Blockless PLC Splitter

Xa kev nug
Blockless PLC Splitter
Paub meej
DIMI 1 × 2 Blockless PLC Fiber Splitter sawv cev rau qhov kev hloov pauv tseem ceeb hauv daim ntawv thiab xa mus yooj yim. Los ntawm kev tshem tawm cov tsoos hlau los yog ABS lub thawv ntim khoom, qhov kev tsim qauv mini no txo ​​qhov loj me rau 4 × 60 × 7 hli - me me kom haum ncaj qha rau hauv cov tais diav, fiber ntau tswj vaj huam sib luag, lossis cov rooj sib tham hauv txoj kev tsis tas yuav tsum tau kho vajtse ntxiv.
Cov hneev taw me me yog ua ke nrog G.657A1 khoov-insensitive singlemode fiber ntau pigtails thiab Hoobkas- polished SC/APC connectors, ua kom ntsaws- thiab -play installation nrog xoom teb splicing rau sab connector thiab ib zaug - fusion npaj rau cov tswv yim pub. Qhov kev tsim no zoo tagnrho rau cov neeg ua haujlwm nrhiav kom nrawm nrawm nrawm, txo qis kev ua haujlwm, thiab txo cov ntsiab lus tsis ua haujlwm hauv cov thawv ntim sab nraum zoov, cov chaw sib sau hauv pem teb, lossis cov khoom siv hauv chav patching.
Qhov Zoo Tshaj Plaws
70% poob phaus piv rau cov tsoos splitters
Zero teb splicing yuav tsum tau rau connector sab
100% Hoobkas kuaj xyuas kom ntseeg tau
Tau tshaj txhua tus qauv PON loj
Txo lub sij hawm installation txog li 50%
Kev faib tawm yam khoom
PLC Splitter
Share to
Hauj lwm lawm

 

Yooj yim Customization rau koj qhov project

Split Ratios

Muaj nyob rau hauv 1 × 2, 1 × 4, 1 × 8, 1 × 16, 1 × 32, 1 × 64, nrog rau cov kev teeb tsa sib npaug xws li 2 × 2, 2 × 4, 2 × 8, 2 × 16, 2 × 32, 2 × 64 rau ntau- theem kev faib cov qauv.

 

Hom Connector

SC/APC (tus qauv), SC/UPC, LC/APC, LC/UPC, los yog sib xyaw connector configurations kom phim headend khoom, ONT pab kiag li lawm, thiab uas twb muaj lawm infrastructure - los yog qhia "tsis muaj connector" rau fusion splicing nyob rau hauv kaw enclosures.

 

Hom fiber ntau

LG.657A1 (standard), G.657A2 (tighter bend radius for ultra-compact spaces), los yog G.652D for legacy compatibility, all ntsib ITU-T specifications.

 

Input/Output Fiber Length

Kho los ntawm 0.5m mus rau 3m los yog qhia kom meej cov kev cai ntev kom tshem tawm ntau coiling nyob rau hauv txee los yog muab ntxiv cuag rau txoj kev nyuaj routing.

 

Fiber Diameter Options

Xaiv 0.9mm nruj-buffer rau sab hauv tsev patch qaum style, 2.0mm rau ruggedized sab nraum zoov pigtails, los yog 3.0mm rau armored tiv thaiv nyob rau hauv hnyav ib puag ncig.

 

Labeling & Port Identification

Kev cai chaw nres nkoj naj npawb, cov ntawv sau ua ntu zus (xws li "Chaw nres nkoj 1 ntawm 32"), xim -coded ob txhais ceg rau kev txheeb xyuas qhov nrawm nrawm, thiab cov lej lej sib piv nrog koj cov ntaub ntawv network.

 

Package Form Factor

Tshaj li mini module, peb muab cov fiber ntau liab qab (rau kev sib txuas ncaj qha), compact ABS box type, LGX cassette (19 "rack compatible), siab -cov cassettes ceev rau ODF/FDB kev koom ua ke, thiab 1U/2U khib-mount chassis nrog swb- tawm tais.

 

OEM / ODM Branding

Siv koj lub tuam txhab lub logo, cov lej feem, QR cov lej, thiab cov ntawv ntim kev cai - zoo tagnrho rau cov neeg sib koom ua ke, tus kheej - cov neeg faib khoom, thiab cov neeg cog lus ua haujlwm rau ntau tus neeg siv khoom.

