OM3 vs OM4: Siv OM4 rau Cov Chaw Cov Ntaub Ntawv Tshiab

May 16, 2026

Tso lus

OM4 fiber ntau muaj ntau dua ob npaug ntawm qhov ua tau zoo ntawm kev siv bandwidth ntawm OM3 thiab txhawb nqa ntev dua ntawm 10G, 25G, 40G thiab 100G. OM3 tseem yog ib qho kev xaiv zoo rau kev txuas luv luv thiab pob nyiaj siv -sensitive 10G networks. Rau feem ntau cov ntaub ntawv tshiab cabling, OM4 yog qhov kev nyab xeeb ntev dua - lub sij hawm txiav txim siab.

OM3 thiab OM4 yog ob qho tib si laser- optimized 50/125 µm multimode fibers, tsim rau luv luv - wavelength VCSEL transceivers ntawm 850 nm. Lawv yog ob hom multimode ntau tshaj plaws nyob rau hauv cov chaw zov me nyuam niaj hnub, kev lag luam LANs, thiab cov chaw cia khoom. Qhov kev xaiv yog nyob ntawm koj lub transceiver, txuas ntev, hom connector, insertion poob nyiaj, thiab sai npaum li cas koj npaj yuav txav mus rau 25G, 40G, 100G, lossis siab dua.

OM3 and OM4 multimode fiber cables in a data center@dimifiber

OM3 vs 4

Siv OM3 fiber ntau thaum koj cov kev sib txuas luv luv, koj tab tom khiav 10G Ethernet lossis luv 40G / 100G daim ntawv thov, thiab koj twb muaj OM3 infrastructure lossis pob nyiaj nruj.

Siv OM4 fiber ntau thaum koj tab tom txhim kho cov cabling tshiab, npaj siab dua - hloov kho kom nrawm dua, lossis xav tau cov kab sib txuas ntxiv rau qhov sib npaug -optic 40G thiab 100G txuas.

Yog tias koj qhov txuas yuav dhau li ntawm 100 m ntawm 40G / 100G, lossis 400 m ntawm 10G, tsis yog OM3 lossis OM4 tsis haum - koj yuav tsum ntsuassingle-mode piv rau multimode transceiversxwb.

OM3 thiab OM4 Fiber ntau yog dab tsi?

OM3 thiab OM4 yog ob qho tib si 50/125 µm laser -optimized multimode fibers (LOMMF) txhais hauvISO / IEC 11801 Kev Tswj Xyuas Kev Lag Luamand TIA-492AAAC/AAAD. Lawv sib faib cov tub ntxhais loj loj thiab sab nraud, thiab lawv tuaj yeem siv tib lub txuas thiab thaj vaj huam sib luag. Qhov txawv yog bandwidth kev ua tau zoo, tshwj xeeb tshaj yog laser-launchSiv tau Modal Bandwidth (EMB)ua 850nm.

  • OM 3:Yam tsawg kawg nkaus EMB ntawm 2,000 MHz ·km ntawm 850 nm
  • OM4:Yam tsawg kawg nkaus EMB ntawm 4,700 MHz ·km ntawm 850 nm

Qhov sib txawv ntawm qhov bandwidth yog tag nrho vim li cas OM4 txhawb nqa ntev dua ntawm tib lub Ethernet ceev. Cov iav tseem ceeb, qhov sib txuas geometry, thiab kev coj ua huv si yog lwm yam zoo ib yam - uas yog vim li cas OM3 thiab OM4 yog lub cev sib cuam tshuam tab sis tsis sib npaug hauv kev ua haujlwm.

OM3 Fiber hauv kev xyaum

OM3 tau siv dav hauv 10G Ethernet tes hauj lwm thiab luv luv - mus txog cov ntaub ntawv chaw txuas. Nws feem ntau muaj aqua- lub tsho muaj xim, txawm hais tias daim npav luam ntawv yog tus cim kev ntseeg tau nkaus xwb. OM3 yog qhov kev xaiv zoo thaum:

  • Cov kev sib txuas khiav ntawm 10G Ethernet hla qhov deb zoo hauv qab 300 m
  • 40G lossis 100G txuas yog luv (hauv qab 70-100 m)
  • Cov phiaj xwm nyiaj txiag nruj thiab cov phiaj xwm kev ceev yog ruaj khov
  • OM3 infrastructure twb muaj lawm thiab ua tau zoo

