Yog koj muab pivMPO vs MTP connectors, thawj qhov yuav tsum nkag siab yog tias lawv tsis yog ob tsev neeg sib txuas. MPO piav qhia txog tus txheej txheem ntau-fiber connector interface, thaum MTP® yog US Conec lub npe, tsim qauv siv MPO hom.
Qhov kev sib txawv ntawd hloov qhov kev txiav txim siab yuav khoom. Cov lus nug tswv yim tsis yog seb lo lus "MTP" puas zoo dua li "MPO." Nws yog seb lub cable sib txuas nrog cov khoom siv sib txuas, suav fiber ntau, keying, pinned lossis unpinned configuration, polarity, fiber ntau, kawg -fab geometry, thiab optical poob nyiaj-thiab seb puas muaj MTP- tshwj xeeb feature ua pov thawj nws cov nqi.
Koj Yuav Tsum Xaiv MPO lossis MTP?
- Xaiv MTP tiagThaum cov khoom siv, cov neeg siv khoom tshwj xeeb, daim ntawv teev npe tsim nyog, lossis cov ntaub ntawv ua haujlwm qhia meej yuav tsum muaj MTP cov khoom.
- Lub rooj sib tham MPO tsim nyog yuav txausthaum nws phim tus qauv tsim nyog interface thiab ua tau raws li qhov project qhov ntxig - poob, rov qab los - poob, txhua yam, ib puag ncig, thiab lub neej yuav tsum tau ua.
- Tsis txhob xaiv los ntawm Ethernet ceev ib leeg.400G thiab 800G optics tuaj yeem siv cov khoom sib txuas sib txawv, suav nrog MPO-12, MPO-16, dual MPO-12, thiab duplex LC.
- Tsis txhob sib piv cov ntawv cim npe tsis yog cov lus qhia tshwj xeeb.Sib piv cov kev ua tau zoo ntawm kev ua tiav cable sib dhos uas koj tab tom yuav tiag tiag.
Rau kev sib txuas lus txuas thiab cov qauv, saib qhov nofiber optic connector hom qhia.

MPO vs MTP: Qhov txawv tseem ceeb ntawm ib saib
| Qhov xwm txheej | MPO | MTP® |
|---|---|---|
| Nws yog dab tsi | Ib tug standardized multi{0}}fiber connector tsev neeg/interface | Lub US Conec hom ntawm MPO connector |
| Cov qauv kev sib raug zoo | Txhais los ntawm MPO interface qauv | Tsim los ua raws li MPO interface cov qauv |
| Intermateability | Nyob ntawm qhov sib piv cov qauv kev sib txuas, fiber ntau- suav tsev neeg, keying, thiab poj niam txiv neej | tuaj yeem cuam tshuam nrog cov qauv sib xws- ua raws MPO interfaces |
| Kev tsim kho tshuab | Nws txawv ntawm cov chaw tsim khoom thiab cov khoom | suav nrog US Conec tsim cov yam ntxwv xws li ferrule ntab thiab tswj cov lus qhia -pin geometry |
| Optical kev ua tau zoo | Nws txawv los ntawm cov chaw tsim khoom, qib ferrule, polishing, txiav, thiab kev xeem specification | Muaj nyob rau hauv MTP cov qhab nia ua tau zoo; qhov tseeb los ua ke specification tseem tseem ceeb |
| Polarity | Nyob ntawm cov kab ke architecture | Nyob ntawm cov kab ke architecture; Qee cov khoom lag luam MTP ntxiv kev teeb tsa thaj chaw |
| Nqi | Broad kev muag khoom thiab kev ua haujlwm ntau | Feem ntau nqa cov khoom lag luam / cov khoom them nqi uas yuav tsum tau ua raws li qhov xav tau ntawm qhov project |
| Txoj kev yuav khoom zoo tshaj plaws | Qhia kom meej qhov kev sib dhos ua tiav thiab xyuas qhov kev ua tau zoo | Qhia meej MTP tiag tiag tsuas yog thaum nws lub hom phiaj, kev ua tau zoo, kev pabcuam, lossis kev tsim nyog tus nqi yog yuav tsum tau |
MPO Connector yog dab tsi?