 

Cov ncauj lus qhia ntxaws ntxaws

Parameter Tus nqi Chav tsev Sau ntawv
Split Ratio 1×2 - Symmetrical
Insertion Loss Tsawg dua lossis sib npaug rau 4.1 dB 1310/1490/1550 nm
Kev tsis sib xws Tsawg dua los yog sib npaug li 0.4 dB Nruab nrab ntawm cov chaw tso zis
Rov Los Los Ntau dua lossis sib npaug li 55 dB SC / APC connectors
PDL Tsawg dua los yog sib npaug li 0.2 dB Polarization- nyob ntawm qhov poob
WDL Tsawg dua los yog sib npaug li 0.3 dB Wavelength - nyob ntawm qhov poob
TDL Tsawg dua los yog sib npaug li 0.5 dB Kub- nyob ntawm qhov poob
Kev taw qhia Ntau dua lossis sib npaug li 55 dB Kev rho tawm ntawm cov chaw nres nkoj
Ua haujlwm Wavelength 1260-1650 nm Tag nrho PON spectrum
Ua haujlwm kub -40 rau +85 degree Tag nrho - huab cua ua haujlwm
Cia Kub -40 rau +85 degree Extended kub ntau yam
Cov av noo 0-95 % Tsis yog -condensing
Hom Fiber G.657A1 - Khoov-sensitive singlemode
Fiber suav 1 input, 2 outputs - 900μm nruj -buffer
Hom Connector SC/APC - Factory-tso tseg
Qhov ntev 4×60×7 mm Blockless mini module
Qhov hnyav Tsawg dua los yog sib npaug li 5 g Tsis suav nrog fiber ntau pigtails
Ua raws ITU-T G.657A1, Telcordia GR-1209, GR-1221 - Telecom qauv

Nta

Blockless Mini Module Architecture

Kev tshem tawm cov hlau tsis nruj los yog cov yas yas txo qhov hnyav ntau dua 70% piv rau cov tsoos ABS lub thawv cais, ua qhov qauv no zoo tagnrho rau qhov chaw - txwv ib puag ncig xws li ncej- mounted splice kaw, hauv av vaults, thiab siab - ntom fiber ntau tswj vaj huam sib luag.

 

Lub nti PLC raug kaw yog hermetically kaw thiab mechanically reinforced nrog tsis muaj kev tiv thaiv, kom ruaj khov tsis muaj tej. Cov neeg ua haujlwm txhim kho tuaj yeem ua haujlwm thiab ruaj ntseg ntawm lub module hauv vib nas this siv cov hlua khi lossis cov tais uas twb muaj lawm, ua kom cov sijhawm ua haujlwm nrawm thiab txo cov nqi khoom siv.

Ultra-Low Insertion Loss Tsawg dua lossis sib npaug rau 4.1 dB

Kev ua tiav qhov poob qis hauv qab 4.1 dB ntawm 1310/1490/1550 nm wavelengths ua kom muaj peev xwm muaj peev xwm siv tau rau kev xa hluav taws xob qis, txhais ncaj qha mus rau qhov ntev fiber ntau, sib faib ntau dua hauv cascaded architectures, lossis cov kab ke ntxiv rau kev hloov kho tshiab rau yav tom ntej.

 

Rau cov tswv lag luam npaj 20 km+ feeder khiav los yog siv XGS-PON nrog cov peev nyiaj siv zog nruj dua, txhua feem kaum ntawm dB teeb meem - qhov splitter no khaws cia qhov tseem ceeb hauv lub taub hau thaum tswj kev tsim khoom sib xws ntawm cov khoom tsim tawm.

Superior Uniformity Tsawg dua lossis sib npaug rau 0.4 dB

Uniformity ntsuas qhov siab tshaj plaws lub zog sib txawv ntawm cov chaw nres nkoj tso zis. Tsawg dua lossis sib npaug li 0.4 dB, qhov kev faib tawm no ua kom ob qho kev tawm tau txais yuav luag zoo tib yam lub teeb liab lub zog, tshem tawm cov chaw nres nkoj "kub" thiab "txias" uas tuaj yeem ua rau mob taub hau lossis kev pabcuam degradation.

