Down Lead Clamp

Xa kev nug
Down Lead Clamp
Paub meej
Khoom nta
Lub DIMI FIBER Down Lead Clamp yog tsim los coj kev ruaj ntseg thiab tiv thaiv ADSS thiab OPGW cables raws tus ncej thiab cov kav xa hluav taws xob, los ntawm kev ncua mus rau hauv av lossis splice lub thawv. Nws lub cushioned clamping tsim faib lub siab sib npaug, tiv thaiv kev puas tsuaj ntawm cable los ntawm kev co, puas, thiab cua- ntxias txav hauv qhov hnyav sab nraum zoov.
Kev cai Specifications
Clamp qhov ntau thiab tsawg tuaj yeem hloov kho rau qhov sib txawv ADSS / OPGW txoj kab uas hla, nrog rau kev xaiv rau ib leeg lossis ntau lub cable khiav ntawm tib tus ncej lossis ntau lub ntsej muag. Ntau yam ntaub ntawv thiab mounting interfaces (ncej bands, ntauwd brackets, bolts) ntxiv rau OEM / ODM branding (logo, labels, ntim) muaj nyob rau kom phim cov nqi hluav taws xob thiab cov qauv tsim.
Ntawv pov thawj & Zoo
Tsim nyob rau hauv ISO-raws li kev tswj hwm zoo, DIMI FIBER Down Lead Clamps raug sim rau cov neeg kho tshuab tuav lub zog, plam tsis kam, UV stability, thiab kev ua haujlwm corrosion. RoHS/REACH-cov kev xaiv ua raws thiab cov ntaub ntawv txhawb nqa kev xeem muaj los txhawb kev pom zoo tsim thiab kev lees txais.
Qhov tseem ceeb ntawm cov khoom siv kho vajtse no ua kom ntseeg tau qhov chaw ntawm cable los ntawm cov qauv siab mus rau splice thawv thiab cov khoom siv davhlau ya nyob twg, tiv thaiv kev puas tsuaj los ntawm ib puag ncig kev ntxhov siab thaum tswj cov teeb liab kev ncaj ncees thoob plaws hauv kev sib txuas lus.
Peb cov hlau lead hauv qab ua ke ua ke cov khoom siv qib siab engineering nrog rau thaj chaw -cov qauv tsim pov thawj kom xa cov kev ua tau zoo tshaj plaws hauv kev xav tau kev siv vaj tse. Lub kaw lus zoo txo ​​cov kev txav ntawm cable los ntawm cua-vim kev co, tiv thaiv kev puas tsuaj, thiab tswj kom muaj qhov sib txawv ntawm cov kab sib txuas kom zoo thoob plaws hauv txoj kab ntsug.
Kev faib tawm yam khoom
ADSS Fiber Optic Cable Kho vajtse
Share to
Hauj lwm lawm

Vim li cas thiaj xaiv DIMI Down Lead Clamp?

 

Universal Cable Compatibility

Haum rau fiber ntau optic cables xws li 0.25 "mus rau 1.00" (6.35mm txog 25.4mm) nyob rau hauv txoj kab uas hla los ntawm intelligently tsim cushioning systems uas hloov mus rau ntau yam cable configurations tsis muaj kev cuam tshuam tuav lub zog.

Advanced Cable Protection

Huab cua-resistant polyurethane cushions thiab precision-engineered grooves tshem tawm cov ntsiab lus- loading stress on optical fibers, ho txo ​​txoj kev pheej hmoo ntawm microbending poob thiab teeb liab degradation thaum tiv thaiv cable tsho los ntawm UV raug thiab mechanical hnav.

Rapid Installation System

Cov cuab yeej-kev tsim kho kom zoo ua rau ib leeg-tus neeg teeb tsa nyob rau hauv qis dua 5 feeb ntawm ib lub clamp, txo cov nqi zog txog li 40% piv rau cov tshuab mounting ib txwm. Txhaum-Tom ntej torque bolts kom ntseeg tau tias kev txhim kho zoo ib yam ntawm ntau tus kws tshaj lij.

Multi-Structure Versatility

Comprehensive adapter kit system txhawb kev teeb tsa ntawm cov ncej ntoo, cov pob zeb ua vaj tse, steel lattice towers, thiab cov ncej hlau tsis muaj kev hloov kho lossis cov cuab yeej tshwj xeeb drilling, ua kom cov khoom lag luam tswj xyuas thiab xa tawm kev xa tawm.

Extended Service Life

Kub-dip galvanized steel Cheebtsam thiab UV-stabilized elastomers xa 25+ xyoo kev pab cuam lub neej nyob rau hauv hnyav tej yam kev mob, los ntawm suab puam tshav kub mus rau arctic txias, tuav ib tug clamping quab yuam nyob rau hauv cov khoom lifecycle.