MPO sawv rauMulti-Fiber Push-On. Nws yog ib tug multi-fiber optical connector tsev neeg siv nyob rau hauv siab - ntom qauv cabling, parallel-optics links, pob tw, cassettes, breakout assemblies, thiab ncaj qha cov khoom sib txuas. CovIEC 61754-7-1 tus qauv, piv txwv li, txhais qhov ntev interface rau ib - kab MPO connector variants.
Ib qho MPO ferrule aligns ntau fibers tib lub sijhawm, uas ua rau cov hom ntawv muaj txiaj ntsig zoo nyob qhov twg qhov ceev thiab teeb meem kev teeb tsa. Cov ntawv thov feem ntau suav nrog cov ntaub ntawv-cov pob txha caj qaum hauv nruab nrab, cov tshuab kaw lus, cov kab sib txuas sib txuas sib txuas, sib txuas ib leeg- hom kev sib txuas, thiab siab - qhov sib txuas ntawm qhov sib txuas.
Txawm li cas los xij, "MPO" los ntawm nws tus kheej tsis yog qhov ua tiav cable specification. MPO cov rooj sib tham tuaj yeem sib txawv ntawm fiber ntau suav, keying, poj niam los txiv neej, polarity, fiber ntau, kawg -fab geometry, cable tsim, thiab kev ua haujlwm kho qhov muag. Yog tias koj tab tom ntsuas cov qauv sib dhos muaj, pib nrog qhov dav duaMPO / MTP fiber ntau optic cable tsev neegthiab ces nqaim lub configuration rau cov khoom yuav tsum tau.
MPO-12 thiab MPO-16 tsis yog tib lub interface
Ib txwm siv MPO systems feem ntau siv ib qho -kab 12- txoj hauj lwm ferrules, txawm hais tias 8 active fibers yuav siv tau nyob rau hauv ntau daim ntawv thov parallel-optics. Cov tshuab tshiab tuaj yeem siv 16-fiber MPO interfaces.
MPO-16 interface tsis tsuas yog MPO-12 connector nrog plaub fiber ntau. Nws siv txawv keying. US Conec's MTP-16 cov ntaub ntawv khoom lag luam txheeb xyuasoffset keying thiab ua raws li MPO-16 interface qauv. Qhov no yog vim li cas qhov kev thov yuav khoom uas hais tias tsuas yog "MPO cable" tsis txaus thaum cov khoom siv nquag yuav tsum muaj qhov tshwj xeeb MPO-16 interface.

MTP Connector yog dab tsi?
MTP® yog lub npe US Conec hom ntawm MPO connector.US Conec piav txog nwsMTP connector portfolioraws li MPO- hom kev daws teeb meem uas suav nrog patented mechanical features, enhanced precision, and defined performance options.
Cov chaw tsim khoom cov ntaub ntawv piav qhia txog cov yam ntxwv xws li lub ferrule ntab, nruj tswj elliptical phau ntawv qhia- cov lus qhia tus pin, lub hlau pin clamp, lub caij nplooj ntoos hlav geometry npaj los muab cov fiber ntau-ribbon clearance, thiab tshem tau vaj tse nyob rau hauv kev teeb tsa. Cov no yog cov khoom tiag tiag- tsim qhov sib txawv, tab sis lawv tsis pom zoo rau kev kho txhua yam tsis yog -MTP MPO connector raws li ib qho qis dua - qeb ua haujlwm.
MPO cov khoom sib txawv heev los ntawm tus neeg muag khoom, ferrule zoo, txheej txheem txiav, polishing, xeem txoj kev, tswj txheej txheem, thiab lav tsis tau. Qhov kev sib piv raug yog vim li no ntawm cov khoom tsim nyog, tsis yog ntawm ob daim ntawv lo hauv kev sib cais.
Puas yog MTP tib yam li MPO?
Tsis raws nraim. Ib qho txiaj ntsig shorthand yog:
MTP yog MPO connector platform, tab sis MPO yog qhov dav dua cov qauv sib txuas.