 

Rau cov phiaj xwm network, qhov no txhais tau hais tias kev sib txuas yooj yim ntawm kev suav nyiaj txiag, kev ua tau zoo ntawm cov neeg siv khoom xav tau, thiab txo qhov xav tau rau ib -chaw nres nkoj them nyiaj lossis optical amplifiers. Uniformity no nruj yog tshwj xeeb tshaj yog muaj nqis nyob rau hauv POL deployments qhov twg pua pua ntawm cov ntsiab lus kawg yuav tsum xa cov neeg siv kev paub zoo ib yam.

G.657A1 Khoov-Insensitive Fiber

G.657A1 fiber ntau ua tau raws li ITU-T specifications rau txo macro- khoov poob, tolerating khoov radii kom nruj li 10 hli nrog negligible attenuation nce. Qhov no tso cai rau kev teeb tsa pab pawg kom xa cov pigtails los ntawm txoj hauv kev congested, qhwv ntev ntev hauv cov voj voog loj, thiab taug kev nyob ib puag ncig yam tsis muaj kev txhawj xeeb txog teeb meem degradation.

 

Hauv cov txee sab nraum zoov uas muaj kev sib tw ua kom sov thiab kev co, khoov- fiber ntau tswj kev ua haujlwm ruaj khov txawm tias fiber ntau tswj cov tais hloov los yog nyob rau lub sijhawm. Lub 900μm nruj- txheej tsis yog muab kev tiv thaiv cov neeg kho tshuab ntxiv thiab yooj yim ntawm kev tuav thaum fusion splicing.

Factory-Terminated SC/APC Connectors

Txhua qhov tso zis pigtail yog Hoobkas- txiav nrog SC/APC connectors, featuring 8-degree angled lub cev tiv tauj uas xa ntau dua los yog sib npaug rau 55 dB rov qab poob - tseem ceeb rau txo qis rov qab{5}} kev xav uas tuaj yeem degrade burst-mode upstream. kis tau tus mob hauv P.

 

Ua ntej- polished connector kawg- lub ntsej muag raug tshuaj xyuas nyob rau hauv lub tshuab kuaj kab mob thiab interferometer kom ntseeg tau tias IEC-raws li geometry, tshem tawm thaj chaw polishing variability thiab connector- cuam tshuam tsis ua hauj lwm. Rau cov neeg sib koom ua ke thiab cov neeg cog lus, qhov no txhais tau tias kev teeb tsa sai dua, cov cuab yeej siv tsawg dua hauv lub tsheb thauj khoom, thiab kev sib raug zoo, rov ua dua tshiab uas dhau qhov kev lees paub thawj zaug.

Tag nrho - Huab cua ua haujlwm kub

Tsim nyog rau -40 txog +85℃kev khiav hauj lwm qhov kub thiab txias, qhov splitter no tiv taus qhov hnyav tshaj ib puag ncig yam tsis muaj kev ua haujlwm drift.

 

Txias- huab cua xa tawm nyob rau sab qaum teb huab cua, suab puam kev teeb tsa nrog lub hnub kub kub, thiab cov chaw muaj kev lag luam nrog thermal cycling tag nrho cov txiaj ntsig los ntawm cov khoom tsim kho kom muaj kev ruaj ntseg dav dav.

 

Kub-dependent poob (TDL) yog tuav kom tsawg dua lossis sib npaug li 0.5 dB thoob plaws tag nrho, kom ntseeg tau tias qhov sib txuas ntawm cov npoo suav ntawm kev ua haujlwm tseem siv tau thoob plaws lub caij hloov pauv thiab ntau xyoo ntawm kev pabcuam lub neej.

Connectivity Solutions & Network Topologies

Muab tso rau hauv PON/FTTx Topologies

 

product-800-800

Nyob rau hauv ib tug raug GPON los yog EPON network, qhov kho qhov muag kab davhlau ya nyob twg (OLT) nyob rau hauv lub hauv paus chaw ua hauj lwm generates downstream signals nyob rau hauv 1260-1650 nm wavelengths.

Cov teeb liab no hla dhau feeder fiber ntau mus rau thawj -theem splitter (xws li qhov no 1 × 2 module), uas faib lub hwj chim kho qhov muag mus rau hauv kev faib tawm.

Txhua txoj hauv kev tuaj yeem txiav tawm ntawm cov splitters ntxiv lossis txuas ncaj qha mus rau qhov chaw kho qhov muag (ONTs/ONUs) ntawm cov neeg siv khoom.

Upstream signals los ntawm ONTs yog lub sij hawm- faib multiplexed thiab ua ke rov qab los ntawm cov splitters mus rau OLT.