OM4 Fiber hauv kev xyaum

OM4 yog qhov kev xaiv ntau hom rau kev lag luam tshiab thiab cov ntaub ntawv chaw cabling hnub no. Nws txhawb nqa tib daim ntawv thov raws li OM3, tab sis nrog ntau qhov ncav cuag. OM4 yog qhov xaiv zoo thaum:

  • Koj tab tom rub cov fiber ntau tshiab uas yuav nyuaj los hloov tom qab
  • Cov cabling yuav pom 40G, 100G, lossis dhau ntawm nws lub neej
  • Cov kev sib txuas yog nyob ze rau OM3 lub qab nthab thiab koj xav tau lub taub hau rau thaj vaj huam sib luag thiab cov khoom sib txuas
  • Koj ua haujlwm siab -cov ntaub ntawv ceev ceev nrog cov qauv cabling thiab ntau tus ntoo khaub lig- txuas

    Technical comparison of OM3 and OM4 multimode fiber cables

OM3 vs OM4 Sib piv Table

Specification OM3 Fiber ntau OM4 Fiber ntau
Fiber hom Laser - optimized multimode Laser - optimized multimode
Core / cladding loj 50/125 µm 50/125 µm
Ua haujlwm wavelength 850nm (kuj 1310nm) 850nm (kuj 1310nm)
Yam tsawg kawg nkaus EMB ntawm 850 nm 2,000 MHz · km 4,700 MHz · km
10GBASE-SR ncav cuag 300 m 400 m
25GBASE-SR ncav cuag 70 m 100 m
40GBASE-SR4 ncav cuag 100 m 150 m
100GBASE-SR4 ncav cuag 70 m 100 m
Xim lub tsho loj Aqua Aqua (qee tus neeg muag khoom siv erika violet)
txheeb ze tus nqi cable qis 15-40% siab dua
Zoo tshaj plaws rau 10G data center txuas, OM3 cov nroj tsuag uas twb muaj lawm Tshiab cabling, 40G / 100G luv- ncav cuag, hloov kho yooj yim

Cov duab nyob deb saum toj no ua raws li multimode ncav cuag qhov tseem ceeb tshaj tawm los ntawmIEEE 802.3Ethernet cov qauv thiab cov kev taw qhia cabling los ntawm TIA Fiber Optics Technical Consortium. Nco ntsoov lees paub qhov kev txhawb nqa deb ntawm daim ntawv teev cov ntaub ntawv tshwj xeeb ntawm cov transceiver uas koj npaj yuav siv, txij li tus neeg muag khoom- tsim nyog ncav cuag qee zaus txawv ntawm tus qauv.

OM3 vs OM4 nrug: 10G, 25G, 40G, thiab 100G ncav cuag

Qhov loj tshaj vim li cas engineers xaiv ntawm OM3 thiab OM4 yog nyob deb. Siab dua EMB cia OM4 nqa tib lub teeb liab txuas ntxiv ua ntej pulse kis (modal dispersion) corrupts tus qauv me ntsis.

10GBASE-SR

OM3 txhawb nqa txog 300 m thiab OM4 txog 400 m. Rau kev hloov- rau- server txuas hauv ib kab lossis lub tsev, ob qho tib si yooj yim mus txog. A 30 m lossis 70 m hloov- mus rau - server txuas ua haujlwm zoo ntawm OM3 nrog duplexLC connectors.

25GBASE-SR

OM3 nce mus txog 70 m, OM4 nce mus txog 100 m. Qhov poob siab yog - txav ntawm 10G mus rau 25G ntawm tib lub OM3 cabling tuaj yeem ua rau koj tsis muaj npoo ntawm cov kab txuas uas siv los ua haujlwm zoo. Yog tias koj tab tom tsim ib sab saum toj - ntawm - khib rau nplooj 25G ntaub, OM4 tiv thaiv koj los ntawm thaj ua rau thaj -vaj huam sib luag poob.

40GBASE-SR4

40G luv- ncav cuag siv 4 txoj kab sib txuas xa mus thiab 4 tau txais txoj kab hla MPO-12 txuas. OM3 txhawb 100 m, OM4 txhawb 150 m. Yog tias koj tab tom npaj 40G hla ib lub tsev ntaub ntawv, koj tab tom saibMPO / MTP thaj qaumthiab trunks - tsis duplex LC. Npaj cov hom kev sib txuas thiab cov tswv yim breakout ua ntej qhia cov fiber ntau.