US Conec xeev hauv nwsMTP technical FAQtias MTP connectors ua raws li MPO connector qauv thiab yog intermateable nrog coj raws li MPO connectors-style connectors.

Puas yog MPO thiab MTP Connectors Compatible?
Lawv tuaj yeem yog, thaum cov interfaces tiag tiag sib phim.Kev sib cuam tshuam ntawm lub cev tsis txhais tau tias MPO lossis MTP cable tuaj yeem txuas nrog lwm tus MPO-style interface yam tsis tau kuaj xyuas tus qauv tsim.
Ua ntej mating los yog xaj ib lub rooj sib txoos, xyuas cov hauv qab no:
- fiber ntau- suav tsev neeg, xws li MPO-12-tsev neeg lossis MPO-16;
- keying thiab key orientation;
- pinned los yog unpinned configuration;
- polarity thiab kab qhia kev;
- multimode los yog ib zaug - hom fiber ntau;
- UPC lossis APC kawg -fim qhov yuav tsum tau muaj;
- qhov siab tshaj plaws tso cai nkag poob thiab rov qab los - qhov yuav tsum tau poob.
Pinned vs Unpinned: Poj niam los txiv neej yuav tsum phim qhov txuas tsim
MPO- tsev neeg txuas siv cov lus qhia pins los ua kom cov MT ferrules. Ib tug pinned connector feem ntau hu uatxiv neej, thaum lub unpinned connector feem ntau hu uapoj niam. Ib qho kev sib txuas sib txuas yuav tsum muaj qhov tseeb pinned / unpinned kev sib raug zoo.
Tsis txhob xav tias txhua tus transceiver lossis lub cev siv tib yam poj niam txiv neej. Cov ntaub ntawv khoom siv yuav tsum tswj kev xaiv. Piv txwv li, Cisco cov ntaub ntawv tam sim no 800G OSFP qhia pinned MPO chaw nres nkoj rau MPO- cov modules uas tau teev nyob rau ntawd thiab yog li yuav tsum tau unpinned cable connectors ntawm cov chaw nres nkoj.
Polarity yog qhov teeb meem tsim channel
Polarity txiav txim seb yuav kis tau li cas thiab tau txais daim ntawv qhia txoj kab los ntawm kev ua tiav cov kab ke. Hom A, Hom B, thiab Hom C feem ntau sib tham hauv cov qauv cabling, tab sis kev siv kom raug yog nyob ntawm adapters, cassettes, trunks, harnesses, thiab active khoom.
Ib qho MTP cable uas tsis ncaj ncees lawm polarity tseem yog qhov tsis ncaj ncees lawm cable. MTP tsis muaj tus qauv polarity cais. Txawm li cas los xij, qee cov khoom lag luam ntxiv cov kev pabcuam zoo. CovMTP PRO connector, piv txwv li, txhawb kev txhais tus pin thiab polarity reconfiguration.

Puas yog MTP Ib txwm muaj qhov poob qis dua li MPO?
Tsis muaj txoj cai thoob ntiaj teb txhawb qhov kev txiav txim siab vimMPO tsis yog ib qho kev kho qhov muag - qib kev ua tau zoo. Ob lub rooj sib tham MPO los ntawm cov chaw muag khoom sib txawv tuaj yeem muaj qhov sib txawv ntawm ferrule kam rau ua, polishing zoo, ntxig- tsis lees paub, xa rov qab- poob kev ua tau zoo, kev tsim khoom, thiab cov kev sim.
Rau kev tsim channel, sib piv:
- qhov siab tshaj plaws tau lees paub qhov poob rau kev sib dhos ua tiav;
- rov qab poob qhov twg daim ntawv thov ua rau nws cuam tshuam;
- xeem wavelength thiab xeem txoj kev;
- random- kev sib tw los yog kev siv - sib piv cov kev xav, yog hais;
- Environmental thiab lifecycle kev tsim nyog;
- cov ntaub ntawv xeem tiag tiag rau cov rooj sib txoos muab.
Yog tias koj xav tau ib qho refresher li cas connector, splice, thiab fiber attenuation accumulate, saib phau ntawv qhia nokev poob qis hauv fiber ntau.