Superior Performance

Nrog ISO 9001: 2015 ntawv pov thawj thiab ua raws li cov qauv kev sib txuas lus thoob ntiaj teb, DIMI Fiber muab cov neeg ua haujlwm sib txuas lus, cov tuam txhab siv hluav taws xob, thiab cov neeg ua haujlwm sib koom ua ke nrog kev daws teeb meem.

Technical Specifications

Khoom kos duab

product-700-700
product-700-700
product-700-700

Cable Compatibility Matrix

Qauv Code Cable Diameter Range Tej kev siv Qhov hnyav
DIMI-DLC-B3 0.301" - 0.400" (7.6 - 10.2 hli) Cov kab me me ADSS, Sab hauv / Sab nraum zoov cables 0.85 lbs (0.39 kg)
DIMI-DLC-B4 0.401" - 0.500" (10.2 - 12.7 hli) Txheem ADSS, Lub teeb -lub luag haujlwm OPGW 0.90 lbs (0.41 kg)
DIMI-DLC-B5 0.501" - 0.600" (12.7 - 15.2mm) Nruab nrab ADSS, Standard OPGW 0.96 lbs (0.44 kg)
DIMI-DLC-B6 0.601" - 0.700" (15.2 - 17.8 hli) Heavy-duty ADSS, Loj OPGW 1.02 lbs (0.46 kg)
DIMI-DLC-B7 0.701" - 0.800" (17.8 - 20.3 hli) Ntxiv -OPGW loj, Bundled cables 1.08 lbs (0.49 kg)
DIMI-DLC-B8 0.801" - 0.900" (20.3 - 22.9 hli) Hnyav OPGW, Ntau lub cable khiav 1.15 lbs (0.52 kg)
DIMI-DLC-B9 0.901" - 1.000" (22.9 - 25.4 hli) Qhov loj tshaj plaws OPGW, Cov ntawv thov tshwj xeeb 1.22 lbs (0.55 kg)

Mechanical Performance Data

Parameter Specification Test Standard
Yam tsawg kawg swb zog >100 lbs (445 N) ASTM D 4567 Cov khoom lag luam
Maximum Clamping Force 150 lbs (668 N) Sab hauv raws tu qauv
Cable Compression txwv <5% diameter reduction IEC 60794-1-2: Cov
Kev vibration Dampening 65-75% attenuation CIGRE TB-324
Installation Torque 45 -50 ft-lbs (61-68 Nm) Hoobkas calibrated
Kub Cycling -40℃rau +85℃(-40℃F txog +185℃F) ASTM D 1149 Cov khoom siv
UV Resistance 5000 teev tsis muaj degradation ASTM G 154 1
Ntsev Txau Resistance 2000 teev tsis muaj corrosion ASTM B117

Khoom Specifications

Cheebtsam Khoom siv Standard / Qib Kev kho mob
Cable Cushions Polyurethane elastomer Ntug A 85 ± 5 UV ruaj khov
Base Vaj Aluminium alloy 6061-T6 Anodized Hom II
Ntauwd Brackets Cov pa roj carbon steel ASTM A36 Kub-dip galvanized (ASTM A153)
Mounting Bolts Hlau alloy Qib 5 (SAE J429) Zinc plated
Txiav -Tawm Bolts Cov pa roj carbon steel Torque-calibrated Zinc -nickel coated
Ncej Banding Stainless hlau Type 304 Passivated
Fasteners Stainless hlau 18-8 Series Corrosion resistant

 

Khoom nta & Technical Advantages

Kev tsim qauv zoo tshaj plaws

 

Ob -Piece Modular Architecture

Lub down lead clamp nta lub hauv paus sophisticated - thiab -cap configuration nrog rau kab sib txuas kab grooves machined kom meej tolerances. Qhov kev tsim no faib cov clamping quab yuam sib npaug thoob plaws lub voj voog ncig, tiv thaiv kev ntxhov siab hauv cheeb tsam uas tuaj yeem ua rau cov fibers puas lossis cuam tshuam lub tsho cable kev ncaj ncees.

Tuav-Away Torque Control System

Lattice ntauwd adapters suav nrog lub Hoobkas- ntsuas qhov sib tsoo- deb ntawm cov ntsia hlau uas tawg ntawm qhov tseeb 45-50 ft-lbs (61-68 Nm), tshem tawm qhov txaus ntshai tshaj qhov txaus ntshai thiab ua kom muaj kev txhim kho zoo ib yam thoob plaws ntau qhov chaw thiab qib kev txawj ntse.