Centralized Split Architecture

 

Nyob rau hauv centralized split designs, ib tug siab - ratio PLC splitter (xws li 1 × 32 los yog 1 × 64) yog muab tso rau hauv lub hauv paus chaw ua hauj lwm, headend khoom chav tsev, los yog lub ntsiab faib ncej, ncaj qha pub rau tag nrho cov neeg los ntawm ib qhov chaw.

Lub blockless 1 × 2 splitter ua haujlwm ua thawj - theem sib cais hauv kev teeb tsa cascaded, qhov twg OLT cov zis tau muab faib ua ob txoj hauv kev pub zaub mov. Txhua txoj kev ces txuas mus rau lwm qhov sib cais (piv txwv li, 1 × 16 lossis 1 × 32) nyob rau hauv tej thaj chaw deb hubs los yog txoj kev txee.

Qhov topology no txo ​​qis tus naj npawb ntawm cov chaw nres nkoj uas xav tau ntawm OLT chassis, ua kom yooj yim ntawm kev tswj fiber ntau ntawm lub taub hau, thiab tso cai rau cov tswv lag luam kom nthuav dav ntxiv kev faib tawm raws li cov neeg siv suav suav loj hlob - tag nrho thaum tuav cov kab ntshiab - ntawm - pom kev daws teeb meem thiab lub sij hawm kho qhov muag - OTDR (OTDR) reflectometry kuaj.

product-800-800

Distributed Split Architecture

 

product-800-800

Distributed splitting qhov chaw qis dua - ratio splitters (xws li 1 × 2, 1 × 4, los yog 1 × 8) los ze zog rau cov neeg siv kawg - feem ntau nyob rau hauv cov zej zog aggregation thawv, tsev hauv qab daus vaults, los yog pem teb faib vaj huam sib luag - nrog zaum kawg -stage splits (1 × 8, 1 × 50) txoj hauj lwm cov neeg sau npe.

Txoj hauv kev no txo ​​qis cov khoom noj fiber ntau suav los ntawm lub chaw ua haujlwm hauv nruab nrab, txo qis tag nrho cov kev nkag mus los ntawm kev ua kom luv luv ntawm ib tus neeg fiber ntau txuas, thiab ua rau cov neeg siv khoom hloov pauv hloov pauv yam tsis muaj kev cuam tshuam txog cov khoom siv hluav taws xob.

Lub blockless 1 × 2 splitter ua tau zoo nyob rau hauv lub luag hauj lwm no: nws compact form factor fits seamlessly rau hauv me me enclosures, pre-tawm connectors cia ceev cross-txuas mus rau subscriber poob cables, thiab tsawg poob khaws nyiaj txiag rau cov seem cascade theem.

Rau cov tsev kawm ntawv cov tes hauj lwm, cov chaw zov me nyuam, thiab kev lag luam POL kev xa tawm, kev faib tawm muaj kev hloov pauv hloov tau, kev daws teeb meem hauv cheeb tsam, thiab yooj yim dua yav tom ntej muaj peev xwm nthuav dav.

Daim ntawv thov Scenario

 

FTTx & FTTH Access Networks

Lub blockless 1 × 2 splitter ua haujlwm ua thawj - theem sib cais hauv fiber ntau- rau - lub - kev xa tawm hauv tsev, faib ib qho OLT tso tawm rau hauv ob txoj kev pub khoom noj rau cov zej zog sib txawv lossis cov tsev sib txawv. Cov neeg ua haujlwm tau txais txiaj ntsig los ntawm kev txo qis OLT chaw nres nkoj, kev tswj xyuas cov khoom noj kom yooj yim, thiab muaj peev xwm ntxiv cov kev sib cais thib ob raws li cov neeg xav tau loj hlob.

PON-Based Campus Networks

Cov tsev kawm ntawv qib siab, cov tsev kawm ntawv koom nrog, thiab ntau- cov tsev neeg xauj tsev siv GPON lossis EPON rau kev sib koom ua suab sib koom ua ke-cov ntaub ntawv- cov kev pabcuam video siv 1 × 2 splitters ntawm lub tsev cov ntsiab lus nkag lossis hauv pem teb aggregation nodes. Lub compact mini module tsim haum rau hauv cov chaw sib txuas lus uas twb muaj lawm, ntsug cable risers, thiab cov khoom siv racks yam tsis tas yuav tsum tau txuas ntxiv kho vajtse.