Vim li cas qhov Link Budget tseem ceeb dua li lub npe txuas
Txhua lub ntsiab lus passive siv ib feem ntawm qhov kho qhov muag channel qhov tso cai poob. High-cov ntawv thov multimode ceev tuaj yeem tawm me ntsis rau cov khoom sib txuas thiab cov cassette. Raws li ib qho piv txwv luam tawm,Fluke Networks teev 40GBASE-SR4 poob txwv ntawm 1.9 dB rau OM3 thiab 1.5 dB rau OM4hauv nws cov lus qhia MultiFiber Pro.
Cov nuj nqis no yog daim ntawv thov -channel txwv, tsis yog MPO connector specifications. Yog tias ob qhov tsim nyog cable sib dhos ob qho tib si haum rau hauv qhov project qhov poob peev nyiaj nrog cov npoo txaus, yam xws li kev muaj, kev pabcuam, kev pom zoo- tus neeg muag khoom, kev xav tau ntawm lub neej, thiab tus nqi yuav tseem ceeb dua li cov khoom sib txuas.
MPO vs MTP Tus Nqi: Thaum twg MTP Hwm Tsim Nyog Nws?
MTP cov rooj sib txoos feem ntau raug nqi ntau dua li cov khoom siv MPO ntau dua vim tias MTP lub npe txheeb xyuas cov txheej txheem tshwj xeeb nrog cov qauv tsim, qib kev ua tau zoo, kev tsim khoom, thiab daim ntawv tso cai / tus nqi lag luam. Tus nqi tiag tiag txawv ntawm kev teeb tsa thiab tus neeg muag khoom, yog li qhov feem pua taag tsis muaj txiaj ntsig rau kev txiav txim siab engineering.
Tus nqi them tau yooj yim dua los ua pov thawj thaum ib lossis ntau dua ntawm cov xwm txheej no siv:
- tus neeg siv khoom, OEM, lossis qhov project specification qhia meej yuav tsum muaj cov khoom MTP tiag;
- ib qho kev xaiv MTP qib kev ua tau zoo muab qhov kev lav phib xaub uas xav tau rau qhov txuas;
- teb polarity los yog pin configurability txo cov khoom seem los yog rework;
- rov mating, tu, los yog reconfiguration yuav tsum;
- lub koom haum muaj cov txheej txheem tsim nyog thiab kev saib xyuas cov txheej txheem nyob ib ncig ntawm MTP cov khoom;
- cov txheej txheem tivthaiv txo cov kev pheej hmoo ua haujlwm txaus los pab txhawb tus nqi BOM ntau dua.
Ib tus qauv- ua raws MPO sib dhos tuaj yeem yog qhov kev xaiv ua lag luam zoo dua thaum nws ua tau raws li qhov sib txuas, kho qhov muag, ib puag ncig, thiab kev ua neej nyob yam tsis tau ntxiv cov yam ntxwv ntawm qhov project yuav tsis siv.
Sib piv Tus Nqi Tag Nrho, Tsis yog Tus Nqi Cable xwb
Rau qhov kev sib piv ncaj ncees, suav nrog tus nqi pib ua ke nrog rau kev sim, ntawv pov thawj, khoom seem, kev tsim kho dua tshiab, kev pheej hmoo ntawm kev hloov pauv, lub sijhawm ua haujlwm, thiab kev pom zoo - tus neeg muag khoom yuav tsum tau ua. Ib tug pheej yig dua cable uas ua rau polarity rework los yog ua tsis tau cov nyiaj txiag poob tsis yog tiag tiag pheej yig dua. Ib yam li ntawd, them tus nqi them rau cov khoom lag luam uas qhov txuas tsis xav tau tsuas yog nce BOM nqi.
MPO vs MTP rau 40G, 100G, 400G, thiab 800G
Ethernet ceev tsis txawv txav ntawm qhov txuas. Lub transceiver's optical architecture ua.