100GBASE-SR4

100GBASE-SR4 kuj tseem siv 8-fiber parallel optics: OM3 txog 70 m, OM4 txog 100 m. Nyob rau hauv ib qho kev sib txuas tiag tiag nrog ob lub MPO txuas thiab ob peb lub vaj huam sib luag, qhov kev siv nyiaj poob qis tuaj yeem cuam tshuam sai sai. Rau 100G trunks saum toj no 70 m, default rau OM4 tshwj tsis yog tias koj muaj ib qho kev ntsuam xyuas OM3 cog.

Rau kev pom dav dav thoob plaws txhua qib multimode, saib peb cov ntaub ntawv sivOM1 txog OM5 multimode fiber ntau nrug txwv.
 

Multimode fiber links for 10G 25G 40G and 100G data center networks

OM3 vs OM4 Bandwidth: Vim li cas EMB teeb meem

Siv tau Modal Bandwidth ntsuas qhov zoo ntawm multimode fiber ntau khaws cia lub laser mem tes hla qhov deb. Qhov siab dua EMB txhais tau tias tsawg dua modal dispersion, uas txhais tau hais tias tus receiver tseem pom ib tug huv si "1" los yog "0" tom qab lub teeb liab mus los ntawm lub fiber.

Qhov sib txawv ntawm 2,000 vs 4,700 MHz·km tsis yog tus lej lag luam. Nws ncaj qha maps rau cov duab nyob deb saum toj no. Thaum IEEE sau qhov tshiab siab -tus qauv Ethernet ceev, qhov kev txhawb nqa multimode ncav cuag yog muab los ntawm EMB, lub transceiver's transceiver thiab tau txais cov yam ntxwv, thiab ib qho kev sib txuas ntawm cov peev nyiaj siv hluav taws xob. Cable bandwidth yog lub tswv yim; ncav cuag yog cov zis.

Qhov no kuj yog vim li cas OM3 thiab OM4 tsis yog "tsuas yog multimode." Cov laus OM1 (62.5/125 µm) thiab OM2 (50/125 µm) fibers tau optimized rau LED qhov chaw, tsis yog VCSELs, thiab lawv yuav tsis xa cov mus txog rau tag nrho. Kev sib xyaw OM1 lossis OM2 rau hauv OM3 / OM4 txoj kev yuav ua tsis tiav.

OM3 vs OM4 Tus Nqi: Thaum twg OM4 Tsim Nyog Nws?

OM4 cable feem ntau raug nqi 15-40% ntau dua OM3 ntawm tib yam kev tsim kho thiab txuas hom. Seb tus nqi them ntawd puas tsim nyog them yog nyob ntawm peb yam.

Ntev npaum li cas cov cabling yuav nyob hauv qhov chaw?Kev txuas mus tas li rub los ntawm cov kav dej, risers, lossis cov tais nyiaj siv ua haujlwm yog kim los hloov. Lub cable nws tus kheej feem ntau yog ib feem tsawg ntawm tag nrho cov nqi ntawm qhov project - ua haujlwm, downtime, thiab txoj kev nkag mus dominate. Hauv qhov xwm txheej ntawd, OM4 tus nqi ntxiv yog kev pov hwm me me rau yav tom ntej re- rub.

Txoj kev ceev yog dab tsi?Yog tias koj lub network yuav zaum ntawm 10G rau lub neej yav tom ntej thiab cov kev sib txuas luv luv, OM3 yeej txaus. Yog tias 25G lossis 40G nyob rau ntawm ob- daim ntawv qhia xyoo, OM4 them rau nws tus kheej thawj zaug qhov kev sib txuas sib txuas tawm tsam OM3 txwv.

Muaj pes tsawg connectors nyob rau hauv qhov txuas?Txhua MPO lossis LC connector ntxiv 0.25–0.75 dB ntawm kev nkag poob hauv kev teeb tsa tiag. Ib qho 100 m 100G txuas ntawm OM3 nrog ob tus ntoo khaub lig- txuas tuaj yeem ua tsis tiav kev txheeb xyuas qhov txuas thaum tib lub cable ntawm OM4 hla nrog cov npoo. Yog tias koj cov cabling tsim siv ntau lub vaj huam sib luag, OM4 yuav koj cov npoo.