Passive Optical LAN (POL)

Cov tsev tos qhua, tsev kho mob, tsoomfwv cov chaw, thiab cov tsev ua haujlwm loj uas siv POL architectures kom txo qis kev siv hluav taws xob, cabling complex, thiab cov khoom siv hauv chav tsev siv cov blockless splitters thoob plaws hauv cov txheej txheem cabling. Lub 1 × 2 configuration tso cai sib npaug load faib thoob lub tsev tis los yog pem teb.

Data Center Interconnects

Cov chaw zov me nyuam siv PLC splitters coj mus rhaub cov teeb liab kho qhov muag rau kev saib xyuas kev ua tau zoo, kev soj ntsuam raws tu qauv, thiab kev soj ntsuam kev ruaj ntseg yam tsis muaj kev cuam tshuam cov tsheb ntau lawm. Lub 1 × 2 splitter faib cov teeb liab, xa ib qho tawm mus rau cov khoom siv lo lus uas peb thiab lwm qhov los ntsuas cov cuab yeej lossis cov khoom siv kho qhov muag. Kev poob siab rov qab thiab qis PDL khaws cov teeb liab zoo.

CATV & RF Video Overlay

Cov neeg ua haujlwm cable muab kev pabcuam analog lossis digital video tshaj PON tes hauj lwm siv cov splitters los faib 1550 nm RF video overlay signals nrog rau cov kev pabcuam cov ntaub ntawv. Kev pab cuam dav dav (1260–1650 nm) thiab qis WDL kom pob tshab, cuam tshuam - xa video dawb. Lub blockless tsim tso cai kev koom ua ke rau hauv headend combining nodes.

Sab nraum zoov Fiber Distribution

Txoj kev - theem txee, ncej- mounted enclosures, thiab underground vaults tau txais txiaj ntsig los ntawm mini module qhov kev cog lus hneev taw thiab kev tsim kho rugged. Cov neeg ua haujlwm txhim kho tuaj yeem txhim kho lub tshuab hluav taws xob ncaj qha mus rau cov tais sib txuas siv cov hlua khi lossis cov nplaum nplaum, tshem tawm qhov xav tau ntawm cov khoom loj loj. Tag nrho - huab cua ntsuas ntsuas ntsuas kom ntseeg tau tias kev ua haujlwm ruaj khov.

Tsev Entry Enclosures

Ntau-cov tsev nyob (MDUs), cov tsev ua haujlwm, thiab cov tsev nyob siab-nce siv phab ntsa me me-mounted lossis flush-mount thawv rau pem teb- theem fiber ntau faib. Lub blockless splitter's 4 × 60 × 7 mm hneev taw ua kom qhov chaw siv tau zoo tshaj plaws hauv cov ntaub ntawv sib cog lus no, tso cai rau cov neeg tsim khoom ntim ntau qhov kev ua haujlwm rau hauv cov tsev me me, tsis tshua muaj kev cuam tshuam.

Kev xa tawm ib ntus

Rau kev nthuav tawm lub network sai, kev ua haujlwm rov qab los, lossis kev sib txuas ib ntus, lub ntsaws - thiab - ua si ntawm qhov ua ntej - txiav cov splitters ua kom nrawm nrawm. Cov neeg cog lus tuaj yeem sib cuam tshuam cov cuab yeej siv tau yooj yim OLT, cov chaw faib khoom ib ntus, thiab cov neeg siv khoom siv nrog cov cuab yeej tsawg thiab kev cob qhia.

Cov Khoom Siv Muaj

Kev lag luam ib puag ncig nrog cov xwm txheej hnyav tau txais txiaj ntsig los ntawm kev sib cais cov qauv tsim rugged thiab dav kub ntau. Lub blockless form factor fits rau hauv compact tswj txee, thaum khoov -insensitive fiber tuav nruj routing los ntawm cov khoom siv. Factory-tawm cov connectors kom ntseeg tau tias kev ua tau zoo hauv kev co-ib puag ncig.

product-800-800
Npaj kom Optimize Koj Network?

Paub txog cov txiaj ntsig ntawm peb cov blockless PLC fiber ntau splitter tshuab rau koj FTTx thiab PON xa tawm.

Cim npe nrov: Tuam Tshoj blockless plc splitter manufacturers, lwm tus neeg, Hoobkas

Xa kev nug