Qhov no yuav pom tseeb ntawm 400G. Cisco cov400G QSFP-DD transceiver data sheetcov npe, ntawm lwm yam piv txwv:
- QDD-400G-SR8-S nrog MPO-16 APC multimode interface;
- QDD-400G-SR4.2-BD nrog MPO-12 UPC multimode interface;
- QDD-400G-DR4-S nrog MPO-12 APC ib hom interface;
- QDD-400G-FR4-S nrog duplex LC ib hom interface.
Tib txoj cai siv ntawm 800G. Cisco cov800G OSFP transceiver data sheetsuav nrog cov qauv siv dual MPO-12 APC, MPO-16 APC, thiab dual duplex LC interfaces.
Yog li "Kuv xav tau 800G cable" tsis yog qhov ua tau zoo cable specification. Koj xav tau qhov tseeb optic ib feem naj npawb thiab interface. Rau cov ntsiab lus dav dav ntawm module, qhov noQSFP-DD technical overviewtuaj yeem pab txuas kev xaiv transceiver nrog cov kev xav tau ntawm cable.

Yuav Ua Li Cas Xaiv Ntawm MPO thiab MTP
Kauj Ruam 1: Txheeb xyuas cov khoom siv tiag tiag
Pib nrog lub transceiver, hloov, thaj vaj huam sib luag, cassette, lossis cov ntaub ntawv ntaus ntawv. Sau tus naj npawb ib feem thiab connector interface. Txiav txim siab seb qhov chaw nres nkoj xav tau ib txwm siv MPO-tsev neeg interface, MPO-16, duplex LC, lossis lwm qhov txuas.
Kauj ruam 2: Paub meej tias Fiber Hom thiab Active Fiber suav
Txheeb xyuas seb daim ntawv thov siv ntau hom lossis ib zaug - hom fiber ntau thiab pes tsawg fibers ua haujlwm tiag tiag. MPO ferrule tej zaum yuav muaj ntau txoj haujlwm tshaj qhov kev siv kho qhov muag.
Kauj Ruam 3: Txheeb xyuas Keying, Poj Niam Txiv Neej, Polarity, thiab Xaus -Lub ntsej muag Geometry
Document qhov tseem ceeb orientation, pinned/unpinned txheej xwm ntawm ob hnub kawg, kawg - mus rau -kawg polarity, adapter orientation, breakout mapping, thiab UPC/APC yuav tsum tau. Cov kev txwv no txiav txim siab seb lub rooj sib txoos puas tuaj yeem ua haujlwm ntawm lub cev thiab optically ua haujlwm hauv cov channel npaj.
Kauj ruam 4: Xam cov nyiaj poob
Ntxiv qhov kev xav tau poob los ntawm fiber ntau attenuation, txhua tus khub txuas txuas, cassettes lossis modules, splices, thiab lwm yam khoom siv passive. Sib piv tag nrho nrog rau qhov siab tshaj plaws channel poob tso cai los ntawm daim ntawv thov kho qhov muag thiab tawm hauv qhov kev ua haujlwm zoo.
Kauj Ruam 5: Sib piv Cov Lus Qhia Txog Kev Ua Ua Ntej
Thov qhov siab tshaj plaws tau lees paub qhov poob, rov qab poob qhov twg muaj feem xyuam, xeem txoj hauv kev, cov ntaub ntawv tsim nyog, thiab cov ntaub ntawv xeem ntau lawm. Yog tias qhov qis dua - qhab nia MTP yuav tsum tau ua kom tau raws li cov peev nyiaj hauv channel, qhia nws. Yog tias lub rooj sib tham MPO tsim nyog muab cov paj laum txaus, MTP hom yuav tsis tsim nyog.
Kauj Ruam 6: Xav txog kev ua haujlwm thiab lub neej voj voog
Xav tshaj thawj qhov kev teeb tsa. Puas yuav txuas ntxiv mus ntxiv? Lub xaib puas xav tau kev hloov pauv polarity? Puas yog tib lub platform txuas siv thoob plaws ntau qhov chaw? Puas yog cov khoom seem thiab kev cob qhia kws tshaj lij?