Tiag -Lub Ntiaj Teb Scenarios: Xaiv OM3 lossis OM4 los ntawm Txuas Ntev

Cov rooj nrug deb yog qhov pib. Field engineers feem ntau txhais lawv rau hauv cov cai ntawm tus ntiv tes xoo raws li qhov txuas ntev thiab ceev.

  • 30 m hloov- rau- server ntawm 10G lossis 25G:OM3 zoo. Siv ib tug duplex LC thaj qaum, kom cov connectors huv si, thiab txav mus.
  • 70 m kab - mus rau - kab ntawm 25G:OM3 yog nyob ntawm ntug. Txheeb xyuas nrog OTDR lossis txuas tus ntsuas, lossis nce mus rau OM4 rau chav ua pa.
  • 100 m 40G pob tw ntawm cov kab hloov:Ob leeg ua haujlwm hauv kev xav. OM4 yog qhov ua tau zoo, tshwj xeeb tshaj yog nrog MPO breakouts ntawm txhua qhov kawg.
  • 150 m 40G campus link:OM3 yuav tsis ncav cuag. OM4 yuav, tab sis tsuas yog nrog ib tug huv ob - txuas txoj kev. Yog tias koj tus qauv tsim muaj ntau qhov sib txuas, dhia mus rau ib qho - hom.
  • Txhua yam dhau 100m ntawm 100G:Txav mus rau ib leeg -mode 100GBASE-LR4 lossis DR-class optics. Tsis txhob sim ncab OM4 dhau los nws qhov ntsuas tau ncav cuag.

Engineer's Note

Ib qho kev muaj tiag ntawm cov ntaub ntawv tsis hais txog: qhov tsis zoo ntsia OM4 txuas nrog qias neeg MPO ferrules yuav plam ntau dua dB dua li qhov txuas OM3 huv si ntawm tib qhov ntev. Fiber qeb tsis cawm qhov kev coj ua tsis zoo. Ua ntej yuav liam lub cable, tshuaj xyuas txhua qhov kawg nrog lub fiber ntau, thiab tshuaj xyuas kojkev tso nyiaj poob nyiaj. Hauv kev daws teeb meem kev mus ntsib, cov khoom siv qias neeg thiab khoov lub vojvoog ua txhaum cai rau feem ntau ntawm cov kev sib txuas tsis ua haujlwm multimode - tsis yog qhov kev xaiv ntawm OM3 vs OM4.

OM3 vs OM4 vs OM5 vs Single-Mod: Thaum twg los xav txog Txhua

OM3 thiab OM4 tsis yog tib txoj kev xaiv. Kev txiav txim siab tiav yuav tsum saib tsawg kawg ntawm OM5 thiab tib hom - hom.

  • OM 3:Pheej yig tshaj LOMMF. Txoj cai rau 10G luv txuas thiab 10G nroj tsuag uas twb muaj lawm.
  • OM4:Qhov zoo tshaj plaws sib npaug ntawm tus nqi thiab ncav cuag 25G / 40G / 100G luv txuas. Tam sim no lub neej tam sim no rau tshiab multimode cabling.
  • OM 5:Ntxiv kev ua haujlwm dav dav ntawm 850-953 nm los txhawb SWDM optics. Them tawm feem ntau qhov chaw koj xav khiav 40G lossis 100G dhau tsawg dua cov khub fiber ntau siv SWDM4. Rau feem ntau cov chaw zov me nyuam, OM4-rau-OM5 dhia yog ib qho nyuaj rau pom tseeb dua li OM3-rau-OM4 dhia.
  • Tib -mode (OS1/OS2):Tsim nyog rau kev sib txuas ntev dua, thaj chaw hauv tsev kawm lossis thaj chaw deb, thiab xa mus rau- saib 400G / 800G kev xa tawm. Cable yog pheej yig; tus nqi yog nyob rau hauv lub transceivers.

Yog tias koj hnyav ib qho - hom kom ncav cuag ntev, peb qhov kev sib piv ntawmOS1 vs OS2 single-mode fibernpog cov tswv yim sib txawv.

Koj puas tuaj yeem sib xyaw OM3 thiab OM4?

OM3 thiab OM4 yog mechanically interoperable. Lawv muab cov tub ntxhais loj loj, txuas geometry, thiab txoj kev txiav tawm. Koj tuaj yeem kho lub OM3 qaum rau hauv OM4 lub cev thiab lub teeb yuav dhau mus. Cov lus nug yog seb qhov kev sib txuas uas tshwm sim puas tseem ua tau raws li tus qauv kev ncav cuag thiab kev poob.