Anti-Txoj kev ntsuas qhov ntsuas qhov ntsuas

Ntauwd mounting brackets feature ua ke los tiv thaiv - kev sib hloov tabs thiab dual -bolt anchoring systems uas tiv thaiv clamp tsiv teb tsaws thaum lub sij hawm siab - cua xwm txheej los yog cable tensioning ua hauj lwm, tswj kev sib raug zoo specifications nyob rau ntau xyoo ntawm kev pab cuam.

Cov cuab yeej -Kev nkag rau Cable Dawb

Hinged cap tsim nrog tus kheej -aligning guide pins tso cai rau ib qho -kab cable tso, txo lub sij hawm installation thiab txo qis tuav cable uas tuaj yeem qhia kev ntxhov siab lossis kis kab mob thaum xa mus.

 

Material Engineering & Durability

 
01.

Huab cua-Resistant Polyurethane Cushions

FDA-raws li polyurethane formulation exhibits tshwj xeeb tiv thaiv UV degradation, ozone raug, thiab kub cycling ntawm -40℃rau +85℃(-40℃F mus rau +185℃F). Cov ntaub ntawv tuav cov Shore A hardness ntawm 85 ± 5 thoob plaws hauv 25 xyoo kev pab cuam lub neej.

02.

Kub-Dip Galvanized Steel Cheebtsam

Tag nrho cov txheej txheem steel tau txais ASTM A153 Class B kub-dip galvanization muab qhov tsawg kawg nkaus 3.4 mil (86 micron) zinc txheej thickness. Cov txheej tiv thaiv no muab kev tiv thaiv corrosion zoo tshaj hauv cov ntug dej hiav txwv, kev lag luam, thiab siab - av noo ib puag ncig.

03.

Stainless hlau Banding System

Hom 304 stainless hlau banding straps tiv thaiv corrosion thiab tuav lub zog tensile tshaj 1,200 lbs (5,340 N) thoob plaws hauv cov khoom lag luam, kom ruaj ntseg ncej txuas txawm tias nyob rau hauv ib puag ncig hnyav loading.

04.

Tshuaj tiv thaiv

Polyurethane cushions tiv taus degradation los ntawm cov khoom muaj kuab paug, kua qaub nag (pH 3.5-5.5), ntsev tsuag, roj diesel, thiab cov tshuaj siv hluav taws xob, tswj cov khoom siv hauv cov khoom siv tshuaj lom neeg.

 

Application Scenario & Use Cases

 

Telecommunications Infrastructure

 

product-700-700

Kev sib txuas hauv nroog hauv nroog: FTTH / FTTX kev xa tawm xav tau cov kab ntsug ntsug routing los ntawm huab cua cog rau hauv av- theem kev pabcuam terminals

Kev nthuav dav nyob deb nroog: Ntev - ncua ADSS kev teeb tsa ntawm cov ncej hluav taws xob nrog cov nqes ntsug kom nkag mus rau cov ntsiab lus

5G wireless backhaul: Siab -fiber- suav OPGW cables txuas macro cell chaw thauj mus los network infrastructure

Inter-tsim kev sib txuas: Tsev kawm ntawv cov tes hauj lwm nrog cov dav hlau xaim hluav taws xob xav tau ntau txoj kev hloov ntsug

Hu rau tam sim no

 

Hluav Taws Xob Hluav Taws Xob Networks

 

Kev sib txuas lus ntse daim phiaj: OPGW kev koom ua ke ntawm kev sib kis yees rau SCADA, kev tiv thaiv, thiab kev saib xyuas

Distribution automation: ADSS cables ntawm tis ncej txhawb kev hloov pauv thiab saib xyuas cov khoom siv

Kev sib txuas ntawm substation: Fiber txuas ntawm substations xav tau ntauwd- mus rau - hauv av cable routing

Cov chaw siv hluav taws xob tauj dua tshiab: Cua ua liaj ua teb thiab cov chaw siv hnub ci kev sib txuas lus nrog cov qauv sib txawv

Hu rau tam sim no

product-700-700

 

Daim Ntawv Thov Kev Lag Luam

 

product-700-700

Metropolitan 5G Small Cell Deployment

Qhov project Background

Ib qib-1 tus neeg siv xov tooj ntawm tes tau siv 450 lub xov tooj me me thoob plaws thaj chaw loj loj los muab 5G kev pab them nqi hauv siab -cov cheeb tsam nroog loj. Lub network architecture xav tau kev sib txuas ntawm fiber ntau rov qab los ntawm cov khoom siv hluav taws xob uas twb muaj lawm rau cov xov tooj cua tshiab me me uas tau nruab rau ntawm nruab nrab-ncej qhov siab (18-25 ko taw nce).

DIMI Solution Implementation

Pab pawg xa khoom tau teev tseg DIMI-DLC-B5-H1 down lead clamps nrog wood ncej hardware for standard 0.55 "inch ADSS drop cables. Installation crews mounted clamps at 1.5-meter intervals along vertical cable runs.