US Conec tau hais hauv nws cov MTP FAQ tias, nyob rau hauv kev siv ib txwm siv thiab kev tu kom zoo, MTP connectors tuaj yeem muaj sia nyob zoo dua 1,000 tus khub / demate cycles. Kho qhov ntawd raws li cov chaw tsim khoom lag luam- cov lus qhia txog kev ruaj ntseg es tsis yog kev thov txog txhua yam khoom MPO.
Kauj Ruam 7: Xaiv qhov Kev Tsim Kho Cable
Qhov kev txiav txim siab txuas tsuas yog ib feem ntawm kev sib dhos. Ib qhov project yuav xav tau ib txoj hlua khi, lub cev, hlua, lossis kev sib tsoo cable. Rau cov tswv yim sib txawv ntawm cov qauv no, saib covMPO cable hom thiab cov lus qhia xaiv.
Rau qaum thiab ntoo khaub lig- txuas tsim,MPO / MTP lub cev cablesfeem ntau yog siv los nqa ntau cov fibers ntawm cov vaj huam sib luag lossis cov khoom siv. Qhov twg cov kab sib txuas yuav tsum ntxuam tawm mus rau ib tus neeg duplex lossis simplex interfaces, ib qhoMPO / MTP breakout cabletej zaum yuav tsim nyog dua.
Feem ntau MPO/MTP Kev Yuav Tsis Txaus
Ordering los ntawm Connector Name Ib leeg
"12-fiber MTP cable, 10 meters" tseem tsis tiav. Nws tsis txhais cov polarity, poj niam txiv neej, kev taw qhia tseem ceeb, hom fiber ntau, qhov kawg ntawm lub ntsej muag geometry, poob qib, qhov ntsuas lub tsho, lossis cov khoom sib txuas uas yuav tsum muaj nyob rau qhov kawg.
Tsis meej pem MPO-12 thiab MPO-16
Lawv yog cov tsev neeg sib txawv interface nrog sib txawv keying. Paub meej tias lub transceiver interface ua ntej xaj lossis rov siv dua cov cabling.
Piv txwv tias txhua MPO muaj qhov ua tau zoo ib yam
MPO yog qeb interface, tsis yog kev nkag mus thoob ntiaj teb - qib poob. Siv tus neeg muag khoom tau lees paub qhov txiaj ntsig siab tshaj plaws thiab cov ntaub ntawv xeem.
Kev Tsim Kho Nrog Cov Qauv Hloov Tsis Txaus Siab Tshaj
Qhov kev ua tau zoo piav qhia txog yam khoom uas feem ntau ua tiav. Qhov phem tshaj - rooj plaub channel tsim yuav tsum siv cov kev txwv tsim nyog tshwj tsis yog tias txoj kev tsim vaj tsev tau tso cai rau lwm yam.
Tsis quav ntsej tshuaj xyuas thiab ntxuav
Ntau -fiber ferrules nthuav tawm ntau qhov kev sib txuas kho qhov muag hauv ib qho txuas, yog li kev sib kis tuaj yeem cuam tshuam rau ntau txoj kab hauv ib zaug. Fluke Networks cov lus qhia rauntxuav thiab tshuaj xyuas MPO / MTP connectorspom zoo kom ntxuav ua ntej kev sib txuas thiab tshuaj xyuas kom paub tseeb qhov tshwm sim. Siv cov cuab yeej thiab cov lus qhia sojntsuam tsim los rau ntau- fiber ntau connectors.
Illustraative Procurement Scenario
Xav txog ib pab neeg xaj kom hloov qhov txuas los ntawm daim ntawv yuav khoom uas hais tias tsuas yog "12-fiber MTP cable." Lub cable tuaj txog nrog qhov tseeb fiber ntau suav thiab connector hom tab sis tsis ncaj ncees lawm pinned / unpinned configuration rau lub transceiver ports. Cov connectors tsis tuaj yeem tsim cov khub niam txiv, yog li kev teeb tsa nres txawm tias cov lus piav qhia ntawm cov khoom tau saib qhov tseeb.
Qhov kho yog tsis qhia kom meej tus nqi kim dua connector. Qhov kev txhim kho yog txhawm rau txheeb xyuas qhov txuas ua tiav: interface ntawm txhua qhov kawg, suav fiber ntau, poj niam txiv neej, keying, polarity, fiber ntau, kawg - ntsej muag geometry, ntev, cable siv, thiab kev ua haujlwm kho qhov muag.