Thaum ib qhov txuas muaj ob ntu OM3 thiab OM4, qhov kev ua tau zoo tag nrho yog khi los ntawm qis dua - qib fiber ntau. A 100 m 40GBASE-SR4 txuas ua nrog 80 m ntawm OM4 lub cev thiab 20 m ntawm OM3 thaj cords coj zoo li OM3 dua OM4. Rau kev txuas mus tas li, khaws ib qib fiber ntau kawg -mus rau- xaus thiab sau nws. Rau ib ntus patching, kev sib tov yog qhov siv tau ntev npaum li koj rov- txheeb xyuas cov nyiaj poob haujlwm.

OM3 vs OM4 Kev txiav txim siab

Qhov project Profile Pom zoo Fiber Vim li cas
Tam sim no 10G data center, txuas hauv qab 300 m OM 3 Twb tau siv thiab nyob rau hauv ncav cuag; tsis muaj txiaj ntsig los ntawm rov- rub
Kev lag luam tshiab LAN, 10G hnub no, ua tau 25G tom qab OM 4 Pheej yig kev tuav pov hwm tiv thaiv yav tom ntej nruj txuas
Cov ntaub ntawv tshiab lub cev, 40G lossis 100G luv - ncav cuag OM 4 OM3 muaj cov npoo me me thaum txuas txuas ntxiv
Lub tsev kawm ntawv txuas tshaj 150 m ntawm 40G lossis 100G Tib - hom Tshaj multimode mus txog tsis hais qib twg
Siab- qhov chaw ntom ntom nrog ntau tus ntoo khaub lig- txuas OM4 (los yog OM5 rau SWDM) Poob nyiaj txiag teeb meem ntau dua tus nqi raw cable
Cia network, sub-50 m, 16/32G FC OM3 lub OM4 Ob leeg ua haujlwm; xaiv los ntawm pob nyiaj siv thiab cov nroj tsuag uas twb muaj lawm

Feem ntau yuam kev thaum piv OM3 thiab OM4

Piv txwv tias OM4 ib txwm xav tau.Rau 30 m 10G txuas, them tus nqi OM4 ntxiv tsis muaj txiaj ntsig tiag. Muab cov fiber ntau rau qhov nrawm thiab qhov deb, tsis yog qhov tsis paub meej "yav tom ntej- pov thawj" instinct.

Tsis quav ntsej tus qauv transceiver.Lub fiber tsuas yog ib nrab ntawm qhov txuas. Ib qho 100G-SR4 transceiver tsis coj zoo li 100G-LR4 transceiver, thiab qhov kev txhawb nqa nyob deb qhia txog optic, tsis yog lub cable xwb.

Tsis nco qab tias 100G muaj ntau yam tsw.100GBASE-SR4, SR2, SR1, DR1, FR1, thiab LR4 txhua tus nqa 100G tab sis siv ntau txoj kab suav, txuas, thiab ncav cuag. Cov fiber ntau uas ua haujlwm rau SR4 yuav tsis muaj txiaj ntsig rau LR4, thiab rov ua dua.

Overlooking connector hom.Duplex LC thiab MPO / MTP muaj qhov sib txawv patching ecosystems. Yog tias koj xaiv OM4 vim yog 100G-SR4, koj lub thaj vaj huam sib luag thiab cov cassettes kuj yuav tsum tau txhawb MPO. Rau cov ntsiab lus tob, saib peb lub ntsiab lus ntawmfiber optic connector hom.

Kev txheeb xyuas fiber ntau los ntawm lub tsho xim ib leeg.TIA-598 feem ntau muab aqua rau OM3 thiab OM4, nrog qee tus neeg muag khoom siv erika violet rau OM4 kom paub qhov txawv ntawm ob. Xim yog ib tug hint, tsis pov thawj. Ib txwm nyeem cov kab ntawv sau cov lus dab neeg.

FAQ

Q: Puas yog OM4 zoo dua OM3?

A: OM4 muaj ntau dua modal bandwidth (4,700 MHz ·km vs 2,000 MHz ·km) thiab ntev kev txhawb nqa mus txog ntawm txhua txhua multimode Ethernet ceev. Rau cov cabling tshiab, OM4 yog qhov kev xaiv zoo dua. Rau luv luv 10G txuas, OM3 feem ntau sib npaug zoo hauv kev xyaum thiab pheej yig dua.