Nyob deb nroog Broadband Infrastructure Expansion

Qhov project Background

Kev koom tes hauv kev sib txuas lus hauv cheeb tsam tau pib ua $ 48 lab txoj haujlwm los txuas ntxiv gigabit fiber ntau rau 12,000 lub tsev nyob deb nroog thoob plaws 850 square mais ntawm thaj chaw ua liaj ua teb. Lub network tsim tau siv cov hluav taws xob sib koom tes uas twb muaj lawm nrog fiber ntau overlashed ntawm lub zog hluav taws xob faib hluav taws xob.

DIMI Solution Implementation

Cov pab pawg engineering xaiv DIMI-DLC-B6-H3 clamps (xiav, 0.601"-0.700") rau 0.65" txoj kab uas hla ADSS cables, siv steel ncej banding cov khoom sib dhos rau kev teeb tsa sai ntawm cov hlau puag ncig thiab cov ncej sib xyaw.

product-700-700
product-700-700

Electric Utility Smart Grid Integration

Qhov project Background

Lub chaw hluav taws xob hluav taws xob hauv cheeb tsam tau siv qhov kev tswj hwm kev faib tawm qib siab (ADMS) uas xav tau siab -bandwidth fiber ntau txuas ntawm 185 qhov chaw faib khoom thiab lub chaw ua haujlwm hauv nruab nrab. Qhov project koom nrog retrofitting OPGW cables mus rau 69kV thiab 138kV kis tau tus qauv uas twb muaj lawm.

DIMI Solution Implementation

Cov engineers tau teev DIMI-DLC-B7-T8 clamps (liab, 0.701"-0.800") nrog 8-inch lattice tower adapters rau 0.75" inch OPGW cables, suav nrog AS02 cov khoom siv rwb thaiv tsev rau kev tiv thaiv ib puag ncig siab.

International Airport Perimeter Network

Qhov project Background

Lub tshav dav hlau loj thoob ntiaj teb nthuav dav nws thaj tsam kev nyab xeeb thiab kev ua haujlwm network, xav tau kev sib txuas fiber ntau rau 156 qhov chaw nyob deb, suav nrog kev khiav teeb pom kev zoo, lub koob yees duab kev ruaj ntseg, ib puag ncig sensors, thiab chaw hu xov tooj thaum muaj xwm ceev faib thoob plaws 4,800 daim av.

DIMI Solution Implementation

Lub tshav dav hlau kev sib txuas lus tus neeg cog lus xa tawm DIMI-DLC-B5-H1 thiab DIMI-DLC-B6-H1 clamps rau sib xyaw 0.52 "thiab 0.68" txoj kab uas hla ADSS cables, xaiv ntoo ncej mounting ceev ceev thaum hmo ntuj tsim qhov rais.

product-700-700

 

Cov neeg siv khoom Testimonials & Reviews

 

Kev ntsuas tus neeg siv

Peb pab pawg tsim kho tau teeb tsa ntau dua 8,500 DIMI cia cov hlau lead clamps hla 340 mais ntawm kev nthuav dav nyob deb nroog hauv 18 lub hlis dhau los. Cov xim -coded sizing system tshem tawm qhov kev ntsuas qhov yuam kev uas ua rau peb cov khoom lag luam yav dhau los, txo qis kev ua haujlwm ntawm kwv yees li 85%.
 

Network Infrastructure Manager

Regional Telecommunications Provider

Kuv tau saib xyuas cov neeg ua haujlwm fiber ntau rau cov haujlwm loj hauv kev sib txuas lus txij li xyoo 2012, thiab kuv tuaj yeem ntseeg tau hais tias DIMI's down lead clamps yog cov installer tshaj plaws - cov khoom siv zoo nkauj uas kuv tau ntsib. Lub hinged cap tsim tso cai rau ib leeg -tus neeg teeb tsa yam tsis muaj juggling ntau yam khoom thaum tswj xyuas kom raug cable nruj.
 

Field Installation Supervisor

National Broadband Contractor

Peb cov khoom siv hluav taws xob ua haujlwm 3,200-mais fiber ntau optic network siv OPGW cables ntawm cov qauv sib kis xws li 69kV txog 345kV voltage theem. Peb xaiv DIMI cia cov hlau lead clamps rau kev nthuav dav hauv lub network loj uas muaj 95 lub chaw nres tsheb tom qab kev soj ntsuam cov khoom lag luam thiab kev sim kuaj.
 

Fiber Operations Engineer

Electric Utility Company

Cim npe nrov: Tuam Tshoj Down Lead Clamp manufacturers, lwm tus neeg, Hoobkas

Xa kev nug