FAQ
Puas yog MTP tib yam li MPO?
Tsis yog. MPO yog tus qauv txuas rau tsev neeg. MTP® yog US Conec's branded MPO connector platform. MTP haum nyob rau hauv lub dav MPO qeb.
Puas yog MTP Connector Plug rau hauv MPO Connector?
Cov qauv sib xws-raws li MTP thiab MPO interfaces tuaj yeem sib cuam tshuam, tab sis fiber ntau- suav tsev neeg, keying, pinned/unpinned configuration, polarity, fiber ntau, thiab optical xav tau tseem yuav tsum sib phim.
Puas yog MTP Ib txwm zoo dua MPO?
Tsis yog rau txhua qhov project. MTP suav nrog cov txheej txheem engineering thiab kev xaiv ua haujlwm, tab sis kev tsim nyog MPO tuaj yeem tsim nyog thaum nws ua tau raws li txhua qhov kev sib tshuam, kho qhov muag, tshuab, ib puag ncig, thiab kev ua neej nyob.
Puas yog MTP kim dua MPO?
Nws feem ntau nqa tus nqi vim tias MTP txheeb xyuas cov npe tshwj xeeb ntawm lub platform thiab kev ua haujlwm ecosystem. Cov lus nug cuam tshuam yog seb tus nqi them puas yuav qhov kev xav tau uas qhov project xav tau tiag tiag, xws li qib kev ua haujlwm tau teev tseg, kev teeb tsa hauv cheeb tsam, kev tsim qauv, lossis kev pom zoo- cov xwm txheej.
Puas yog MTP Yuav Tsum Tau rau 400G lossis 800G?
Tsis yog . 400G thiab 800G tsis yog txiav txim siab qhov sib txuas. Nyob ntawm lub transceiver, lub interface tej zaum yuav yog MPO-12, MPO-16, dual MPO-12, duplex LC, los yog lwm hom. Nco ntsoov xyuas daim ntawv qhia tseeb module.
Qhov txawv ntawm MPO-12 thiab MPO-16 yog dab tsi?
Lawv muaj qhov sib txawv fiber ntau -txoj hauj lwm npaj thiab sib txawv tus qauv keying. Tsis txhob hloov ib qho rau lwm qhov tshwj tsis yog tias tus qauv cabling txhob txwm muaj xws li kev hloov dua siab tshiab lossis kev sib dhos sib dhos.
Puas yog MPO thiab MTP Connectors xav tau kev tu tshwj xeeb?
Lawv xav tau kev ntxuav thiab tshuaj xyuas kom haum rau ntau- fiber ntau ferrules. Siv cov cuab yeej siv tshuaj ntxuav thiab tshuaj xyuas, thiab xyuas lub ntsej muag kawg ua ntej sib yuav.
Thaum kawg Takeaway: Qhia qhov txuas, Tsis yog daim ntawv lo xwb
Qhov tseem ceeb tshaj plaws los xav txogMPO vs MTP connectorstsis yog "standard connector piv rau zoo connector." MPO yog cov qauv sib txuas dav dav rau tsev neeg; MTP yog ib qho kev tsim kho MPO platform nrog cov ntaub ntawv tsim thiab kev xaiv ua haujlwm.
Rau lub network tiag tiag, pib nrog cov khoom siv interface. Tom qab ntawd txhais cov suav fiber ntau, keying, pinned/unpinned configuration, polarity, fiber type, kawg-fab geometry, poob nyiaj txiag, cable tsim, kuaj, thiab lifecycle yuav tsum. Tsuas yog tom qab cov kev hloov pauv no tau pom tseeb yog tias koj txiav txim siab seb lub rooj sib tham MPO tsim nyog puas txaus lossis puas yog MTP tiag muab tus nqi uas tsim nyog rau qhov yuav tsum tau ua ntxiv.
Xaiv lub interface ua ntej, txhais cov kev ua haujlwm thib ob, thiab xaiv cov khoom thib peb.