Q: OM3 puas tuaj yeem txhawb nqa 100G?

A: Yog lawm. 100GBASE-SR4 tshaj OM3 yog nyob rau 70 m. 100GBASE-SR2 thiab SWDM-raws li 100G kuj ua haujlwm ntawm OM3 nyob rau hauv luv luv. Txhawm rau txuas 100G ntev dua, OM4 lossis ib hom - yuav tsum tau ua.

Q: OM3 thiab OM4 puas tuaj yeem sib xyaw hauv tib qhov txuas?

A: Mechanically, yog - lawv siv tib yam 50 µm core thiab connector geometry. Xyaum, qhov txuas tau txais qib qis fiber ntau ncav cuag. Tsis txhob sib xyaw ua ke hauv kev teeb tsa mus tas li, thiab ib txwm rov qab- sim cov peev nyiaj poob yog tias koj sib tov.

Q: Puas yog OM4 rov qab sib haum nrog OM3?

A: Yog. Txhua daim ntawv thov uas ua haujlwm ntawm OM3 yuav ua haujlwm ntawm OM4 nrog tsawg kawg yog tib qhov ncav cuag. Cov khoom sib txuas, cov txheej txheem sib txuas, thiab cov cuab yeej ntsuas yog tib yam.

Q: Puas yog OM3 thiab OM4 tib xim?

A: Ob leeg feem ntau yog aqua. Qee tus neeg muag khoom siv erika violet rau OM4 los ua kom pom qhov sib txawv, tab sis xim tsis yog qauv thoob ntiaj teb. Cov kab ntawv luam tawm cov cim yog tus cim tso cai.

Q: Kuv puas yuav tsum siv OM3 lossis OM4 rau lub chaw khaws ntaub ntawv?

A: Rau qhov chaw tsim cov ntaub ntawv tshiab, OM4 yog lub neej ntawd. Tus nqi fiber ntau yog me me piv rau kev ua haujlwm, txoj hauv kev, thiab yav tom ntej re- rub cov nqi. Rau qhov chaw tsim cov ntaub ntawv nrog kev ruaj ntseg 10G tsheb, nthuav nrog OM3 yog qhov tsim nyog.

Q: Kuv puas yuav tsum hla multimode thiab mus rau ib qho -hom?

A: Ib qho - hom cable yog pheej yig dua OM4, tab sis ib leeg - hom transceivers raug nqi ntau dua, tshwj xeeb tshaj yog nyob rau hauv siab dua. Rau sub{10}}100 m data center txuas ntawm 10G–100G, multimode feem ntau yeej ntawm tus nqi tag nrho. Rau ntev mus txog lossis 400G / 800G cov phiaj xwm, ib hom yog lub hauv paus zoo.

Xaus

Qhov kev txiav txim siab OM3 vs OM4 nqis los rau plaub lub levers: yuav tsum tau ceev, txuas nrug, txuas thiab poob nyiaj txiag, thiab ntev npaum li cas cov cable yuav nyob hauv qhov chaw. OM3 khaws cov nqi qis rau luv luv 10G txuas thiab cov nroj tsuag uas twb muaj lawm. OM4 muab koj qhov ncav cuag thiab cov npoo uas xav tau rau 25G, 40G, thiab 100G luv- mus txog cov tes hauj lwm, thiab nws tau dhau los ua qhov kev xaiv zoo tshaj plaws rau cov ntaub ntawv txuas tshiab. Rau cov kev sib txuas uas tshaj multimode qhov kev ncua deb, tsis yog OM3 lossis OM4 yog cov lus teb yog - uas yog qhov twgtib - hom fiber ntaunyob.

Ua ntej koj yuav, paub meej tias qhov kev txhawb nqa ncav cuag qhov tseeb ntawm cov ntaub ntawv transceiver, xam qhov kev poob qis nrog rau txhua qhov txuas thiab splice, thiab tsim qhov txuas nrog tsawg kawg 1 dB ntawm lub taub hau. Xaiv cov kab hluav taws xob ib leeg, yam tsis tau kuaj xyuas qhov txuas ntxiv, yog qhov laj thawj feem ntau vim li cas cov nroj tsuag fiber ntau ua tsis tiav nws thawj hnub ntawm kev sim.

 

Xa kev nug