - cov ntaub so pub dawb rau kev tswj xyuas qhov zoo tshaj plaws connector endface

FC/APC Optical Adapters
Simplex thiab duplex FC/APC bulkhead adapters rau vaj huam sib luag mounting, muaj nyob rau hauv bronze tes tsho (tus qauv) los yog ceramic tes tsho (siab-kev ua tau zoo) versions

MPO / MTP Loopback Modules
Kev ntsuam xyuas thiab kuaj xyuas cov khoom siv rov qab rau 8-fiber, 12-fiber, thiab 24-fiber MPO interfaces txhawb kev daws teeb meem hauv network thiab khoom siv siv tau

Cable Management Accessories
Breakout khau boots, strain relief khau looj plab hlaub, tiv thaiv kaus mom, cable ties, thiab labeling tshuab rau kev installation tiav
Cim npe nrov: mpo/mtp cables-fc/apc-sm-8/12 fibers, Tuam Tshoj mpo/mtp cables-fc/apc-sm-8/12 fibers manufacturers, lwm tus neeg, Hoobkas